Miele KM 342 User Manual

Installation Instructions
Gas Cooktop KM 342 KM 344
To prevent accidents and machine damage, read these instructions before installation or use.
®
UV
®
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
ß Do not try to light any appliance. ß Do not touch any electrical switch. ß Do not use any phone in your building. ß Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
ß If you cannot reach your gas supplier, call the
fire department.
– Installation and service must be performed by a
qualified installer, service agency or the gas supplier. (In Massachusetts a licensed plumber / gas fitter)
Note to the installer: Please leave this instruction book with the consumer for the local electrical / gas inspector’s use.
2
Contents
IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Appliance dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Setting the cooktop into place . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Securing the cooktop. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Gas connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Gas pressure regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Nominal Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Converting to another type of gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3
IMPORTANT SAFETY INSTRUCTIONS
Installation
The minimum distances given in these Installation instructions are to combustible surfaces, and must be observed to ensure safe operation. Failure to do so increases the risk of fire.
The cabinetry and venting hood should be installed first to prevent damage to the cooktop.
Gas appliances should only be installed in a well ventilated area.
The countertop must be bonded
with heat resistant (212 °F/100 °C) adhesive to prevent distortion or dissolving.
The cooktop should only be
installed as shown in the illustrations while maintaining the required safety distances shown. Do not install the cooktop between two tall cabinets, this is a fire hazard.
recommended
not recommended
a = indicates cooktop cut-out b = minimum distance between
cut-out and a tall cabinet: 12" (305 mm)
This appliance has not been
designed for maritime use or for use in mobile installations such as recreational vehicles or aircraft. However, under certain conditions it may be possible for installation in these applications. Please contact the Miele Technical Service Department with specific requirements.
4
not allowed
IMPORTANT SAFETY INSTRUCTIONS
The cooktop must not be installed
over a dishwasher, washer, dryer, refrigerator or freezer. Heat radiated by the cooktop may damage the appliances.
Deep fat fryers must not be
installed next to gas cooktops. Gas flames can ignite splattering oil. A distance of at least 12" (305 mm) should be maintained between these two appliances. The minimum distance between two cooktops must be 4" (100 mm).
Install the appliance so that the
power cord or gas piping does not come into contact with any portion of the cooktop which may become hot during use.
This appliance must be installed with its own shut off valve and the included gas pressure regulator. Both the valve and the regulator must be easily accessible to the consumer after the appliance is installed.
This appliance must be disconnected from the gas supply during any pressure testing of the system performed in excess of
1
/2psi (3.5 kPa). This appliance must be isolated at test pressures equal to or less than (3.5 kPa).
1
/2psi
Safety distances above the appliance
There must be a safety distance of at least 30" (760 mm), c between the appliance and any objects above it. The overhead cabinet depth, d, if unprotected, must not exceed 13" (330 mm). The minimum distance of combustible surfaces located above and to the sides of the cooktop, e, is 18" (457 mm).
If the cabinet manufacturer recommends a greater distance, follow that manufacturers recommendation.
When installing the cooktop under a venting hood, always observe the minimum distance recommended by the hood manufacturer.
Keep this instruction book in a safe place for reference and pass it on to any future user.
Any pipe connections must be made using a thread sealant approved for gas connections. Failure to correctly install these items could lead to a gas leak and subsequent explosion.
5
Appliance dimensions
KM 342
a Built-in depth KM 342 (stainless steel)
5
2
/16" (58 mm)
b Built-in depth KM 342 (black or white)
3
3
/8" (86 mm)
^
Rember to maintain the minimum safety distances to combustible surfaces:
3
- 2
/4" (70 mm) between the cut-out and the back wall and
- 12" (305 mm) between the cut-out and a side wall or tall unit to the right or left of the cut-out. (See "Important Safety instructions").
6
KM 344
Appliance dimensions
a Built-in depth KM 344 (stainless steel)
5
2
/16" (58 mm)
b Built-in depth KM 344 (black or white)
3
3
/8" (86 mm)
^
Rember to maintain the minimum safety distances to combustible surfaces:
3
- 2
/4" (70 mm) between the cut-out and the back wall and
- 12" (305 mm) between the cut-out and a side wall or tall unit to the right or left of the cut-out. (See "Important Safety instructions").
7
Installation
Setting the cooktop into place
d
c
^ After removing the protective
backing, d, stick the supplied seal, c, under the edge of the cooktop.
^ Screw the gas regulator onto the
nipple underneath the cooktop. (See "Gas Connection - Gas pressure regulator".)
^ Feed the power cord through the
cut-out to the power outlet.
Securing the cooktop
Secure the cooktop with the included
^
fixing bracket.
Countertop
Countertop 1
13
/16" (20 mm)
9
/16" (40 mm)
^
Set the cooktop in the cut-out and center it.
Install the appliance so that the power cord and gas piping does not come in contact with any portion of the cooktop which may become hot during use.
8
Important
The cooktop must not be permanently sealed into the countertop when installed. The sealing strip under the edge of the cooktop provides a sufficient seal.
If the cooktop is sealed into position, the countertop or appliance may be damaged if the cooktop needs to be removed for maintenance or service.
Installation
9
Electrical connection
This appliance must be electrically grounded according to local or national codes.
All electrical work should be performed by a qualified electrician in accordance with local codes and the:
- National Electrical Code
ANSI / NFPA No. 70 for the USA
or
- Canadian Electrical Code Part I
for Canada (CSA Standard C 22.1).
WARNING:
Disconnect the appliance from the main power supply before installation or service. To reduce the risk of electric shock, make sure that the appliance is properly grounded after installation.
Power supply:
This appliance is equipped with a three-prong grounding plug to prevent shock hazards. It should be plugged directly into a properly grounded outlet. Do not cut or remove the grounding prong from the plug. If the plug does not fit the outlet, have a proper outlet installed by a licensed electrician.
To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. It is imperative that this basic safety requirement be met. If there is any doubt, have the electrical system of the house checked by a qualified electrician. The manufacturer cannot be held responsible for damages caused by the lack, or inadequacy, of an effective grounding system.
The automatic ignition requires that the cooktop be connected to a 120 VAC, 60 Hz power supply. The supply line should be protected by a 15A fuse.
Actual power consumption (during ignition only) is 25W.
This appliance is equipped with a 4 ft. (1.2 m) long power cord that is ready for connection to the appropriate outlet.
Please place the power outlet so that it is accessible after the appliance has been installed in the countertop.
10
Note to the installer:
Please leave these instructions with the consumer or the appliance.
Wiring diagram
Electrical connection
11
Gas connection
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
In Massachusetts a licensed plumber / gas fitter is required.
This appliance must be installed with its own shut off valve and the included gas pressure regulator. Both the valve and the regulator must be easily accessible to the consumer to turn on or shut off the gas supply after the appliance is installed.
This appliance and its individual shut off valve must be disconnected from the gas supply during any pressure testing of the system performed in excess of
1
/2psi (3.5 kPa), or isolated from the gas supply line by closing its individual manual shut off valve at test pressures equal to or less than
1
/2psi (3.5 kPa).
The gas connection must be made in accordance with local codes or, in the absence of local codes, with:
- the National Fuel Gas Code, ANSI Z 223.1 / NFPA 54 for the USA.
or
- the current Can / CGA B 149.1 and .2 Installation Codes for gas burning appliances for Canada.
Any pipe connections must be made using a thread sealant approved for gas connections. Failure to correctly install these items could lead to a gas leak and subsequent explosion.
12
Gas connection
Make sure that the maximum gas supply pressure, before the gas pressure regulator, is never more than
1
/2psi for both natural gas or LP gas.
The minimum supply pressure to get the required gas input is: 6" w.c. for natural gas 10" w.c. for LP gas.
KM 342
11/16
2
(68mm)
KM 344
FRONT
FRONT
10
(269mm)
9/16
13
Gas connection
Gas pressure regulator
A pressure regulator that is convertible from natural to LP gas is included with the appliance. The included regulator corresponds with the gas type of the cooktop. Verify before installing.
The adjusted pressure is: natural gas - 4" w.c. LP gas - 10" w.c.
a Cooktop b ½" NPT c Regulator
For convenience, an AGA or CGA approved flexible stainless steel gas hose (accordion type) may be used between the gas connection and the regulator. This will allow the appliance to be lifted out of the countertop for cleaning or servicing. Make sure that any drawers, cabinet doors, etc., do not rub on this gas hose.
Do not use any regulator unless it has been supplied by Miele. Doing so may cause a gas leak.
If there is any doubt concerning installation contact the Miele Technical Service Department at:
U 1-800-999-1360
techserv@mieleusa.com
V 1-800-565-6435
service@miele.ca
After connecting the appliance check all fittings for gas leaks e.g. with soapy water.
As shown in the above diagram, the included regulator must be used when connecting the Miele cooktop to your gas supply. This item has been customized by Miele to meet all applicable safety requirements. Make sure the regulator is easily accessible for adjustment after the appliance has been installed.
14
When installed properly, the flame will be steady and quiet. It will also have a sharp, blue inner core that will vary in length proportional to the burner size. Flame adjustment will not be necessary.
Gas connection
Nominal Rating Table
KM 342 G KM 344 G
NG / LP-Gas NG / LP-Gas
Normal burner BTU/hr kW BTU/hr kW
Max. output 9000 2.6 9000 2.6
Min. output 1700 0.50 1700 0.5
Fast burner
Max. output 12000 3.5 12000 3.5
Min. output 2500 0.73 2500 0.73
Wok burner left
Max. output 15300 4.5 15300 4.5
Min. output 620 0.18 620 0.18
Wok burner right
Max. output 15300 4.5 16500 4.8
Min. output 620 0.18 620 0.18
All burners
Max. output 60600 17.7 73800 21.6
15
Converting to another type of gas
The cooktop should have been ordered for connection to either natural or LP gas (propane).
If the cooktop is not configured for the proper type of gas connection please contact your Miele Dealer.
161718
19
Alteration rights reserved / 0107
M.-Nr. 05 649 320 / 08
en - USA
Loading...