Miele DWF 956-4, DWF 9562-4 G, DWF 9564-4 GR, DWF 950-4, DWF 956-4 EX Operating instructions

...
Page 1
Operating and Installation Instructions
..............................................................................................................................
Cooker Hoods
DWF 956-4 DWF 9562-4 G DWF 9564-4 GR DWF 950-4 DWF 956-4 EX DWF 9562-4 G EX DWF 9564-4 GR EX
Q
Page 2
Contents
Contents
Caring for the environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Warning and Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Description of the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Brief description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Operation
Main switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
To switch the fan on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
To select a power level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Run-on option. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
To switch the fan off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
To switch the lighting on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
To dim the lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
To switch the lighting off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Filter operating hours counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Reading the filter operating hours counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Altering the filter operating hours counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Cleaning and care
Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Grease filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Charcoal filters: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Changing a halogen lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
After sales service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Appliance dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Assembly parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Connection for air extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Condensate trap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
External fans. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Page 3
Caring for the environment
Disposal of packing material
The transport and protective packing has been selected from materials which are environmentally friendly for disposal and can normally be recycled.
Ensure that any plastic wrappings, bags etc. are disposed safely and kept out of the reach of babies and young children. Danger of suffocation!
Caring for the environment
Disposal of your old appliance
Old appliances contain materials which can be reclaimed or recycled. Please contact your dealer, your local waste collection centre or scrap merchant about potential recycling schemes.
Ensure that the machine presents no danger to children while being stored for disposal.
Rather than just throwing these ma­terials away, please ensure they are of­fered for recycling.
See the appropriate section in the Warning and Safety instructions.
3
Page 4
Warning and Safety instructions
Warning and Safety instructions
This appliance conforms to current safety requirements. Incorrect use can lead to injury and damage to the appliance.
Before installation and before using for the first time read the operating instructions carefully. They contain important information on safety, use and maintenance of the appliance. This way you will avoid the risk of accidents and damage to the ap­pliance.
Keep these operating instructions in a safe place and pass them on to any future user.
Correct usage
The appliance is intended for do-
mestic use only. The manufacturer cannot be held re­sponsible for damage caused by im­proper use of the appliance.
Technical safety
the voltage and frequency details on the data plate correspond with the on­site electricity supply. This data must correspond in order to avoid risk of damage to the appliance. Consult a qualified electrician if in doubt.
when continuity is complete between the appliance and an effective earthing system which complies with local and national regulations. It is most import­ant that this basic safety requirement is tested by a qualified electrician. The manufacturer cannot be held respon­sible for the consequences of an inade­quate earthing system (e.g. electric shock).
qualified and competent persons to en­sure safety. Repairs and other work by unqualified persons could be dan­gerous and the manufacturer will not be held responsible.
Before connecting the appliance to the mains supply make sure that
The electrical safety of this ap­pliance can only be guaranteed
Installation work and repairs may only be carried out by suitably
This equipment is not designed for
maritime use or for use in mobile in­stallations such as caravans, aircraft etc. However it may be suitable for such usage subject to a risk assess­ment of the installation being carried out by a suitably qualified engineer.
4
Page 5
Warning and Safety instructions
The appliance is only completely isolated from the electricity supply
when: – it is switched off at the wall socket
and the plug removed. (Do not pull on the cable, only on the plug), or
– the fuse from the fused spur connec-
tion unit is withdrawn or, – the mains fuse is withdrawn, or – the screw-out fuse is removed in
countries where this is applicable.
Ensure power is not supplied to the appliance while maintenance
or repair work is being carried out.
Do not connect the appliance to
the mains electricity supply by an extension lead. Extension leads do not guarantee the required safety of the appliance, (e.g. danger of overheating).
Use
Do not let small children play with
the appliance or its controls or operate it. Supervise its use by the el­derly or infirm.
Never use an open flame beneath
the cooker hood. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the cooker hood could draw flames into the filter. Fat par­ticles drawn into the cooker hood pres­ent a fire hazard.
When using the cooker hood over
a gas hob ensure that any burners in use are always covered by a pan.
Otherwise flames could be drawn up by the suction of the cooker hood, parts of which could then be damaged.
Always switch the cooker hood on
when using the hob, otherwise con­densation may collect in the hood, which could cause corrosion.
When cooking with oil or fat, chip
pans and deep fat fryers etc, do not leave the pans unattended. Never leave an open grill unattended when grilling. Overheated oil and fat can ig­nite and could set the cooker hood on fire.
Do not use the cooker hood with-
out the grease filters in place. This way you will avoid the risk of grease and dirt getting into the ap­pliance and hindering its smooth oper­ation.
The filters should be regularly
cleaned, or changed, as appropri­ate. Saturated filters are a fire hazard.
Under no circumstances use a
steam cleaner to clean this ap­pliance. Pressurised steam could reach the electrical components and cause a short circuit.
In countries where there are areas
which may be subject to infesta­tion by cockroaches or other vermin, pay particular attention to keeping the appliance and its surroundings in a clean condition at all times. Any dam­age which may be caused by cock­roaches or other vermin will not be covered by the appliance guarantee.
5
Page 6
Warning and Safety instructions
Installation
The distance between the top of the cooker/hob and the bottom of
the cooker hood must measure at least: – 450 mm above electric hobs and
cookers
– 650 mm above gas hobs and
cookers
– 650 mm above an open grill from our
range
When fitted above an open grill the cooker hood must not be used in
recirculation mode. For non-Miele cooking appliances main-
tain the safety distance as recom­mended by the manufacturer in their In­stallation and Operating instructions.
If more than one appliance is fitted be­neath the cooker hood and they have different minimum safety distances to the cooker hood, select the greater dis­tance.
If exhaust air is to be extracted into
a chimney or ventilation duct no longer used for other purposes, seek professional advice.
Safety regulations prohibit the fit­ting of a cooker hood over solid
fuel stoves.
All ducting, pipework and fittings
must be of non-flammable ma­terial. These can be obtained from the Miele Spare Parts department or from builders’ merchants.
The appliance must not be con-
nected to a chimney or vent flue which is in use. Neither should it be connected to ducting which ventilates rooms with fireplaces.
6
Page 7
Warning and Safety instructions
When using the cooker hood in ex-
traction mode at the same time as another heating appliance which de­pends on the air in the room, (e.g. gas, oil or coal fired heaters, continuous flow or other water heaters, gas cooker, gas hob or gas oven) special care must be taken, as the action of the cooker hood extracts air from the room in which the appliance is installed and from neigh­bouring rooms, which these types of heater need for combustion.
They could also draw exhaust air back in from chimneys or ducting in con­travention of fire safety regulations.
In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the extractor and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
Ventilation can be maintained by air in­lets which cannot be blocked, in win­dows, doors and outside wall vents, or by other technical measures, such as ensuring that the extractor can only be switched on when the heating ap­pliance is switched off or vice-versa.
Appliances with external fans
For appliances with an external fan
motor fitted (EXT models) the con­nection of the two units must be made using the connection cable and the plug connectors. Make sure the correct combination of the two appliances has been selected. Separate instructions are supplied with the external fan.
Disposal of your old appliance
Before discarding an old ap-
pliance switch off and disconnect it from the power supply. Cut off and render any plug useless. Cut off the cable directly behind the appliance to prevent misuse. This should be done by a competent person.
The manufacturer cannot be held liable for damage caused by non­compliance with these Warning and Safety instructions.
N.B: The overall ventilation condition of the dwelling must be taken into ac­count. If in any doubt, the advice of a competent builder or, for gas, a “Corgi” installer must be sought.
If the cooker hood is operated in recir­culation mode (with active charcoal fil­ter) then the above restrictions do not apply.
7
Page 8
Description of the appliance
Description of the appliance
8
Page 9
Description of the appliance
Extension piece
b
Recirculation grilles
c
only with recirculation accessory kit
Tower
d
Canopy
e
Grease filters
f
Hob lighting
g
Controls
h
i Main switch
Touch control for the
j
run-on option
This control activates the run-on option. The fan is switched off automatically after either 5 or 15 minutes.
– to alter the number of hours counted
by the filter operating hours counter (see section "Operation / Altering the filter operating hours counter").
n Touch control for the
active charcoal filter
The indicator lamp for the active char­coal filter touch control lights up when the recirculation mode active charcoal filters need to be replaced.
The touch control is used: – to reset the operating hours counter
after replacing the active charcoal fil­ters (see "Cleaning and Care").
– to show how long the active charcoal
filters have been in use (see section on "Operation / Filter operating hours counter").
– to alter the number of hours counted
by the filter operating hours counter (see section "Operation / Altering the filter operating hours counter").
Touch control for the
k
grease filters
The indicator lamp for the grease filter touch control lights up when the grease filters need to be cleaned.
The touch control is used: – to reset the operating hours counter
after cleaning the grease filters (see "Cleaning and Care").
– to show how long the grease filters
have been in use (see section on "Operation / Filter operating hours counter").
m Touch control for
the hob lighting
This control switches the lighting on and off and is also a dimmer switch.
On/Off touch control
n
for the fan
Controls for setting the
o
fan power
9
Page 10
Brief description
Brief description
The cooker hood works with
. . . air extraction:
The air is drawn in and cleaned by the grease filters and directed outside.
The cooker hood is fitted with a non- return flap . This flap is closed when the cooker hood is switched off. No exchange of room air and outside air can take place. When the cooker hood is switched on the non-return flap opens for the cooking smells to be blown di­rectly outside.
. . . air recirculation:
(only with recirculation accessory kit) The air is drawn in and cleaned first by
grease filters and then cleaned by ac­tive charcoal filters. The cleaned air is then recirculated back into the kitchen through grilles in the top of the cooker hood extension piece.
Before using the cooker hood for the first time, ensure that the active charcoal filters are in place, see section on "Cleaning and care".
. . . an external fan:
(with EXT models) The EXT models are designed to be
connected to an external fan located outside the room.
10
The external fan is connected to the cooker hood by means of a control cable and is operated by the controls on the cooker hood.
Page 11
Operation
Operation
Main switch
Switch the main switch to "I". The fan and the lighting can now be operated.
If the appliance is not going to be used for a longer period of time (e.g. whilst on holiday) switch the appliance off by turning the main switch to "0".
The next time it is switched on the cooker hood will operate at the level previously used.
To switch the fan on
Press the On/Off touch control.
The fan runs at power level "lI". The indicator lamp comes on.
To select a power level
Depending on the intensity of cooking vapours, levels "I" to "III" (green indica­tor lamps) are usually sufficient for nor­mal cooking.
Intensive setting
When frying or cooking food with a strong aroma you may wish to select the Intensive setting (yellow indicator lamp) for a short period.
Run-on option
If the air still needs to be cleared after cooking, the cooker hood can be set to continue running. The fan is switched off automatically after either 5 or 15 minutes.
Press the run-on option touch control whilst the fan is still running.
Press once = The fan switches off
after 5 minutes. (left hand indicator lamp)
Press twice = The fan switches off
after 15 minutes. (right hand indicator lamp)
Press the – /+ controls to select the power level required.
Touch control + = higher setting Touch control – = lower setting
To switch the run-on option off, press the run-on option touch control again.
11
Page 12
Operation
To switch the fan off
Press the On/Off touch control to switch the fan off.
The indicator lamp goes out.
To switch the lighting on
The hob lighting can be switched on and off independently of the fan.
Briefly press the lighting touch con-
trol to switch on the hob lighting. The indicator lamp comes on. The lighting will come on at maximum
brightness.
To dim the lighting
The brightness of the lighting can be dimmed.
With the lighting switched on, press and hold the hob lighting control in. The brightness will gradually dim until you release the control.
Press the control in again to increase the brightness to the level required and then release it.
If you keep the control pressed in the brightness will continually go brighter and then dimmer.
To switch the lighting off
Briefly press the hob lighting control to switch the lighting off.
The indicator lamp goes out.
Safety cut-out
Should the cooker hood have been left switched on, the fan will switch off auto­matically after 10 hours. The lighting re­mains on.
12
Pressing the On/Off touch control will switch the fan back on again.
Page 13
Operation
Filter operating hours counter
The number of hours the appliance has been in operation is stored in memory.
The indicator lamp for the grease filter control will light up after 30 hours of operation. The grease filters must then be cleaned.
After the grease filters have been cleaned and put in place, the filter oper­ating hours counter must be re-set.
To do this, press the grease filter
touch control and hold for about 3
seconds.
The indicator lamp for the control will
go out. For recirculation mode the operating
hours counter needs to be set to the re­quired time.
Reading the filter operating hours counter
To check the percentage of time set al­ready used:
Use the On/Off touch control to switch the fan on.
Press the grease filter / active char­coal filter touch control.
One or several of the indicator lamps for the – /+ touch controls will flash.
The indicator lamp for the active char­coal filter control will light up after the cooker hood has operated for the num­ber of hours set. The active charcoal filters must then be replaced with new ones.
The filter operating hours counter must then be re-set.
Press the active charcoal filter touch
control for about 3 seconds.
The indicator lamp for the control will
go out.
The number of flashing lamps shows the percentage of the operating time which has already been used up.
1 lamp = 25 % 2 lamps = 50 % 3 lamps = 75 % 4 lamps = 100 %
The number of operating hours used re­mains in the memory, even when the appliance is switched off or there is a power cut.
13
Page 14
Operation
Altering the filter operating hours counter
You can set the operating hours counter to suit the type of cooking you do.
– Select a short time if you roast or fry
a lot. – If you use very little fat for cooking,
select a longer time. – If you only cook occasionally we re-
commend that you select a short
time because grease which has built
up gradually over a long period of
time will harden on the grease filters
and make cleaning more difficult.
Altering the grease filter operating hours counter
The operating hours counter for the grease filters is set at 30 hours. This can be lengthened or shortened. You can choose from 20, 30, 40 or 50 hours.
The indicator lamp for the grease filter touch control and one of the – /+ touch control lamps will flash.
The – /+ touch control lamps show the time which has been set: 1st lamp from the left = 20 hours 2nd lamp from the left = 30 hours 3rd lamp from the left = 40 hours 4th lamp from the left = 50 hours
Use the – /+ touch controls to select the desired time.
Confirm the selection by pressing the grease filter touch control.
If the procedure is not confirmed within 4 minutes of programming the steps, the cooker hood will auto­matically revert to the "old" data.
Press the On/Off touch control to
switch the fan off.
Press the run-on option touch control
and the grease filter touch control at
the same time.
14
Page 15
Operation
Setting/altering the active charcoal filter operating hours counter
(with recirculation mode) The charcoal filters are not used for
vented extraction. The cooker hood is set at the factory
for extraction mode, on delivery the operating hours counter for the active charcoal filters is set to unlimited.
For recirculation mode the operating hours counter needs to be set to the re­quired time:
Press the On/Off touch control to
switch the fan off.
The indicator lamp for the active char­coal filter touch control and one of the lamps for the – /+ touch controls will flash.
The – /+ touch control lamps show the time which has been set: 1st lamp from left = 120 hours 2nd lamp from left = 180 hours 3rd lamp from left = 240 hours 4th lamp from left = unlimited
Press the – /+ touch controls to se­lect the desired time.
Confirm the procedure by pressing the active charcoal filter touch con­trol.
Press the run-on option touch control
and the active charcoal filter touch
control at the same time.
If the procedure is not confirmed within 4 minutes of programming the steps, the cooker hood will auto­matically revert to the "old" data.
15
Page 16
Cleaning and care
Cleaning and care
Before any cleaning or maintenance work disconnect the cooker hood from the mains supply. Ensure that:
- it is switched off at the wall socket and the plug has been removed (do not pull on the cable, only on the plug), or – the fuse has been withdrawn from the fused spur connection unit, or
- the mains fuse is withdrawn, or
- the screw-out fuse is removed (in countries where this is applicable).
Housing
Warning: The surfaces and controls are susceptible to scratches and ab­rasion. Please observe the following cleaning instructions.
All external surfaces and controls
can be cleaned using warm water
with a little washing up liquid applied
with a well wrung out soft sponge or
cloth.
Wipe the surfaces dry using a soft
cloth.
Do not use too much water when cleaning the controls. Water could penetrate into the electronics and cause damage.
Glass surfaces can be cleaned
using a proprietary cleaning agent
for glass.
Avoid: – cleaning agents containing soda,
acids or chlorides,
– abrasive cleaning agents, e.g. pow-
der cleaners or cream cleaners, and abrasive sponges, e.g. pot scourers or sponges which have been used previously with abrasive cleaning agents. These will damage the surface ma­terial.
Stainless steel surfaces
Stainless steel surfaces can be cleaned using a proprietary non-ab­rasive cleaning agent designed specifi­cally for use on stainless steel.
To help prevent re-soiling, proprietary conditioning agents for stainless steel can also be used. Apply sparingly with an even pressure.
E-Cloth
A microfibre "E-Cloth" is available from the Miele UK Spare Parts Department, Part Number 98013530, which is suit­able for cleaning surfaces such as stainless steel, glass, plastic and chrome.
Stainless steel coloured controls
The controls may suffer discolour­ation or damage if soiling is left on them for too long. Remove any soiling straight away.
16
Do not use stainless steel cleaning agents on these controls.
Page 17
Cleaning and care
Grease filters
Re-usable metal filters are fitted which remove solid particles (oil, dust, etc.) from the kitchen vapours, preventing soiling of the cooker hood.
Always clean the filters as soon as the lamp for the grease filter touch control comes on.
The grease filters should be cleaned regularly to avoid a build-up of fat, (ap­prox. 3-4 weeks on average) but al­ways clean as soon as the grease filter touch control lamp comes on.
An over saturated filter is a fire ha­zard.
Clean the filters – by hand: with a nylon brush, warm water with a little washing up liquid. – in a dishwasher: place the filters with the short side upright in the lower basket, ensuring the spray arm is not obstructed.
Depending on the cleaning agent used, cleaning the grease filters in a dishwasher can cause permanent discolouration to the surface. However, this will not affect the func­tioning of the grease filters in any way.
After cleaning, leave the filters to dry on an absorbent surface before put­ting them back in place.
When removing the filters for clean­ing, also clean off any residues of oil or fat from the now accessible hous­ing to prevent the risk of these catch­ing fire.
To remove the grease filters pull the
quick-release catches.
Carefully remove the filters in a down-
wards direction.
After replacing the grease filters, press the grease filter touch control for approx. 3 seconds to re-set the operating hours counter. The indicator lamp for the control will go out.
If the grease filter is cleaned before the operating hours counter has reached its maximum, the grease fil­ter touch control should be pressed for approx. 6 seconds to reset the counter to zero.
17
Page 18
Cleaning and care
Charcoal filters:
(with recirculation mode)
If the cooker hood is connected for re­circulation, two active charcoal filters must be inserted in addition to the grease filters. These filters absorb nor­mal kitchen odours.
Active charcoal filters can be ob­tained from your dealer or the Miele spare Parts Department. Refer to the section "Technical data" for type and reference number.
Before fitting or replacing the active
charcoal filters, the grease filters
must first be taken out, (see previous
section for instructions on how to do
this).
The filters are supplied with fitting in­structions. Ensure these are carefully followed.
When fitting for the first time:
Set the operating hours counter to suit your requirements, (see “Oper- ation - Altering the filter operating hours counter”).
Always replace the filters as soon as the lamp for the active charcoal filter touch control comes on, or if they are no longer effective in absorbing kitchen odours. They should, however, be replaced at least every 6 months.
After fitting new active charcoal fil­ters, press the active charcoal filter touch control for approx. 3 seconds to re-set the operating hours counter. The indicator lamp for the control will go out.
If the active charcoal filters are re­placed before the operating hours counter has reached its maximum, the active charcoal filter touch con­trol should be pressed for approx. 6 seconds to reset the counter to zero.
18
Page 19
Changing a halogen lamp
Before any cleaning or maintenance work disconnect the cooker hood from the mains supply. Ensure that:
- it is switched off at the wall socket and the plug has been removed (do not pull on the cable, only on the plug), or – the fuse has been withdrawn from the fused spur connection unit, or
- the mains fuse is withdrawn, or
- the screw-out fuse is removed (in countries where this is applicable).
Exercise caution when changing ha­logen lamps. They get very hot dur­ing use and remain hot for some time after being switched off. Do not touch the surface directly when changing a lamp, as grease particles from your fingers will ad­here to the surface and damage it. Please follow the manufacturers in­structions
Cleaning and care
To change the halogen bulb, first remove the outer ring
Then detach the circlip c taking care that the glass out.
The halogen lamp e is fitted to a push-in connection socket. To re­place, pull out the old lamp and fit a new one.
Replace the cover d and press the circlip
Now replace the outer ring b.
carefully into the holder.
c
.
b
does not fall
d
Never use the lighting without the lamp cover ter designed to cut out harmful rays.
in place as it has a fil-
d
19
Page 20
After sales service
After sales service
In the event of any faults which you can­not remedy yourself, please contact:
– Your dealer or
– The Service Department
(see back cover for address). When contacting the Service Depart-
ment, please quote the model number and serial number of your appliance. These are shown on the data plate which is visible when the grease filters are removed.
Please note that telephone calls may be monitored and recorded to improve our service.
20
Page 21
Electrical connection
Electrical connection
All electrical work should be under­taken by a suitably qualified and competent person in strict accord­ance with national and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. The manufacturer can not be held responsible for unauth­orised work. Ensure power is not supplied to the appliance while installation or repair work is being carried out.
The cooker hood is supplied for con­nection to an a.c. 230 V single phase 50 Hz supply.
The voltage, rated load and fusing are given on the data plate. This is visible when the grease filters have been removed. Ensure that these match the household mains supply.
Connection should be made either by a double pole fused spur connection unit, or a fused plug and a suitable switched socket. The On-Off switch should be easily accessible after the appliance has been built in.
When switched off there must be an all­pole contact gap of 3 mm in the switch (including switch, fuses and relays ac­cording to EN 60 335).
If the socket is not accessible after in­stallation (depending on country) an ad­ditional means of disconnection must be provided for all poles.
For extra safety it is advisable to install a residual current device (RCD) with a trip current of 30 mA (in accordance with DIN VDE 0664, VDE 0100 Section
739). Do not connect via an extension lead.
Important UK
If the appliance is fitted with a non-re­wireable plug (BS 1363 UK) and the socket outlets are not suitable for the plug supplied, or if the existing plug needs to be replaced by a new one, the old plug will need to be cut off and an appropriate plug fitted. The fuse car­rier and the fuse should be removed from the old plug and disposed of. The plug cut from the cable should then be disposed of, and on no account be in­serted into any socket elsewhere in the house (electric shock hazard).
The fuse cover must be re-fitted when changing the fuse and if the fuse cover is lost the plug must not be used until a suitable replacement is obtained.
The colour of the correct replacement cover is that of the coloured insert in the base of the plug or the colour that is embossed in words in the base of the plug (as applicable to the design of plug fitted).
The correct fuse rating of the replace­ment fuses that are ASTA approved to BS 1362 should be fitted. Replacement fuse covers may be purchased from your local electrical suppliers or Ser­vice agent.
21
Page 22
Electrical connection
Important
The wires in the mains lead are col­oured in accordance with the following code:
Green/yellow = earth Blue = neutral Brown = live If the appliance is to be connected via
a plug and socket, please note the fol­lowing:
As the colours of the wires in the mains lead of this appliance may not corre­spond with the coloured markings identifying the terminals in your plug, proceed as follows:
The wire which is coloured green
and yellow must be connected to the
terminal in the plug which is marked
with the letter E or by the earth sym-
bol z or coloured green or green
and yellow.
The wire which is coloured blue must
be connected to the terminal which
is marked with the letter N or col-
oured black.
The wire which is coloured brown
must be connected to the terminal
which is marked with the letter L or
coloured red. For Australia / New Zealand: The wire
which is coloured brown must be con­nected to the terminal which is marked with the letter A or coloured red.
WARNING: THIS APPLIANCE MUST BE EARTHED
22
Page 23
Appliance dimensions
Appliance dimensions
Appliance height H
Recirculation mode
H = 820 1090 mm Extraction
H = 825 1000 mm
with extraction through the wall.
H = 770 – 1000 mm
with extraction through the ceiling.
Safety distance S above a cooker/hob
For safety reasons a minimum safe distance S must be maintained be­tween the top of the cooker / hob and the bottom of the cooker hood: – 450 mm above electric cookers / hobs
650 mm above gas hobs 650 mm above an open grill
from our range.
The shaded area represents the
wall or ceiling area for the vent cut­out, for feeding the connection cable through to an external fan and for fitting the connection socket. (For recirculation mode, the connection socket may only be fitted in a wall area).
Connection for air extraction ø 150 mm or ø 125 mm with reducing collar.
To fit the tower, distance A between the top of the tower and the ceiling must be at least 20 mm.
See Warning and Safety instruc­tions for further information.
When deciding dimension S please note that
– A distance of 650 mm above electric
cookers / hobs may be preferable to give more working space.
– If an Imperial rear wall panel is being
fitted, dimension S should be 700 mm.
– If the hood is fitted flush to the ceil-
ing, make sure that the height of cooker / hob + S + H is equal to but not greater than the floor to ceiling height of the room.
23
Page 24
Installation
Installation
Assembly parts
8 large headed screws, 5 x 40 mm
and 8 x S8 plugs for securing the retaining plates.
2 screws, 5 x 60 mm, 2 x S8R60 plugs for securing the ca-
nopy.
2 small headed screws, 5 x 40 mm, 2 x S8 plugs and 2 cover caps to give
the canopy additional stability.
2 screws, 3.5 x 9.5 mm for securing the motor unit.
4 screws, 3.9 x 7.5 mm for securing the tower and the extension piece.
2 hose clips for securing the exhaust ducting.
24
2 protective sheets for use when fit­ting the extension piece, 455 x 210 mm
Page 25
Retaining plates
There are three retaining plates A, B and C for fixing the cooker hood to the wall.
Before fitting, draw a vertical line centrally above the hob on the back wall.
Installation
Mark measurement S from the hob surface upwards. This marks the height of the lower rim of the cooker hood (see "Appliance dimensions").
Drill four 8 mm ø holes in the wall, as shown, and press S8 plugs into the holes.
First drill holes for attaching the canopy and for fitting retaining plate A.
Screw retaining plate A to the wall with 5 x 40 mm screws through both holes and use the two notches to help you align it with the centre line.
25
Page 26
Installation
Retaining plate B
Drill 4 further holes 8 mm ø through the now fitted retaining plate.
Press S8 plugs into the two upper holes and screw in two 5 x 40 mm large headed screws.
Press S8 R 60 plugs into the lower holes and screw in two 5 x 60 mm screws. Screw the bottom screws in only loosely so that they can later be used to secure the canopy.
Hold retaining plate B up to the wall and push up until directly below the ceiling. Use the notches to align it horizontally with the middle line. Mark the 2 drill holes on the wall.
Drill two, 8 mm ø holes into the wall, and push the S8 plugs into the holes.
Screw on the retaining plate with two 5 x 40 mm large headed screws.
Retaining plate C
Retaining plate C only needs to be fitted if dimension Y is greater than 400 mm. It provides additional stability for the extension piece.
At a maximum distance of 400 mm from the ceiling, hold retaining plate C against the wall and use the not­ches to align it with the middle line. Mark the two drill holes.
26
Page 27
Drill two 8 mm ø holes into the wall and press the S8 plugs into the holes.
Screw on retaining plate C with two 5 x 40 mm large headed screws.
Canopy
Before fitting the canopy, remove the grease filters (see "Cleaning and care").
Installation
Tighten the screws. In addition, also screw two
5 x 40 mm small headed screws into the holes provided inside the canopy.
Cover the holes in the canopy with the caps supplied.
Hang the canopy on the angle brackets and the two screws on re­taining plate A.
27
Page 28
Installation
Motor unit
(not for operation with an external fan)
With air extraction: If a non-return flap is not present in the venting system, the non-return flap supplied must be fitted into the exhaust connection in the motor unit. The flaps must open upwards.
The cooker hood is designed to take ø 150 mm exhaust ducting. If 125 mm ø exhaust ducting has to be used, the reducing collar needs to be fitted into the exhaust connec­tion on the motor unit. (see "Connection for air extraction").
With recirculation mode: Fit the reducing collar onto the ex­haust connection. The non-return flap is not required.
Hang the motor unit onto the hooks on the retaining plate.
Now secure the motor unit with the brackets on both sides of the retain­ing plate using 3.5 x 9.5 mm screws.
28
Page 29
Installation
Control unit
(only when operating with an external fan)
On EXT model cooker hoods the con­trol unit is fitted instead of the motor unit.
If 150 mm ø exhaust ducting has to be used, adapt the connection by cutting it off at the join with a sharp knife (see illustration). The exhaust connection does not need adapting if 125 mm ø ducting is being used.
Electrical connection
Connect the canopy connection cable to the corresponding coupling­s on the left and right of the motor unit or control unit.
Do this by connecting the four pole plug into the rear connection and the three pole plug into the front connec­tion of the coupling on the left of the motor unit or control unit.
Hang the control unit onto the hooks on the retaining plate and secure on both sides with the brackets on the retaining plate using 3.5 x 9.5 mm screws.
Connect the six pole plug into the coup­ling on the right of the motor unit or control unit.
Secure the cable with the cable holders (this does not apply to EXT models).
29
Page 30
Installation
If the cooker hood is to be con­nected to an external fan: Connect the control unit and the ex­ternal fan with the connection cable and the six pole plug.
Connect the appliance to the elec­tricity supply.
Before connecting the appliance read the safety notes in ”Warning and Safety Instructions and in the Electrical connection section.
Air extraction
Connect the vent ducting and se­cure to the exhaust connection with a hose clip.
Lead the top end to the open air through the wall or ceiling cut-out or to the external fan.
Proceed with the exhaust connec­tion. (see "Connection for air extraction").
30
Page 31
Recirculation
If site conditions are not suitable for the cooker hood to be used for air extrac­tion, the appliance can be connected for recirculation.
Installation
Push the directional unit on to the top retaining plate.
Secure the flexible hose supplied to the directional unit and to the reduc­ing collar on the motor unit using hose clips.
For this, a recirculation accessory kit, available as a special accessory from your dealer or the Miele Spare Parts De­partment must be used. Refer to the section "Technical data" for type and reference number.
Directional unit
b
Recirculation grilles
c
Flexible hose
d
Fixing strips for the
e
active charcoal filters:
Active charcoal filters
f
Fit the charcoal filters and set the fil­ter operating hours counter (see Cleaning and Care).
31
Page 32
Installation
Extension piece
An extension piece allows the cooker hood to be fitted at varying distances from the ceiling (see section "Appliance dimensions").
The extension piece has openings at each side. These are needed when the appliance is being used in recirculation mode (with the recirculation accessory kit fitted).
Recirculation Extraction
Bend the top hanging retainers ap­prox. 45° inwards. This makes fitting easier.
For recirculation, the extension piece is fitted with the openings at the top. For air extraction, the openings are not required. In this case, the extension piece is fitted with the openings at the bottom. They are then covered by the tower.
32
Recirculation Extraction
Pull the extension piece slightly out­wards and push over the upper re­taining plate.
For recirculation, make sure that the openings in the extension piece are po­sitioned at the same height as the air outlets in the directional unit.
Page 33
Screw the extension piece firmly to the upper retaining plate at each side with two screws 3.9 x 7.5 mm.
Only with recirculation mode:
Installation
Protective sheets for tower
The paper protective sheets protect the extension piece from being scratched when the tower is being fitted. They are removed when fitting is complete.
Fold the protective sheets at the top. Remove the protective foil around
the sticking points. Stick the protective sheets on to the
sides of the telescopic extension piece.
Fit the recirculation grilles into the ex­tension piece and into the directional unit behind so that the slats point downwards.
33
Page 34
Installation
Fitting the tower
Now secure the tower on both sides with two 3.9 x 7.5 screws.
Now hold the main tower gently apart and fit it over the extension piece.
Push the tower down approx. 1 cm into the canopy.
Adjust the tower. Remove the protective sheets by
pulling upwards.
34
Before using the appliance for the first time, take the grease filters out and remove the protective foil from the fitler frame.
Then replace the grease filters.
Page 35
Connection for air extraction
Connection for air extraction
Danger of toxic fumes. Please heed the Warning and Safety instructions to avoid the danger of toxic fumes.
The cooker hood should be in­stalled according to local building regulations. Seek approval from the building inspector where necessary.
– All ducting, pipework and fittings
must be of non-flammable material.
– The extraction ducting should be as
short and straight as possible.
– To ensure efficient air extraction the
diameter of the exhaust ducting should not be less than 150 mm.
If exhaust ducting with a diameter of less than 150 mm or flat ducting were to be used, the noise level of the cooker hood would increase and extraction would be less effi­cient.
Only reduce the diameter of the duct­ing if absolutely necessary, e.g. where narrower ducting has already been installed.
– Where ducting is horizontal it must
be laid to slope away at at least 1 cm per metre.
This is to ensure that condensate can­not drain back into the cooker hood.
– If the exhaust air is to be ducted into
the open air, the installation of a tele­scopic wall vent is recommended.
– If the exhaust air is to be ducted into
a vent flue, the ducting must be di­rected in the flow direction of the flue.
– Only use wide radius bends. Tight
bends reduce the air throughput of the cooker hood.
– Only use smooth pipes or flexible
hoses made from non-flammable ma­terials for extraction connection.
35
Page 36
Connection for air extraction
Important:
If the exhaust ducting is to run through rooms, ceiling space etc. where there may be great variations in temperature between the different areas, the prob­lem of sweating or condensation will need to be addressed. The exhaust ducting will need to be suitably insu­lated.
Condensate trap
In addition to insulating the exhaust ducting we recommend that a suitable condensate trap is also installed to collect and evaporate any condensate which may occur.
When installing a condensate trap ensure that it is positioned vertically and if possible directly above the exhaust connection.
36
Page 37
External fans
The types of appliance available are listed in the table below.
External fans
Fan type: Roof
ventilator
Model: DV 1100 DV 1005/1
Roof­ventilator
DV 1005/1G
Outside wall fan
AWG
1005/1
Outside wall fan
Extractor fan
Extractor fan (wall)
AWG 1100 ABLG 940/1 MG 1100
AWG
1005/1G
Dimensions: width mm depth mm height mm
Ø 301
244
380 460 230
380 460 160
Ø 301
124
360 400 245
310
280-390
390
Installed:
on flat roof
on pitched
X
X
roof on / in
X
X
X outside wall free choice
X
Air through­put: (unducted)
in practice * pipe con­nection
3
850 m
/h
3
/h
730 m
Ø 150 mm
3
950 m
/h
3
/h
780 m
Ø 150 mm/
125 mm
3
950 m
/h
3
/h
780 m
Ø 150 mm/
125 mm
3
850 m
/h
3
/h
730 m
Ø 150 mm
3
900 m
/h
3
/h
720 m
Ø 150 mm/
125 mm
850 m
730 m
Ø 150 mm
Nominal voltage: AC 220 /230 V 50 Hz
Motor output: 330 W 170 W 170 W 330 W 315 W 330 W
3
/h
3
/h
* Measured in the following built-in situation: cooker hood, 90° bend, 4 m extraction ducting, external fan.
N.B. Not all models are available in all countries. Consult your supplier for further details.
37
Page 38
External fans
External fan version
Installation:
Depending on the model involved, ex­ternal fans can be installed on an out­side wall, on a pitched roof or in a suit­able location indoors.
Model DV 1100 Model DV 1005/1 Model DV 1005/1G
– For installation on a pitched roof,
consult the roof tiler beforehand.
Model AWG 1100 Model AWG 1005/1 - 1005/1G
– Installation on an outside wall
First unscrew the sheet metal screws attached to the sides then remove the housing case.
Fit the flexible hose or exhaust duct on to the exhaust connection, and feed through a prepared opening in the wall, together with the power cable, and make connection with the hood. Then fix the fan to the wall. Put back the housing case and se­cure with the sheet metal screws.
the holes for the screws are to be drilled. Then drill the holes and insert plugs. Screw the housing together. Position the interior telescopic part and insert foam into the intervening space. Secure the stainless steel lid to the housing. Fit the extraction flexible hose and connect the cable connectors together, (if an extension is needed use the connection cable supplied).
Models ABLG 940/1
– Other suitable location
These fan units can be installed at any suitable location indoors and se­cured by means of the four holes drilled in the base plate. Connection to the hood as well as any possible extension behind the fan unit is like­wise made via a flexible hose or ex­haust duct.
Electrical connection:
Electrical connection is made by a power cable connecting the fan and the cooker hood, thus allowing the fan to operate at four different settings.
Model MG 1100
– Installation in an outside wall
Make a hole in the external wall as di­rected in the installation instructions for the wall fan. Remove the four fixing screws and take off the housing lid. Mark where
38
Separate fitting instructions are sup­plied with the external fan.
Page 39
Technical data
Rated load DWF 956-4, 9562-4 G, 9564-4 GR,
DWF 950-4, 956-4, 950-2. . . . . . 280 W
Lighting . . . . . . . . . . . . . . . . . 4 x 20 W
Voltage . . . . . . . . . . . . . . . . . . AC 230 V
Frequency . . . . . . . . . . . . . . . . ~ 50 Hz
Fuse rating . . . . . . . . . . . . . . . . . . . 13 A
Fan power
Extraction power according to EN 61591
Technical data
Extraction system ø 150 mm:
Level I. . . . . . . . . . . . . . . . . . . 220 m
Level II . . . . . . . . . . . . . . . . . . 335 m
Level III. . . . . . . . . . . . . . . . . . 440 m
Intensive level. . . . . . . . . . . . . 640 m
Extraction system ø 125 mm:
Level I. . . . . . . . . . . . . . . . . . . 210 m
Level II . . . . . . . . . . . . . . . . . . 305 m
Level III. . . . . . . . . . . . . . . . . . 405 m
Intensive level. . . . . . . . . . . . . 590 m
Unrestricted . . . . . . . . . . . . . . 690 m
Recirculation with charcoal filter:
Level I. . . . . . . . . . . . . . . . . . . 190 m
Level II . . . . . . . . . . . . . . . . . . 280 m
Level III. . . . . . . . . . . . . . . . . . 380 m
Intensive level. . . . . . . . . . . . . 570 m
Recirculation accessory kit: Imperial DULWF 95 Active charcoal filter: Imperial recirculation micro-filter DUMF 5
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
For EXT models, the rated load and ex­traction power will depend on the type of external fan fitted.
39
Page 40
imperial products are distributed in G. B. by:
Miele Co. Ltd, Fairacres, Marcham Road, Abingdon, Oxon OX14 1TW tel: (01235) 554455 imperial Office: tel (01235) 237782
M-No. 8 259 420 / 00- 2201 Alteration rights reserved.
Service Office: (01235) 554466 fax: (01235) 554477
+
s i m p l y u n i q u e
Loading...