Miele DGC 6705 XL Specification

ContourLine Plumbed Combi-Steam Oven
DGC 6705 XL
8mieleusa.com
ContourLine Plumbed Combi-Steam Oven DGC 6705 XL
DGC 6705 XL
Features:
• M Touch innovative and revolutionary controls are both easy-to-operate and navigate. An intuitive swipe of the screen will quickly lead you to your desired selection.
• MultiSteam technology delivers powerful external steam generation and optimum steam distribution via 6 inlet ports
• Plumbed water supply and drainage
• Wired roast probe for perfect roasting
• 3-in-1 appliance
1. True European convection oven
2. Steam oven
3. Combination of steam and convection oven
• MasterChef and MasterChef Gourmet menus offer over 150 food types to cook to perfection
• XL stainless steel cavity
• Lift up control panel conceals dishwasher-safe water container
• ComfortSwivel handle moves with the motion of your wrist, creating a more ergonomic feel when opening and closing the oven door
Page 2 of 15
ContourLine Plumbed Combi-Steam Oven DGC 6705 XL
SPECIFICATIONS
DGC 6705 XL — Item 23670552USA
Overall Unit Width - Excluding Fascia Dimension 21
Overall Height - Excluding Fascia Dimension 17
Overall Unit Depth - Excluding Fascia Dimension 21
Oven Door Clearance 13” (330mm)
Depth with door open 34
Overall Fascia Dimensions
Built-In
Minimum Cabinet Width 22
Minimum Cabinet Depth 21
Minimum Cabinet Opening Height 17
Minimum Base Support 60 lbs
Additional Cut-outs Required
Plumbing
Water Supply Requirements
9
/16” (548mm)
11
/16” (449mm)
5
/8” (550mm)
11
/16” (898mm)
7
23
/16” (595mm) W x 18” (455.5mm) H
7
/8” (22mm) D
x
1
/16” — 223/8” (560 - 568mm)
7
/8” (555mm)
11
/16” — 1713/16” (450 — 452mm)
Venting and plumbing cut-out required
11
19
/16” x 19/16” (500 x 40 mm)
Connect to a cold water supply only. Must be connected to a shut-off valve. The water shut-off valve must be accessible after installation. The water pressure must be between 14.5 psi (1 bar) and may not exceed 87.02 psi (6 bar). If the pressure is higher than 87.02 psi (6 bar), a pressure reducing valve must be installed. The supplied hose has a length of 59” (1500mm). The hose must not be shortened. The entire hose length must not exceed 24’7” (7.5m).
Drain hose loop may be positioned at or above the flood level of the sink or drain board to which it is connect to provide the
Drainage Requirements
proper air gap. The top of end the drain hose must not be higher than 19 where it connects to the drain trap. The drain
11
/16” (500mm) to
hose must not be shortened. The entire hose length must not exceed 24’7” (7.5m). See installation manual for additional information.
Supplied hose: flexible braided 4’11”
Plumbed Hose Connection
(1.5m) with GHT fitting for connection to a shut off valve.
Electrical
Electrical Requirements 240V 60Hz 20A
Power Cord Molded plug - NEMA 6-20, 240V power cord
Cut out for power cord Minimum 3” square
Electrical Rating 2.7kW (240V)
Total Amps 11.25A on 240V
Shipping
Shipping Weight 65 lbs
7
26
Shipping Dimensions
/32” (666mm) W x 215/8”(549mm) H x
231/16” (535mm) L
Support
Call 800.843.7231
20/20
82020technologies.com
Page 3 of 15
ContourLine Plumbed Combi-Steam Oven DGC 6705 XL
PRODUCT VIEWS
Isometric View
Front View
Page 4 of 15
ContourLine Plumbed Combi-Steam Oven DGC 6705 XL
PRODUCT VIEWS
Top View, Door Open
Side View
Page 5 of 15
Loading...
+ 10 hidden pages