36” Classic Wall Ventilation Hood
DA 399-7
Specification Sheets TRS 04242017
8mieleusa.com

36” Classic Wall Ventilation Hood
DA 399-7
SPECIFICATIONS
DA 399-7 — Item 28399750USA
Overall Unit Width 35
Overall Unit Height (Air Extraction) 27
Overall Unit Height (Recirculation) 32
Overall Unit Depth 20
Chimney Dimensions 11
Fan
Fan Speeds 4, Including Intensive setting
Maximum CFM
DA 399-7
FEATURES
• LED ClearView Lighting
• Front mounted backlit controls
• Four fan speeds (incl. intensive)
• Dishwasher-safe metal lters
• Polished stainless steel logo
• Stainless steel nish or RAL color options
Duct
Recommended Duct Diameter 6” (150 mm)
Electrical
Electrical Requirements 120 V, 60 Hz, 15 Amps
Power Cord Molded NEMA 5-15 plug, 2.5 ft (0.75m)
Shipping
Shipping Weight 55.3 lbs (25.1kg)
Support
Call Miele Customer Service 800.999.1360
Miele Website
20/20 Link
1
/4” (898 mm)
3
/8” — 40” (695—1015mm)
1
/2” — 451/16” (825—1145mm)
1
/2” (520 mm)
3
/8” (290mm) W x 105/8” (270mm) D
625 CFM, (Reducing Collar is available to
reduce Air flow to less than 400 CFM, more
information on page 8)
8www.mieleusa.com
82020technologies.com
Optional Accessories:
R2000
Reducing collar limits air
ow to less than 400 CFM
DUW 20
Installation kit for
recirculation mode
DKF12-900
OdorFree Charcoal lter
required accessory for
recirculation mode
DATK1-760
30” Chimney Extension
Specification Sheets TRS 04242017
DATK2-1000
40” Chimney Extension
DA 399-7
Page 2 of 8

36” Classic Wall Ventilation Hood
DA 399-7
PRODUCT VIEW
7:
7:
PLEASE NOTE: The majority of the weight of the installed ventilation system will be supported
by the lower retaining plate. It must be rmly attached to the stud framing behind the drywall.
If studs are not available in the required locations, a plywood backing (min. ½” (13 mm) thick)
spanning at least two studs must be installed. Failure to adequately support the weight as
stated may result in the ventilation system falling off the wall, causing personal injury and
property damage.
Specification Sheets TRS 04242017
DA 399-7
Page 3 of 8

36” Classic Wall Ventilation Hood
DA 399-7
INSTALLATION SPECIFICATIONS
Distance Between Cooktop and
Ventilation Hood (S)
DA 399-7
Specification Sheets TRS 04242017
Page 4 of 8

36” Classic Wall Ventilation Hood
DA 399-7
INSTALLATION SPECIFICATIONS
Recirculation Kit DUW 20
For Recirculation mode conversion kit DUW 20 is required.
DA 399-7
Specification Sheets TRS 04242017
Page 5 of 8

36” Classic Wall Ventilation Hood
DA 399-7
INSTALLATION SPECIFICATIONS
30” Wall Hood Chimney Extension
DATK1-760
DATK1-760:
L = 30” (760 mm)
Height H with chimney extension Kit:
H = Standard unit height + 111/4” (285 mm)
(1) Air outlet installed upwards for recirculation mode
DA 399-7
Specification Sheets TRS 04242017
Page 6 of 8

36” Classic Wall Ventilation Hood
DA 399-7
INSTALLATION SPECIFICATIONS
40” Wall Hood Chimney Extension
DATK1-1000
DATK2-1000:
L = 393/8” (1000 mm)
Height H with chimney extension Kit:
H = Standard unit height + 2011/16” (525 mm)
(1) Air outlet installed upwards for recirculation mode
DA 399-7
Specification Sheets TRS 04242017
Page 7 of 8

36” Classic Wall Ventilation Hood
DA 399-7
Reducing Collar
(Optional Accessory)
If you would like to reduce the enviromental impact of your ventilation
system by limiting the CFM output the Reducing Collar can be installed.
It reduces the air ow to less than 400 CFM. Check local building codes
for maximum CFM requirements.