Miele 398-5, 399-5 User Manual

0 (0)
Operating and Installation Instructions
Ventilation System DA 398-5 DA 399-5
To prevent accidents and appliance damage, read these instructions
before
en-US
M.-Nr. 07 759 400
2
Contents
IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Guide to the Ventilation System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Functional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Turning on the fan s ...............................................11
Selecting the power level - / + .......................................11
Overhead lighting I ...............................................12
Cleaning and Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cleaning the casing................................................13
Grease filters .....................................................14
Active charcoal filter ...............................................15
Changing the light bulb .............................................16
After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Caring for the environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Appliance dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Structural support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Installation instructions .............................................27
Protective film ....................................................27
Dismantling ......................................................27
Installation materials ...............................................28
Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Air extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3
IMPORTANT SAFETY INSTRUCTIONS
,WARNING
READ AND SAVE THESE INSTRUCTIONS
Keep these instructions in a safe place and pass them on to any future user.
Read these instructions carefully before installing or using the Ventilation System.
This appliance is intended for
~
residential use only. Use the appliance only for its intended purpose.
This appliance complies with current
~
safety requirements. Improper use of the appliance can lead to personal injury and material damage.
,CAUTION For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors.
This appliance is designed to vent
~
cooking smoke and odors only.
This appliance is suitable for
~
installation above gas or electric cooking surfaces.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this appliance only in the
~
manner intended by the manufacturer. If you have questions, contact Miele.
b) Before servicing or cleaning the
~
appliance, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. If the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
c) Be certain your appliance is
~
properly installed and grounded by a qualified technician. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. It is imperative that this basic safety requirement be met. If there is any doubt, have the electrical system of the house checked by a qualified electrician.
This appliance is not designed for
~
maritime use or for use in mobile installations such as recreational vehicles or aircraft. However, under certain conditions installation in these applications may be possible. Please contact your Miele dealer or the Miele Technical Service Department with specific requirements.
4
IMPORTANT SAFETY INSTRUCTIONS
d) Before connecting the appliance
~
to the power supply make sure that the voltage and frequency listed on the data plate correspond with the household electrical supply. This data must correspond to prevent appliance damage. If in doubt consult a qualified electrician.
e) Installation work and repairs
~
should only be performed by a qualified technician in accordance with all applicable codes and standards. Repairs and other work by unqualified persons could be dangerous.
f) Only open the housing as
~
described in the enclosed "Installation diagram" and in the "Cleaning and care" section of this manual. Under no circumstances should any other parts of the housing be opened. Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults.
g) Before discarding an old
~
appliance, disconnect it from the power supply and remove the power cord to prevent hazards.
Use
,WARNING TO REDUCE THE RISK OF A COOKTOP GREASE FIRE:
a) Never leave surface units
~
unattended at high settings. Boilovers cause smoking and greasy spillovers may ignite. Heat oils slowly on low or medium settings.
b) Always turn the hood on when
~
cooking at a high heat.
c) Clean the ventilation hood
~
frequently. Grease should not be allowed to accumulate on the fan or filter.
d) Use the proper pan size. Always
~
use cookware appropriate for the size of the cooking area.
e) Do not flambé or grill with an
~
open flame beneath the hood. Flames could be drawn up into the hood by the suction and the grease filters may catch fire.
5
IMPORTANT SAFETY INSTRUCTIONS
,WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING
a) SMOTHER FLAMES with a close
~
fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING
~
PAN - You may be burned.
c) DO NOT USE WATER, including
~
wet dishcloths or towels - a violent steam explosion will result.
d) Use a fire extinguisher ONLY if:
~
1) You have a class ABC extinguisher, and you know how to operate it.
*
:
Do not allow children to play with or
~
operate the appliance or its controls. Supervise its use by the elderly or infirm.
Always turn on the hood when using
~
the cooktop to prevent damage from condensation.
Never operate gas burners without
~
cookware. Turn the burner off when not in use. Adjust the burner so that the flames do not extend beneath the cookware. Do not overheat the cookware, e.g. when using a wok. The hood can be damaged due to excessive heat from the burners and the cookware.
Do not use the hood without the
~
grease filters in place.
Do not use a steam cleaner to clean
~
the hood. Steam could penetrate electrical components and cause a short circuit.
2) The fire is small and contained in the area where it started.
3) The fire department is being called.
4)You can fight the fire with your back to an exit.
*
Based on "Kitchen Firesafety Tips" published by NAFTA
6
IMPORTANT SAFETY INSTRUCTIONS
Installation
,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical
~
wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
b) Sufficient air is needed for
~
combustion and exhausting of gases through the flue (chimney of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into the
~
wall or ceiling, do not damage electrical wiring and other hidden utilities.
g) Do not install this hood over
~
cooktops that burn solid fuel.
h) Provided a larger distance is not
~
given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood given in the "Appliance dimensions" section of this manual.
If local building codes require a greater safety distance, follow their requirement.
If there is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance.
i) Never connect an exhaust hood to
~
an active chimney, dryer vent, vent flue, or room ventilating ductwork.
j) Seek professional advice before
~
connecting an exhaust hood vent to an existing, inactive chimney or vent flue.
k) Any fittings, sealant, or materials
~
used to install the ductwork must be made of approved non-flammable materials.
d) Ducted hoods must always be
~
vented to the outdoors.
e) Do not use this hood with any
~
solid-state speed control device.
f) Do not use an extension cord to
~
connect the appliance to electricity. Extension cords do not guarantee the required safety of the appliance, (e.g. danger of overheating).
,WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK.
7
Guide to the Ventilation System
8
a Telescopic extension piece
b Chimney
c Canopy
d Control panel
e Grease filter
f Recirculation vent
(recirculation mode only)
g Overhead lighting
h Charcoal filter
(optional accessory for recirculation mode)
i On/Off button
j Fan power selection
k On/Off button for the overhead
lighing
Guide to the Ventilation System
9
Functional description
The hood offers two modes of operation:
Air extraction
The air is drawn in and cleaned by the grease filters and directed outside.
The hood comes equipped with a non-return flap. This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur. When the hood is turned on, the air pressure of the exhaust fan automatically opens the flap blowing the inside air and cooking odors outside.
Recirculation mode
Air is drawn through the grease filters and an active charcoal filter. The filtered air is then recirculated back into the kitchen through a vent at the top of the hood’s chimney.
The recirculation mode requires an install kit and charcoal filter which are optional accessories.
Before using the hood in recirculation mode, ensure that the active charcoal filter is in place, see "Cleaning and care".
10
Operation
Turning on the fan s
Press the On/Off button s.
^
The fan turns on to Level "II".
Selecting the power level - / +
Press the "" symbol to select a lower
^
power level or the "+" symbol for a higher power level.
Depending on the amount of cooking odors, levels 1 to 3 are usually sufficient for normal cooking.
Intensive setting
Level "4" should only be used for short periods of time when frying or cooking food with a strong aroma.
Automatically switching back the intensive power level
The intensive level can be programmed to automatically switch back to level 3 after 10 minutes.
Turn the fan and the overhead
^
lighting off.
Press and hold the - and + buttons
^
for approx. 10 seconds until power level indicator 1 lights up.
Then press the following buttons one
^
after another :
– light I,
– the "–" button, and
– the light button I again.
If the indicators 1 and 4 flash, the automatic switch back is not activated.
^ To activate the automatic switch
back, press the "+" button. The power level indicators 1 and 4 light continuously. To deactivate, press the "–" button.
^
Press the On/Off s button to confirm the setting.
If the procedure is not stored within 4 minutes, the hood will automatically default to the original setting
11
Loading...