Midland BASE TECH III Operator's Manual

OPERATOR'S MANUAL
BASE TECH III BASE/REPEATER STATION
P25/ANALOG
December, 2006
NOTICE: The AMBE+2 ™ voice coding Technology embodied in this product is protected by intellectual property rights including patent rights, copyrights and trade secrets of Digital Voice Systems, Inc. This voice coding Technology is licensed solely for use within this Communications Equipment. The user of this Technology is explicitly prohibited from attempting to extract, remove, decompile, reverse engineer or disassemble the Object Code, or in any other way convert the Object Code into a human readable form. U.S. Patents Nos. #5,870,405, #5,826,222, #5,754,974 #5,701,390, #5,715,365, #5,649,050, #5,630,011, #5,581,656, #5,517,511, #5,491,772, #5,247,579, #5,226,084 and #5,195,166.
Attention: The antenna(s) used for this transmitter must be fixed-
mounted on outdoor permanent structures with a separation distance of
at least 6 meters from all persons during normal operation. The peak
conducted output power at each antenna terminal must not exceed 250
Watts and the peak radiated output power must not exceed 1000 Watts
EIPR. Users and inst allers must ensure that FCC requirements for
satisfying RF exposure compliance are met. (See FCC Rules Part 1,
Sections 1307 and 1310)
SECTION INDEX Page
1) LCD Display
2) LED Display
3) Key Controls
4) Programming
5) Volume Control
6) Squelch Control
7) LCD Backlight Dimmer
8) Selecting Channel
9) P-25 Squelch Control
10) P-25 PTT mode
11) P-25 Calling Selection
12) Individual Call
13) Group Name
14) Key Lock
15) Channel Status Data
16) P-25 Status Data
3 3 4 5 6 6 6 7 7 8
9 10 10 11 11 12
17) Bar Graph/ Channel Display
18) LCD Backlight Hold
19) Changing TX Power
20) Caller ID
21) Emergency Call Reception
22) Repeater Mode
23) Remote Control
24) P-25 Test Mode
25) Adjust Mode
26) Key Test
27) Displaying Firm Ware Version
28) Displaying Serial Num ber
29) Displaying Program Software Version
30) Data Check
31) Error Displays
32) Firmware Error Check
12 13 13 13 14 14 14
15-16
17 18 19 19 20 20 21 21
33) RS232C Error Detection
34) DSP Error Detection
21 22
Base Tech III Operating Manual
1
1) LCD Display LCD display consists of 4 x 20 characters as shown. Line 1 : Incoming RSSI with 10 steps Line 2: Output power levels with 10 steps Line 3: Left 4 letters show Channel Numbers. Middle 8 letters
show channel name (if not programmed, shows blank). Right 4 letters show status of the radio. 1/ RX mode : M= Mix, both analog and digital can be received
D= Only digital can be received.
2/ TX mode: D=PTT digital transmission
A=PTT analog transmission
3/ Monitor mode: X= Monitor off
S= Selective squelc h
4/ P-25 squelch: N= Normal squelch
S= Selective squelc h
5/ Key lock mode: =Key lock
6/ Shift mode: Depressing the SHIFT KEY (back to normal
after 2 seconds)
Line 4 : Left 2 letters .show GROUP CALL, ALL CALL, INDIVIDUAL CALL.
Right 18 letters show GROUP NAME, INDIVIDUAL NUMBERS, ETC.
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
1
RX = = = = = = = = = =
2
TX = = = = = = = = = =
3
C001 Channel MDXN
4
GP 500
2) LED Display BASE TECH III has 5 LED's, from the left ; DIGI= LED on when receiving digital si gna l REP= LED on when repeat mode. BASE TECH III can be programmed
SIMPLEX -SEMIDUPLEX - DUPLEX- REPEATER on a per channel basis ALM= LED flashing on when an error on either TX or RX occurs TX= LED on when in Transmit BUSY= LED on when carrier is present
Base Tech III Operating Manual
2
3) Key controls a/ Key entry without SHIFT key
0-9 : channel numbers and individual call address (target address) A: P-25 calls (Group call, All call, Individual call) B: The beginning and the end of individual call number C: No function D= P-25 mode (analog or digital) *= Cancel channel number, individual number #= Ending channel number, individual number CH= Channel number entry, depress CH, then 0-9 for channels F(Scan)= No function MON= monitor ON or OFF ' Rotary knob: Volume, Squelch, Back Light Dimmer level
b/ Key entry following to SHIFT key 0= P-25 test mode start and finish 1=back light ON/OFF 2=Tx power Hi/LOW 3=No function 4=No function 5=No function 6=No function 7=lndicating channel data 8=Key lock ON/OFF 9=No function A= No function B= No function C= No function D= No function *= Indicating P-25 data #=No function CH= Toggle Bar-Graph ON/OFF F(scan)= No function MON=P-25 squelch. normal or selective squelch
Base Tech III Operating Manual
3
4) Programming Base Tech III can be programmed through PC at anytime when RX mode. Programming is not possible while Base Tech III in key entry. When programming is started, the LCD indicates as shown. Figure-1 shows Data from radio to PC, Figure-2 shows Data from PC to radio. If the program software is not communicating properly, the radio will re-write again and again (endless). When this happens, keep depressing SHIFT and switch on the radio. Then the radio will recover. Figure-3 shows display when SHIFT+ POWER switch on.
<Data Programming>
<71BS V100 710>
Data Output
Figure 1.
<Data Programming>
<71BS V100 710>
Data Input
Figure 2.
<Data Programming>
<71BS V100 710>
Figure 3.
Base Tech III Operating Manual
4
5) Volume control
Push rotary knob, and then rotating the knob. Volume level varies from VOLO to VOL-34. Figure 4 shows VOL-12 level
RX = = = = = = = = = = TX = = = = = = = = = =
C001 Channel GP VOL - 1 2
Figure 4.
6) Squelch control
Push rotary knob to select Squelch. Squelch level varies from SQL-1 to SQL-15. Figure-5 shows SQL-9 level
RX = = = = = = = = = = TX = = = = = = = = = =
C001 Channel GP SQL - 9
Figure 5.
7) LCD backlight dimmer
Push rotary knob to select DIM. Dimmer level varies from DIM-0 to DIM-15. DIM-0 is the most darkest. Figure-6 shows DIM-5 level
RX = = = = = = = = = = TX = = = = = = = = = =
C001 Channel GP DIM - 5
Figure 6
Base Tech III Operating Manual
5
8) Channel Selection
BASE TECH III has capability of up to 500 channels. Press CH, and then 0-9 key for channel numbers Example:-1 CH-8
CH + 0 + 0 + 8 or CH + 8 + #
Example-2 CH-500
CH + 5 + 0 + 0
9) P-25 Squelch control Press SHIFT then MON to choose P-25 squelch mode. Normal SQ= If NAC is the same, then receiver will unmute Selective SQ= If NAC and GROUP is the same, then receiver will unmute
If radio is called with the correct individual number, then radio will unmute. Figure-7 shows Normal SQ, Figure-8 shows Selective SQ
RX TX
C001 Channel MDXN GP Normal SQL
Figure 7.
RX TX
C001 Channel MDXN GP Selective SQL
Figure 8
Base Tech III Operating Manual
6
10) P-25 PTT mode Press D to select PTT mode.
When PTT= analog, PTT transmits analog When PTT= digital, PTT transmits digital;
Figure-9 shows Analog Figure-10 shows Digital
RX TX
C001 Channel MAXN GP PTT is Analog
RX TX
C001 Channel MDXN GP PTT is Digital
Figure 9
Figure 10
Base Tech III Operating Manual
7
11) P-25 Calling selection
Press A to select GP= group call, AL= all call, ID= individual call Figure-11 shows group call 500=TGID (talk group ID) Figure-12 show all call, 65535=all call group TGID Figure-13 shows individual call
RX TX
C001 Channel MDXN
GP 500
Figure 11
RX TX
C001 Channel MDXN AL 65535
Figure 12.
RX TX
C001 Channel MDXN ID - - - - - - - - -
Figure13
Base Tech III Operating Manual
8
12) Individual call (target call) This function works only selected Individual call in Para-11 Press B, and enter 0-9 for individual numbers. Press B or # to complete entry. To clear, press * to erase the last entry. Figure-14 shows to start entry, pressing B Figure-15 shows to complete entry, 1 +2+3+4+5+B
RX TX
C001 Channel MDXN ID __
Figure 14.
RX TX
C001 Channel MDXN ID 1 2 3 4 5
Figure 15.
13) Group name If GP is selected, TGID name is indicated (Max 8 characters) Figure-16 shows POLICE for TGID name
RX TX
C001 Channel MDXN GP P O L I C E
Figure 16
Base Tech III Operating Manual
9
14) Key lock
SHIFT+8 = Key lock. This symbol shows on LCD
However, PTT, MON and SHIFT key are not locked. If you need to lock these 3 keys, then you may select in Programming software as DISABLE. If the station is to be remotely controlled it is recommended to leave PTT enabled, Remote PTT will not work when PTT is locked. To release key lock, press SHIFT+ 8 again. Figure-17 shows key locked Figure-18 shows key unlocked
RX TX
C001 Channel GP Key Lock
Figure 17
RX TX
C001 Channel GP Key Unlock
Figure 18
15) Channel status data Press SHIFT+7 shows the following modes, every 1.5 seconds to check modes when 7 is depressed.
1/ Rx width (narrow/wide/4khz) 2/ TX width (narrow/wide/4KHz) 3/ Base mode (Simplex/Semi-duplex/Duplex/Repeater) 4/ Rx CTCSS/DCS, CTCSS and DCS are used in Rx 5/ TX CTCSS/DCS, CTCSS and DCS are used in TX However, these functions must be enabled in software at MISCELLANEOUS menu; INFORMATION DISPLAY-ENABLE Figure-19 shows SHIFT+ 7 indicating narrow channel.
RX TX
C001 Channel RX Narrow Channel
Figure 19
Base Tech III Operating Manual
10
16) P-25 Status data Press SHIFT+* shows the following modes, every 1.5 seconds to move when * is depressed. 1/ Unit ID (source address) 2/ RX NAC 3/ TX-NAC 4/ TGID However, these functions must be enabled in software at MISCELLANEOUS menu; INFORMATION DISPLAY-ENABLE
Figure 20 shows SHIFT+* indicating Unit ID code
RX TX
C001 Channel Unit ID 1 1 9 3 0 4 6
Figure 20
17) Bar Graph/ Channel Display Press SHIFT+CH to eliminate bar graph. In turn, current working frequencies are shown on LCD. Press SHIFT + CH to toggle back Figure-21 shows SHIFT+CH to indicate TX and RX frequencies. “RXWS” indicates RX is Wide band, Simplex mode and “TXN” indicates TX is Narrow band The 3rd character indicate Wide band or Narrow band operation.
th
The 4 “D” = Duplex mode; “R” = Repeat Mode
character on line 1 is as follows: “S” = Simplex Mode; “H” = Semi duplex Mode;
RXWS 160.0125 MHz TXN 161.8500 MHz
C001 Channel GP 500
Figure 21
Base Tech III Operating Manual
11
18) LCD back light hold By Default, back light illuminates for 5 seconds after any key press then goes out. Press SHIFT +1 for back light hold. Press SHIFT+ 1 again to be back normal. Figure-below shows back light turns on.
RX TX
C001 Channel GP Light turn ON
19) Changing TX power Press SHIFT+2 to select High and Low TX power. shows high power. If the radios are pre­programmed Hi-Lo power with programming soft, SHIFT+2 overcomes this pre-program level. Figure-below shows Hi power with SHIFT+2.
RX TX
C001 Channel GP 500
20) Caller ID BASE TECH III indicates caller's Unit ID or Individual ID. However if the radio is programmed as repeater mode, these caller's ID are not displayed. Figure-below shows caller's ID 12345.
RX TX
C001 Channel Call 0 0 1 2 3 4 5
Base Tech III Operating Manual
12
21) Emergency call reception In the 4th line of the LCD shows EMG when emergency received. LCD back light is flashing and audible tone out from speaker. Figure-below shows Emergency caller's ID
98765.
RX TX
C001 Channel EMG 98765
22) Repeater mode BASE TECH III repeats automatically when programmed as a repeater. a) Rx mode = digital
Repeats only the same NAC code. If the NAC is $F7F, all incoming signals are repeated. . Repeating shuts automatically after 0.0-9.9 seconds if no incoming signal is detected (Hang Timer
-programmable).
b) Rx mode = Mix
In addition with above conditions, radio repeats the correct CTCSS, DCS are detected, or only the carrier as well. Radio can not repeat analog and digital at the same time.
23) Remote control BASE TECH III can be controlled by remotely. Pull the EXT/CH at low level, radio works as remote mode. To recover normal mode, EXT/CH set at HI. Please note the maximum channels through remote control is up to 16 channels.
CHO – CH3 : all low .. . CH-1
CHO – CH3 : all high.......CH-16
Figure-below shows CH –1 in remote control mode. The 3rd line shows E001 instead of C001 (EXXX means remote, CXXX is Local Mode)
RX TX
E001 Channel GP 500
Base Tech III Operating Manual
13
24) P-25 Test mode Press SHIFT+ 0 to move test mode. The table for test mode are;
1/ Standard transmitter test pattern 2/ Standard transmitter symbol rate pattern 3/ Standard transmitter low deviation pattern 4/ Standard transmitter C4FM modulation fidelity pattern 5/ Standard tone test pattern Press the PTT to transmit above patterns. To change patterns, press key 1-5. Figure-23 shows test mode, LCD indicates from 1 to 5 alternatively. Figure-24 show Symbol rate Figure-25 shows Low deviati on(CTCSS/DCS) Figure-26 shows C4FM Figure-27 shows Tone test At Tone test, indicates Rx error bit rate in % Figure-28 shows error rate 45%
Figure-29 shows back to 1 mode.
<P 25 Test Mode>
Test Pattern
C0001 Channel
Figure 23
<P 25 Test Mode>
Symbolic Rate
C0001 Channel
Figure 24
<P 25 Test Mode>
Low Deviation
C0001 Channel
Figure 25
Base Tech III Operating Manual
14
<P 25 Test Mode> C4FM modulation
C0001 Channel
Figure 26
<P 25 Test Mode>
Tone Test
C0001 Channel
Figure 27
<P 25 Test Mode>
Tone Test
C0001 Channel
Error Rate 45%
Figure 28
<P 25 Test Mode>
Test Pattern
C0001 Channel
Figure 29
Base Tech III Operating Manual
15
25) Adjust mode
Ground the TP-2 on the analog logic board, and switch on the radio. Then the following parameters are adjustable. TXW or TXN will be displayed on line 2 (for Wide or Narrow TX) 1/ RX 0 dbm Out.. Rx 0dBm output level 2/ RX FX828 MOD-1... Deviation level at the repeater mode (analog) (Currently not active) 3/ TX DIGITAL DEVI… Deviation level (digital) 4/ TX ANALOG DEVI… Deviation level (analog) Press A and B to adjust the level, and # key for changing mode. Cycle power to radio to return to the normal mode. Figure-30 shows adjust mode RX 0dbm Out Figure-31 shows RX MOD-1 (Currently not active) Figure-32 shows TX MOD-Digital Figure-33 shows TX MOD-Analog
<Adjust Mode> TXW RX 0dbm Out C0001 2 5 / 3 1
Figure 30
<Adjust Mode> TXW FX828 MOD1 C0001 0 / 3 1
Figure 31
<Adjust Mode> TXW DIGITAL DEVI C0001 15 / 3 1
Figure 32
<Adjust Mode> TXW AN ALOG DEVI C0001 1 5 / 3 1
Figure 33
Base Tech III Operating Manual
16
26) Key test Keep depressing C and switch on the radio, then radio comes to Key test mode. Figure-34 shows key test mode
<Key Test>
Please Key - in
Figure 34
Then depress any key to test. Figure-35 shows CH key depressed. Figure-36 shows rotary switch turn cloc kwise Figure-37 shows rotary switch turn counter-clockwise
<Key Test>
CH Key
Figure 35
<Key Test>
RTSW UP
Figure 36
<Key Test>
RTSW DWN
Figure 37
Base Tech III Operating Manual
17
27) Displaying firmware version Both firmware and DSP soft version are indicated on LCD after the radio switch on for 2 seconds. Figure-38 shows when “no start message” is programmed
   <71BS V100 710 
 <DSP V041
>


Figure 38
Figure-39 shows start message “Your Messag Here” is programmed
Your Messag Here
Figure 39
28) Displaying serial number Press D and switch on the radio, the serial number is indicated. (max 8 digits). Releasing D key, the radio starts normally. Figure-40 shows KY0000329 serial number
r
Serial KY000329
Figure 40
Base Tech III Operating Manual
18
29) Displaying Program software version Keep pressing A and turn on the radio, then programming soft version is indicated. Releasing A key to start radio normally. Figure-41 shows V-1.00 ver s io n
Set by p-kgprg 1.00
Figure 41
30) Data check BASE TECH III has self diagnostic function. All data in EEROM is checked every time the radio is switched on. If the data is not properly stored, radio automatically turns to programming mode Figure-42 shows EROM error
EROM Data Error
Figure 42
Base Tech III Operating Manual
19
31) Error Displays Either RX PLL, TX PLL or PA power is defective, then ALM LED flashes on and indicates which unit becomes faulty. Figure-43 shows RX PLL error, Note this may be displayed in REM mode if the remote channel lines are open or a channel is selected remotely that is not programmed. (EXXX will be displayed instead of CXXX, where XXX is the channel number.) Figure-44 shows TX PLL error Figure-45 shows PA error
RX TX
C001 Channel RX PLL Error
Figure 43
RX TX
C001 Channel TX PLL Error
Figure 44
RX TX
C001 Channel PA Error
Figure 45
32) Firmware error detection
When the radio itself detects malfunction, the main CPU will restart automatically.
33) RS232 error detection If the communications between PC and the radio have trouble, the following message are shown on the LCD. 1/ Over run error 2/ Framing error 3/ Parity error 4/ Unknown command 5/ Data unmatched 6/ Send error 7/ Answer timeout 8/ Receive timeout
Base Tech III Operating Manual
20
34) DSP error detection When DSP does not work properly, the following message are shown
on the LCD. Please check DSP board is firmly connected, or replacing the DSP board. Figure-46 shows DSP failure Figure-47 shows DSP not ready Figure-48 shows DSP serial error
RX TX
C001 Channel DSP Failure!
Figure 46
RX TX
C001 Channel DSP not ready
Figure 47
RX TX
C001 Channel DSP serial Err!
Figure 48
Base Tech III Operating Manual
21
5900 PARRETTA DRIVE KANSAS CITY MISSOURI 64120
PHONE: (816) 241-8500 FAX: (816) 241-5713
www.midlandradio.com
Loading...