Thank you very much for the trust you have demonstrated by purchasing this unit.
More than 55 years ago, MELAG began as a medium-sized family-run enterprise to specialise in the
manufacture of sterilization equipment for medical practices. In the meantime our company has grown
into one of the world's leading producers of sterilization equipment. Verification of it success has been
the sale of more than 400,000 MELAG units worldwide, attesting to the high quality of our sterilizers,
which are exclusively made in Germany.
Please read this Operating Manual before you start operation of the CF Card Printer.
The instructions contain important information and safety precautions.
MELAG - General Management and employees
Page 2
Safety instructions
To operate the CF Card Reader, pay attention to the safety instructions
given below and in the individual chapters of this Operating Manual.
■Do not open the housing of the CF Card Printer. Improper opening
and repair could impair the electrical safety and pose danger to the
user.
■Only connect devices to the CF Card Printer which were intended for
use with this printer.
■Only operate the CF Card Printer with the plug-in power supply unit
included in the scope of delivery.
■No fluids may get into the interior of the CF Card Printer. Electrical
shocks or a short circuit could result.
■Do not place the CF Card Printer directly on the autoclave. The
autoclave becomes hot during operation. Non-compliance could
impair the function and lead to damage of the plastic housing of the
CF Card Printer.
To these instructions
Symbol
Example of font type
Batch output
Chapter 6 – Logging
Figure 1/(5)
Important
Software citation Words or phrases appearing on the ?display of the
Cross-reference Reference to another text section within this Operating
Cross-reference Reference to a detail in a figure – in the example, to
Meaning Explanation
Be sure to
observe
information
Meaning Explanation
Indicates situations which might lead to damage of the
MELAnet Box if not complied.
Indicates important information.
autoclave are marked as software citations.
Manual.
Part No. 5 in Figure 1.
Symbols on the unit
The symbol of the struck out trashcan identifies a device that may not be
disposed with domestic waste. An appropriate and competent disposal
must be carried out by the marketing party.
With the designation of an apparatus with this symbol, the manufacturer
furthermore declares that he satisfies all requirements of the law
concerning the release, withdrawal and environmentally compatible
disposal of electric and electronic appliances.
Page 3
CONTENTS
Scope of delivery................................................................................................................................................... 3
LED Status Displays................................................................................................................................................ 5
Filing structure and filenames.................................................................................................................................. 9
Open logs with MELAview..................................................................................................................................... 10
Open and save logs with standard programs on the PC ....................................................................................... 10
For the power supply, connect the cable of the delivered plug-in
power supply unit to the right-hand socket (see 4, Fig. 1/(1) , of the CF
Card Printer.
Plug the power plug into the socket.
The power LED lights up green.
Connect the RS232 interface of the serial cable to the serial data
connection of the autoclave.
We recommend you to tightly screw both the knurled screws on the
serial connection to avoid them from getting loose or inadvertently
being pulled out.
Notice!
For more detailed information about connecting the serial cable, consult
the Operating Manual.
Insert the MELAflash CF card
Insert the delivered MELAflash CF card into the slot on the front of the
MELAflash CF Card Printer.
Make sure the card is facing the right direction and do not use force to
insert it into the slot.
If you do not observe this precaution, the CF card or the CF Card Printer
can be damaged.
red data LED is not lit up.
If you pull the CF card out of the CF Card Printer while the red data LED
is still lit up, data saved on the card can be lost.
Warning!
Warning!
Only remove the MELAflash CF card from the CF Card Printer when the
Format MELAflash CF card
Insert the CF card into the slot as far as you can before it makes
At delivery the CF card is already formatted, i.e. you can use it
immediately.
If it should nevertheless ever be necessary to format the CF card, always
do so with the CF Card Printer. It formats the CF card in the format the
device requires (FAT16).
contact with the limit stop, but is faced in the right direction in the slot.
Keep the "format" button pressed down (about 7 sec) until the red
data LED begins to blink repeatedly.
This signifies that the CF Card Printer is in formatting mode for a short
time (about 5 sec).
While the red data LED is blinking, insert the MELAflash CF card
completely into the slot of the MELAflash CF Card Printer until the
limit stop.
The CF card will now be formatted. The red data LED lights up
steadily during the formatting process.
When the formatting is completed, the red data LED goes out.
All saved data on the CF card is deleted during formatting.
Warning!
Initialise the MELAflash CF Card Printer on
the autoclave
In order to be able to save sterilization logs on the MELAflash CF Card via
the CF Card Printer, you have to set the MELAflash CF Card Printer as
output medium on the autoclave.
The settings you make depend on which device software is installed on
your autoclave.
Settings for the
autoclave software version
up to V3.3
Set immediate printout of th
The MELAflash CF Card Printer is now ready for operation and
Settings for th
autoclave software version
as of V4.0
Switch on the power at the autoclave and wait until the display shows
the initial state.
Select the setup menu Function by simultaneously briefly pressing
the (+) and (–) K
EYS.
The display shows Function: Print .
Press the (P) K
Again press the (P)
EY to select the submenu Print – Data transfer.
KEY. The display shows Data transfer – no
printer, if a printer has not yet been set.
Navigate with the (+)
KEY until the display shows Data transfer –
external PC.
Press the (P) KEY to confirm the selection. The display returns to the
men Print – Data transfer.
Press the (S) K
EY twice to exit the menu and return to the initial state.
In order to save the sterilization logs on the CF card directly after the end
of a sterilization program, you must activate the option on the autoclave for
immediate printout.
Select the Setup Menu Function by short simultaneous pressing of
logs
the (+) and (-)
KEY. The display shows Function: Print.
Press the (P) KEY. The menu Print – Data transfer is displayed.
Navigate with the (+) or (-)
KEY until the submenu displays Immediate
printout Yes/ No.
If the option is set to NO, press the (P)
Print NO to YES.
KEY to switch from Immediate
In order to exit the menu, likewise press the (S) KEY.
sterilization logs can be saved on the CF card.
Switch the autoclave on with the power switch.
Select the Setup Menu Function by short simultaneous pressing of
read access procedure. The red LED lights up during the write and
read access procedure.
Filing structure and filenames
Folder structure
Filename structure
The day of the year can take values from 1 to 366. The day batch can
The storage of files on the CF card as well as the created folder structure
is organised as follows:
The folder name of the uppermost level consists of 5 characters and
contains encoded in the name: the year of manufacture, the type of unit
and the autoclave's Manufacturing Number. On the level below, the
folders are named by month and year.
If necessary, an additional folder ERROR and/or UNKNOWN is created.
Here the faulty logs (ERROR) or non-recognised logs (UNKNOWN) are
stored separately.
The first five characters of the file names of the saved logs correspond to
the folder name of the uppermost level.
The characters 6 - 8 of the filename consist of the day and the day batch
of the corresponding log:
take values from 1 to 127.
Thus every log receives a unique filename within the time period of one
calendar year. Logs of different calendar years can receive the identical
file names but are stored in separate directories.
9
Page 10
Chapter 4 – Logging
Meaning of the file
extensions of the
sterilization logs
STB Standby malfunction log DEM Demo log
LOG System log DES Demo malfunction
MELAview 2.0
for displaying, editing and
printing log files
MELAview 2.0
Demo version
Save preferred path
PRO Logfile (successful) STA Status log
STR Malfunction log LEG legend log
RECOMMENDATION
To avoid inadvertent data loss, we recommend the regular backup of the
sterilization logs on the CF card onto the medical practice PC (e.g.
weekly).
Open logs with MELAview
The program MELAview 2.0 is for simple viewing, editing, and printing of
MELAG sterilization logs. This program is a kind of log browser.
You can also display log lists with MELAview. You can sort the
sterilization logs in ascending or descending order, filter over selection
fields and print the logs direct from MELAview. You can purchase
MELAview 2.0 from your MELAG dealer.
Before you decide to purchase MELAview 2.0, MELAG offers you the
opportunity of testing the program without charge.
On the delivered CF Card there is a demo version of MELAview so that
you can look at the functions of MELAview using fictive sterilization logs
as examples. Please notice that the program will be deleted in case of
formatting the CF card.
Your MELAG dealer can also provide you with a demo version on CD
ROM.
In order to rapidly open preferred folders for sterilization logs, it is possible
to save the respective path as a favourite.
10
Open and save logs with standard programs
on the PC
The sterilization logs are in ASCII format and can be read with simple text
editors or other standard programs of any operating system. The
extensions of the logfiles which you copy to the PC with the Card Reader
make it initially impossible for a PC to open such files the first time you
attempt to do so.
You must first once allocate every possible file extension e.g. to the Text
Editor of Windows as program. Subsequently you can open the
sterilization logs simply by double-clicking on the file with the left mouse
button.
In order to open the log Text Editor of Windows, proceed as follows:
Page 11
Chapter 4 – Logging
A
Open the directory on your PC where
the logfiles are stored.
Double-click on the logfile.
If the respective file extension is
unknown, the dialog window depicted on
the left opens up:
Choose "Select program from a list"
and confirm with OK (A).
.
A separate dialogue window opens up.
Look for the Editor (B) in the listed
programs and select it.
Make sure that the checkmark is set to
"Always open this file type with the
selected program" (C). That is important
so that the Editor can recognise future
logfiles with the same file extension.
Confirm with OK. From now on you can
always open the logfiles simply by
double-clicking.
B.
C.
11
Page 12
Chapter 5 – Error conditions
Chapter 5 – Error conditions
Before saving the data, the MELAflash CF Card Printer verifies the log
Unknown log file
Faulty log file
CF card incorrectly
formatted
CF card defect
data transferred from the autoclave.
If a log file is not recognised, the system creates a directory UNKNOWN
on the CF card.
Moreover, the red data LED and the green power LED steadily blink
alternately (see Table, row 06 on p. 5, LED Status Displays).
To reset the error condition, press briefly on the "Format" button on the top
of the MELAflash CF Card Printer (see p. 4, Fig. 1/(3)).
If there is an error in the data transmission from the autoclave to the CF
Card Printer, i.e. while a logfile is being saved on the CF card, the system
creates the directory ERROR.
Here the red data LED and the green power LED also steadily blink
alternately (see Table, row 06 on p. 5, LED Status Displays).
To reset the error condition, press briefly on the "Format" button on the top
of the MELAflash CF Card Printer (see 4, Fig. 1/(3)).
If the CF card is incorrectly formatted, this is indicated by a steady red
blinking of the red data LED (see Table, row 07 on p. 5, LED Status
Displays).
Reformat the CF card in the CF Card Printer (see 6, Format
MELAflash CF card).
If the CF Card Printer detects a defect in the inserted CF card, this is
indicated by a steady red blinking of the red data LED (see T ab le, row 07
on p. 5, LED Status Displays).
In this case replace the defect CF card with a new one.
Appendix – Accessories
Article Order No.
plug-in power supply for MELAflash CF Card Printer 30403
MELAflash Card Reader 01048
MELAflash CF Card 01043