MCZ FC700-715 User Manual

INSTALLATION AND USE MANUAL
Contents
page
1
INTRODUCTION....................................................................................................................................2
1.1. SAFETY WARNINGS........................................................................................................................3
1.2. OPERATING WARNINGS..................................................................................................................3
1.3. WARRANTY CONDITIONS................................................................................................................3
1.3.1. Restrictions..............................................................................................................................3
1.3.2. Exclusions................................................................................................................................4
2.1. Components of kit VF 480-620 m3/h with control unit FC715 (Airsystem line)....................................... 5
2.2. Components KIT VF 180 m3/h with control unit FC715 (only Airsystem B70)........................................6
2.3. FORCED VENTILATION KIT 480-620 m3/h ........................................................................................7
2.4. FORCED VENTILATION KIT 180 m3/h (ONLY B70).............................................................................7
2.5. CONNECTION OF CONTROL UNITS AND PROBES..............................................................................8
2.5.1. Control unit FC715 and probe installation ...................................................................................8
2.5.2. Positioning of control unit and FC715.........................................................................................8
2.5.3. Ducts for kit VF 480-620 m3/h...................................................................................................9
2.5.4. Ducts for kit VF 180 m3/h (Airsystem B70)................................................................................10
2.6. COMPONENTS OF KIT VF 480 m3/h WITH CONTROL UNIT FC715.....................................................11
2.6.1. Installation of fan 480m3/h......................................................................................................12
2.6.2. Installation of temperature probe ............................................................................................12
2.6.3. Positioning of control unit FC715 .............................................................................................13
3.1. RADIO REMOTE CONTROL ............................................................................................................14
3.1.1. Turning on and off .................................................................................................................14
3.2. MANUAL MODE.............................................................................................................................14
3.3. AUTOMATIC MODE.......................................................................................................................15
3.4. OTHER FUNCTIONS OF THE CONTROL UNIT FC 715.......................................................................15
3.4.1. Setting transmission code of the radio remote control ...............................................................15
4.1. MAINTENANCE OF KIT VF .............................................................................................................17
4.1.1. Electric fan ............................................................................................................................17
4.1.2. Control unit FC 715 ................................................................................................................17
4.1.3. Radio remote control..............................................................................................................17
4.1.4. Probe....................................................................................................................................17
4.1.5. Wiring...................................................................................................................................17
4.2. CLEANING TO BE DEALT WITH BY SPECIALIZED TECHNICIAN.........................................................17
4.2.1. Cleaning flue pipe...................................................................................................................17
Contents Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
INSTALLATION AND USE MANUAL
INTRODUCTION
Dear customer, Thank you for choosing an MCZ product, specifically a
fireplace stove of the Airsystem line. We are sure that, with use, you will appreciate the
quality of an attentively designed and tested product. Our goal is to combine technology with easy use and, above all, safety.
For best fireplace stove operations and to fully enjoy the heat and sense of well being it will spread throughout your home, we suggest you carefully read this booklet before use. Please contact your dealer for full assistance in resolving any doubts or problems.
Congratulations on your choice and remember, the fireplace stove MUST NEVER be used by children who should always be kept at a safe distance from your stove!
Revisions to the publication
In order to improve the product, the Manufacturer reserves the right to modify and update this publication without prior notice.
Reproduction, even partial, of this manual without the Manufacturer's authorisation is prohibited.
Manual preservation
Please take care of this manual and keep it in a place that can be quickly and easily reached.
If this manual should be lost or destroyed, or if it is in poor condition, ask for a copy from your retailer or directly from the manufacturer, providing product identification data.
How to read the manual
An essential item or one that requires specific attention is published in “bold”.
“Italics"
NOTE: the “NOTE” provides the reader with
additional information on the subject.
These symbols signal specific messages in this booklet
are used for any additional clarification.
Chapter 1
page
2
WARNING: This warning symbol found in various
points in this manual indicates that the user should carefully read and understand the message to which it refers since
neglect to follow these instructions could cause serious fireplace stove damage or injury to the user.
INFORMATION:
This symbol intends to emphasise important information for good fireplace stove operations. Failure to observe these instructions could jeopardise product use and operations may be unsatisfactory
Introduction Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
INSTALLATION AND USE MANUAL
1. WARNINGS AND WARRANTY
CONDITIONS
these cases.
1.2. OPERATING WARNINGS
Chapter 1
page
3
1.1. SAFETY WARNINGS
Installation of the stove, electrical
connections, checking its operation, and maintenance are all tasks which should be carried out by qualified and authorised personnel.
Install the fireplace stove according to
correct local, regional or state regulations.
For correct use of the fireplace stove and
accessories, and to prevent accidents, always follow the instructions in this booklet.
Before beginning any operation, anyone who
uses the stove must read and understand the entire contents of this instruction booklet.
The fireplace stove must be used only for its
intended purpose. Any other use is considered improper and therefore hazardous.
Check the conditions of the surface that will
support the weight of the stove. If it is made of flammable material such as wood, carpet, or plastic, provide suitable insulation.
Avoid installation in rooms with B type gas
devices, hoods with or without exhaust, heat pumps, collective ventilation conduits.
Do not install several flue pipes in one room, and
avoid having a stairwell in the vicinity. Check that in adjacent connected room there are not any units whose simultaneous use would create negative pressure in one of the two rooms.
The user is fully liable for improper product use,
releasing MCZ from any civil or penal liabilities.
Any tampering with the fireplace stove, or use of
non-original spare parts, may be hazardous to the user and releases MCZ from any civil or penal liability.
Parts of the surfaces of the fireplace stove are
very hot (door, handle, glass). Therefore, avoid direct contact with these parts unless wearing protective clothing or specific means such as, for example, heat protective gloves or "cold" activation devices.
Carefully explain this hazard to elderly people,
disabled people and particularly to all children, keeping them away from the fireplace stove while it is in operation.
Incorrect installation or poor maintenance (not
compliant with the provisions of this manual) may cause damages to persons, animals or property. MCZ is not civilly or criminally liable in
Turn off the fireplaces stove in the event of faults or poor operations.
Install the fireplace stove in a location which is suitable for fire fighting, and equipped with all services such as air, water and electricity supply and smoke discharge.
Do not light the fire with flammable materials.
INFORMATION:
For any problem, please contact your dealer or MCZ qualified and authorised personnel and always request original spare parts for repairs.
Only use the fuel stated by MCZ.
Check and periodically clean the smoke exhaust
stack as foreseen by current regulations in the country of installation.
Carefully conserve the instruction booklet. It must remain with the fireplace stove for its entire life cycle. If the stove is sold or transferred to another user, make sure the manual accompanies the product.
If lost, please request a copy from your dealer or from MCZ.
1.3. WARRANTY CONDITIONS
MCZ guarantees the product, except for the elements subject to normal wear listed below, for
two years from the date of purchase proven by a document that indicates the dealer's name and date of sale, if the completed warranty certificate was returned within 8 days and if the product was installed and inspected by a specialised installation technician and according to the detailed instructions indicated in the instruction manual supplied with the product.
The warranty includes the free replacement or repair of parts recognised as factory defective.
1.3.1. Restrictions
The above guarantee does not cover components relating to electrical parts, on which the guarantee period is 1 year from the purchase of the product, documented as specified above. The warranty does not cover parts subject to normal wear such as:
gaskets, glass, and all removable fire box parts.
Replaced parts will be guaranteed for the remaining warranty period from the date of product purchase.
Warnings and warranty conditions Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
INSTALLATION AND USE MANUAL
Specifically, glass is guaranteed from the moment the MCZ installation technician certifies its integrity when installation is completed.
1.3.2. Exclusions
The warranty does not cover any part that may be defective due to negligence or careless use, incorrect maintenance, installation non compliant with that specified by MCZ (see relevant chapters in this manual).
MCZ refuses to accept any responsibility for any damage which may be caused, directly or indirectly, by persons, animals or things as a result of the failure to observe all the provisions set forth in the instruction booklet, especially those concerning warnings on the subject of installation, use and maintenance of the appliance.
In the event of product inefficiency, please contact your dealer and/or area importer.
Damages caused by transport and handling are not covered by the warranty.
Exclusively refer to the supplied manual for product installation and use.
The warranty is null and void in the event of damage due to tampering, weather, natural calamities, lightening, fire, defective electrical and hydraulic systems and the lack or incorrect maintenance as per the manufacturer's instructions.
SERVICE REQUESTS Service requests must be addressed
to the dealer who shall forward the request to MCZ technical assistance.
MCZ is not liable in the event the product and any other accessory is improperly used or modified without authorisation.
Only original MCZ spare parts must be used for all replacements.
Chapter 1
page
4
Warnings and warranty conditions Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
5
INSTALLATION AND USE MANUAL
Chapter 2
page
5
2. INSTALLATION OF FORCED VENTILATION KIT
2.1. Components of kit VF 480-620 m3/h with control unit FC715 (Airsystem line)
4
ACOUSTIC SIGNAL EMITTER
FUSE
LINE SIGNAL LED
6
3
Yellow-green
Brown
Blue
1
2
Diagram 1 – Wiring Kit VF for Airsystem (not including Airsystem B70) with control unit FC 715
1. Radio remote control complete with internal battery
2. Fan cable with plug and terminals
3. Supply cable with plug and socket
4. Power supply device with built-in radio receiver
5. Fan 480-620 m³/h
6. Silicon probe cable with snap-in connection complete with electronic probe (for control unit mod. FC715)
Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
INSTALLATION AND USE MANUAL
Chapter 2
page
6
2.2. Components KIT VF 180 m3/h with control unit FC715 (only Airsystem B70)
4
ACOUSTIC SIGNAL EMITTER
FUSE
LINE SIGNAL LED
6
3
7
1
2
Diagram 2 – Wiring Kit VF for Airsystem for B70 with control unit FC 715
1. Radio remote control complete with internal battery
2. Fan cable with plug and terminals
3. Supply cable with plug and socket
4. Power supply device with built-in radio receiver
3
5. Two fans of 180 m
/h
6. Silicon probe cable with snap-in connection
complete with electronic probe (for control unit mod. FC715)
7. Bracket with terminal block for connection of fans
Yellow-Green
Yellow-Green
n
e e
r G
­w
o
l
l
e
Y
n w o
r B
n w o
r B
5
e u
l B
e
u
l B
Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
INSTALLATION AND USE MANUAL
IMPORTANT! PRIOR TO INSTALLATION, ENSURE THAT THE
KNOCKOUT PANELS LOCATED ON THE BOTTOM OF THE FIREPLACE STOVE HAVE NOT
BEEN REMOVED.
IF THE KNOCKOUT PANELS HAVE BEEN REMOVED (SEE PAGE 25), YOU WILL NEED TO PUT THEM BACK OR CLOSE OFF THE HOLES WITH STEEL PLATES.
2.3. FORCED VENTILATION KIT 480-620 m3/h
For the installation of the forced ventilation kit of 480-620 m3/h, proceed as follows:
Raise the door of the fire box
Remove the cast iron grille, the ash drawer and the two semi-
tops in white refractory material (Alutec®)
Unscrew the self-tapping screws B and remove the hermetic bottom C
(figure 10)
Insert the electric fan kit 480 or 620 m fastening flange facing as shown in inserts of the flange fit into the slots Z of the back foot.
Raise the fan block as in the flange with those of the bottom of the fireplace stove.
Lock all in place by tightening the two screws A, from above the back, so as to secure the fan 480-620 m
(figure 10)
.
Before putting the hermetic bottom C back in place, make the electrical connections as shown in the following paragraph.
Once the electrical connections are complete, put the hermetic bottom C back in place and secure it with the self-tapping screws B
(figure 10)
Make sure that the removable bottom C is hermetically sealed and that the gaskets mounted on the bottom are in good shape.
figure 11
3
/h complete with
figure 11
, so that the two
so as to match the holes of
3
/h to the frame
Chapter 2
page
7
A
B
Figure 10 – Disassembly of internal fire bed
Figure 11 – Fan position 480-620 m3/h
A
B
C
C
2.4. FORCED VENTILATION KIT 180 m3/h (ONLY B70)
For the installation of the forced ventilation kit of 180 m3/h, proceed as follows:
Raise the door of the fire box
Remove the cast iron grille, the ash drawer and the two semi-
tops in white refractory material (Alutec®)
Unscrew the self-tapping screws B and remove the hermetic bottom C
(figure 12)
Insert the fans of 180 m
3
/h, facing as in
figure 13,
so that the insert on the flange of the fan enters the slot on the structure of the fireplace stove
(figure 13)
.
Secure the fans to the frame by tightening the two screws A from above the back
(figure 12)
Fasten the steel bracket with the terminal board for electrical wiring with the self-tapping screw F provided
Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
(figure 14).
Figure 12 – Disassembly of internal fire bed
Asola
Figure 13 – Fan installation
Before putting the hermetic bottom C back in place, make the electrical connections as shown in the following paragraph.
Once the electrical connections are complete, put the hermetic bottom C back in place and secure it with the self-tapping screws
(figure 14)
B
Re-insert the fire beds, the drawer and the ash grille
Make sure that the removable bottom C is hermetically sealed and that the gaskets mounted on the bottom are in good shape.
INSTALLATION AND USE MANUAL
Chapter 2
page
8
F
2.5. CONNECTION OF CONTROL UNITS AND PROBES
All wiring must be carried out with the electrical sockets disconnected. Make sure that the electrical sockets are grounded.
2.5.1. Control unit FC715 and probe installation
Arrange in advance for the connections of the control unit FC715 as shown in
3
/h or as in
m 180m
PROBE INSTALLATION:
Screw in without tightening completely the screw that holds
Screw in the entire probe support E+F+G in the hole D (size 10
Insert probe H all the way into the hole of the screw that holds
The probe will be inserted in the upright of the fireplace stove C.
Once the connection is complete and the plug placed in the socket of the home, check that the red LED on the control unit lights up.
diagram 1
3
/h.
the probe G to the probe support E, placing in between the bush F
wrench)
probe G and gently tighten the screw G (size 7 wrench).
diagram 2
(figure 16).
All wiring must be carried out with the electrical sockets disconnected. Make sure that the electrical sockets are grounded.
of page 29 if you are installing a kit of 480-620
on page 30 if you are installing a kit of
Figure 14 – Installation of bracket with terminal board
Griglia cener e
Sezione del piano fuoco
Cassetto
cenere
Piedino posteriore
C
D E F
G H
C
D E F
2.5.2. Positioning of control unit and FC715
The control unit must be placed on the floor, behind or alongside the fireplace stove, in a zone that is accessible for maintenance and above all far from the bottom of the structure as shown in Make sure that the control unit does not come into hot metallic parts of the fireplace stove, as it can be damaged by heat.
The equipment must be powered at 220V at 50Hz. Correct connection to the earth system is vital. Make sure that the cables do not come into contact with the
metal parts of the structure, as they get extremely hot.
Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
figure 17.
Figure 16 – Probe installation
G H
A
INSTALLATION AND USE MANUAL
Chapter 2
page
9
LL MODELS AI RSYSTEM AD
ONLY MODEL Airsystem B70
EXCEPT FOR AIRSYSTEM B7 0
A = Control un it FC715 B = Fan 480/620 m /h
3
A
A = Control unit FC715 B = Fan 480/620 m /h
A
A
A
Position of control unit (A) seen from above
Figure 17 – Position of the control unit
Position of control unit (A) seen from above
2.5.3. Ducts for kit VF 480-620 m3/h
If the fireplace stove is installed with forced ventilation, i.e. using a fan of 480 or 620 m
for proper air circulation in the room, it is advisable to connect one of the two ducts to the exterior of the home, creating an air intake of 150 cm² the room where the fireplace stove is installed (also of 150 cm²
This mode allows a proper mix of the air in the room of installation and better cooling of the structure of the fireplace stove.
If you cannot make this kind of connection, you will still need to connect both ducts, whether they are both directed to the exterior or the interior. Depending on the selection, you will have operating temperatures that are slightly above or below average but which do not compromise proper operation of the product.
3
/h, place air intakes and ducts as follows:
, in order to draw in clean, fresh air; place the other in
).
(Figure 8)
ALWAYS
CONNECT THE TWO DUCTS AND RUN THEM
OUTSIDE THE CLADDING OF THE FIREPLACE STOVE. IF THIS DIRECTIVE IS NOT OBSERVED, THE FAN,
HAVING GREATER STATIC PRESSURE, MAY ALSO INTAKE AIR INTENDED FOR THE FRONT GRILLE OF THE FIREPLACE STOVE AND REQUIRED FOR COMBUSTION
A
3
A
Combustion air intake of
2
150 cm
Internal and external air intakes of 150 cm2 for forced ventilation air.
Figure 8 – Air intakes for ducts of fan and combustion air intake.
Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
g
INSTALLATION AND USE MANUAL
2.5.4. Ducts for kit VF 180 m3/h (Airsystem B70)
Differently from the kit VF 480-620 m3/h, the kit VF 180 m3/h does not require ducts, since the lower power of the fans and their position
with respect to the fireplace stove allow proper operation of the system provided a considerable quantity of air is provided under the unit.
Considering that this type of fireplace is normally set in an internal wall of the home and it is almost never possible to provide ducts to the outside of the home as with the previously described model, the ventilation air must all be drawn from the room of installation, using the air intakes on each side of the cladding
It is necessary to provide two air intakes with a net minimum section
of 150 cm
exchange of oxygen under the fireplace stove
2
on both sides of the cladding that allow a continuous
(figure 9).
If the air intakes are not sufficient, the fans will also draw the air required for combustion, and this will compromise proper operation of the product.
DIAGRAM OF AIR INTAKES ONLY FOR MODEL AIRSYSTEM B70
Chapter 2
page
10
Fire bed Fire bed
Ventilation
and combustion
air intake grille
It is advisable to use two grilles of at least 20x10 cm
Remember that:
All of the air intakes must be equipped with shutters than can be controlled from the outside and that are equipped with insect protection.
The air intake section is considered net, therefore the area of any obstructions must be considered (mesh, etc.)
The filters or meshes need to be cleaned periodically to ensure air can pass through them.
Do not for any reason obstruct the air intakes if the fireplace stove or ventilation kit is in operation
Figure 9 - Air intake grilles for ventilation and combustion air
Ventilation
and combustion
air intake
rille
Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
INSTALLATION AND USE MANUAL
2.6. COMPONENTS OF KIT VF 480 m3/h WITH CONTROL UNIT FC715
Diagram 1 – Wiring Kit VF for Forma with control unit FC 715
4
ACOUSTIC SIGNAL EMITTER
FUSE
LINE SIGNAL LED
6
3
Yellow-green
Brown
Chapter 2
page
11
1
2
7. Radio remote control complete with internal battery
8. Fan cable with plug and terminals
9. Supply cable with plug and socket
10. Power supply device with built-in radio receiver
IMPORTANT! PRIOR TO INSTALLATION, ENSURE THAT THE
KNOCKOUT PANELS LOCATED ON THE SIDE OF THE FIREPLACE STOVE HAVE NOT
IF THE KNOCKOUT PANELS HAVE BEEN REMOVED (SEE PAGE 19), YOU WILL NEED TO PUT THEM BACK OR CLOSE OFF THE HOLES WITH STEEL PLATES.
BEEN REMOVED.
Blue
5
11. Fan of 480mc/h
12. Silicon probe cable with snap-in connection complete with electronic probe
Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
A
INSTALLATION AND USE MANUAL
Chapter 2
page
12
2.6.1. Installation of fan 480m3/h
For the installation of the forced ventilation kit of 480 m3/h, proceed as follows:
1. EXTRACT THE HERMETIC BOTTOM:
Raise the door of the fire box
Remove the refractory panels (Alutec®)
Loosen the self-tapping screws A and remove the tray B that
contains the alutec panels
(figure 10)
Extract the hermetic bottom C by loosening the two nuts D
(figure 10)
2. INSTALL THE FAN ON THE HERMETIC BOTTOM
On the hermetic bottom, locate the fastening holes located around the flange of the fan
3
Screw in the electric fan of 480m
/h using the previously
identified holes on the hermetic bottom using the screws E
(figure 11)
Before putting the hermetic bottom B back in place, make the electrical connections as shown in the previous paragraph.
Use special care when installing the temperature probe.
3. INSTALLATION OF TEMPERATURE PROBE
Follow the instructions in the next paragraph
2.6.2. Installation of temperature probe
FORMA
section
Alutec
panels
Tray
B
Bottom
C
D
Figure 10 – Disassembly of internal hermetic
bottom
Bottom
C
Fan
E
It is advisable to provide in advance for the connections of control unit FC715 as shown in
diagram 1
on page 22.
PROBE INSTALLATION:
Identify the pass-through hole for the insertion of the probe D, located on the right or left side of the fireplace stove
(figure 12)
Insert in the hole D the screw that supports the probe E and lock it with the nut H
Screw in without tightening completely the screw that holds the probe G to the probe support E, placing in between the bush
(figure 12).
F
Insert probe S all the way into the hole of the screw that holds probe G and gently tighten the screw G (size 7 wrench).
Once the connection is complete and the plug placed in the socket of the home, check that the red LED on the control unit lights up.
All wiring must be carried out with the electrical socket disconnected.
Make sure that the electrical sockets are grounded.
Figure 11 – Installation of fan 480 m3/h
H
D
E
G
Figure 12 – Probe installation
F
S
Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
INSTALLATION AND USE MANUAL
2.6.3. Positioning of control unit FC715
The control unit must be placed on the floor, behind or alongside the fireplace stove, in a zone that is accessible for maintenance and above all far from the bottom of the structure as shown in
figure 17.
Make sure that the control unit does not come into hot metallic parts of the fireplace stove, as it can be damaged by heat.
The equipment must be powered at 220V at 50Hz. Correct connection to the earth system is vital. Make sure that the cables do not come into contact with the
metal parts of the structure, as they get extremely hot.
Chapter 2
page
13
B
A
Figure 17 – Position of control unit A and fan B.
Installation and assembly Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
INSTALLATION AND USE MANUAL
3. OPERATION OF CONTROL UNIT FC 715
The device allows the speed of the fan which is under the user's control by means of the radio remote control, to be regulated in one of two modes:
MANUAL The fan (5) runs at the selected speed independently
of the Sensor.
AUTOMATIC The fan (5) runs at the selected speed with the
permission of the sensor.
3.1. RADIO REMOTE CONTROL
The radio remote control has 4 push buttons that can be used to carry out the following operations
On/off (blue key)
Change operating mode from manual to automatic and vice
versa (red key)
Variation of the 4 speeds of the fan (yellow keys)
Chapter 5
page
14
3.1.1. Turning on and off
TURNING ON: Press and hold the blue ON/OFF button of the radio
remote control to turn the fan on at the first speed in MANUAL mode. The control unit emits a short beep that identifies 1
st
speed in manual mode.
TURNING OFF: Press and hold the blue ON/OFF button of the radio
remote control to place the device in STAND-BY mode, which is signalled by a very long beep, and shut down the fan.
3.2. MANUAL MODE
By default, when turned on using the ON/OFF button, or simply by clicking the red MAN/AUT button, the system goes into MANUAL mode. This mode can be recognized by the fact that all of the sound
signals emitted by the control unit in this status are short beeps and the fan is always on regardless of the temperature.
The yellow + and - buttons are used to increase/decrease the speed of the fan from 1 number of short beeps that corresponds to the selected speed:
Regardless of whether the fireplace stove is on or not, the fan comes on, emitting air at the set speed.
st
to 4th and vice versa. The control unit responds with a
1st speed= 1 short BEEP
nd
speed= 2 short BEEPS
2
rd
speed= 3 short BEEPS
3
th
speed= 4 short BEEPS
4
Operation Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
INSTALLATION AND USE MANUAL
3.3. AUTOMATIC MODE
Once ventilation is turned on in manual mode, by pressing the red MAN/AUT of the radio remote control, the device goes to AUTOMATIC mode. The mode can be recognized by the fact that all the sound
signals emitted by the control unit in this status are long beeps.
The yellow + and - buttons are used to increase/decrease the speed of the fan from 1 number of short beeps that corresponds to the selected speed:
Ventilation is turned on and off exclusively by the temperature of the thermostatic probe.
AUTOMATIC START BY MEANS OF THE PROBE:
If the temperature detected by the probe is greater than 45°C, the fan comes on at the set speed (1 that performs a countdown starting from 40 minutes. This period of 40 minutes is called the “
After 40 minutes, if the temperature of the probe exceeds 65°C, it means that the internal temperature is rising because the fireplace stove is coming up to operating power, and therefore the fan must stay on. After 40 minutes, if the probe does not reach 65°C, it means that the power of the fire is low and the ventilation must be shut off.
If the user changes the speed while the system is between 45°C and 65°C, this is interpreted as a request for ventilation. The system goes back to the countdown begins.
AUTOMATIC SHUTDOWN BY MEANS OF PROBE:
If the temperature probe drops below 65°C, ventilation is shut off.
st
to 4th and vice versa. The control unit responds with a
1st speed= 1 long BEEP
nd
speed= 2 long BEEPS
2
rd
speed= 3 long BEEPS
3
th
speed= 4 long BEEPS
4
warm-up phase"
warm-up phase;
st
speed) and an internal timer is activated
.
the timer is reset to 40 minutes and the
Chapter 5
page
15
3.4. OTHER FUNCTIONS OF THE CONTROL UNIT FC 715
STAND-BY: The fan is off because the blue ON/OFF button of the
radio remote control has been pressed. Shutdown is signalled by a long beep.
SAFETY: In STAND-BY status, if the temperature exceeds 150°C, the fan comes on at speed 1 and the system goes into AUTOMATIC mode. Ventilation continues until the temperature drops below 65°C.
STATUS RECOVERY: the system automatically saves, in non-volatile memory, the last power setting made by the user, allowing continuation at the speed after a power outage.
3.4.1. Setting transmission code of the radio remote control
The radio remote control and the control unit are set with a neutral code that makes it possible to check operation of the ventilation kit immediately, before the cladding is completely installed.
Operation Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
INSTALLATION AND USE MANUAL
It may however be necessary to change this code, and as a result the transmission frequency, if another fireplace stove is located nearby (e.g. if your neighbour has one) or if other signals interfere with transmission.
The code can be personalized as follows:
Unplug the control unit
Open the battery compartment of the radio remote control by
moving the cover in the direction of the arrow
(Figure 20)
Raise any one, or more than one, of the 10 white keys as shown in the example in
figure 21.
Close the radio remote control
Press and hold the red key of the radio remote control, and at
the same time plug it back in.
After a maximum of 15 seconds, a prolonged beep or a series of beeps in sequence confirm that the radio remote control has been connected to the control unit with the new code.
Chapter 5
page
16
ON
MAN
OFF
AUT
BATTERY COMPARTMENT
AND SWITCH
Figure 20 – Switch in battery compartment of radio remote control
Figure 21 – Example of variation of code
Operation Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
INSTALLATION AND USE MANUAL
4. MAINTENANCE AND CLEANING
4.1. MAINTENANCE OF KIT VF
The maintenance of all electrical parts (fan, control unit, etc.) must only be carried out with no electrical power supplied and with the unit unplugged.
4.1.1. Electric fan
Periodically, and at least at the end of each winter, it is advisable to clean the fan blades, which may have suctioned up dust or other small foreign bodies due to the static pressure exercised by the fan along the air ducts.
Clean the fan blades only with compressed air or with a vacuum cleaner. Take care not to damage the rotor or the fan blades.
Do not use any sort of rigid device which might bend the blades. When rotating, bent blades will produce more noise than normal due to off-axis rotation of the fan.
Chapter 4
page
17
4.1.2. Control unit FC 715
Does not require any special maintenance if located as instructed in
chapter 4.9.3.
From time to time, you may want to check the condition
of the fuse near the plug that provides power to the control unit.
4.1.3. Radio remote control
On a yearly basis, it is advisable to replace the batteries of the radio remote control to ensure efficient transmission of the data to the control unit. Check that the red light in the upper left-hand corner of the radio remote control comes on when buttons are pressed.
If for any reason (electromagnetic fields, voltage surges, etc.) the remote control stops transmitting data, to change the frequency, re­calibrate the frequency using the procedure in
, without necessarily moving the small switches located in the
4.11.6
chapter 4.10.4 or
battery compartment.
4.1.4. Probe
The probe does not require any maintenance. Just make sure that ashes or dirt do not build up around it. Ashes or dirt may act as insulation and invalidate the activation times of the device.
4.1.5. Wiring
ON
MAN
OFF
AUT
Make sure the wiring is in good condition and that it is not near the hot body of the fireplace stove. Heat may damage it.
4.2. CLEANING TO BE DEALT WITH BY SPECIALIZED TECHNICIAN
4.2.1. Cleaning flue pipe
Mechanical cleaning of the flue pipe is recommended at least once a year. Excessive deposits of unburnt solid material can cause problems with the evacuation of smoke, and gives rise to a risk of chimney fires.
Maintenance and cleaning Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited