Maytag MED3100DW Specification Sheet

DRYER DIMENSIONS
Front view:
383/4" Min.
(984 mm)
39" Max.
(990 mm)
Electric Dryer
PRODUCT MODEL NUMBERS
MED3100D, MED4100D, MED5100D, MED7100D, MED8100D
Side view:
27"
(686 mm)
Back view:
61/2"
(165 mm)
Power supply
cord/cable
7
29
/8"*
(759 mm)
1
3
/2"*
(89 mm)
1
6
/8"*
(156 mm)
Vent
3
/4"*
(18 mm)
* Approx. measurement
Water inlet
(Steam models only)
3
14
/8"
(365 mm)
NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”
* Approx. measurement
Recommended installation clearances (dryer only):
3"
(76 mm)
3"
(76 mm)
48 in.2 min.
(310 cm
24 in.2 min.
(155 cm2)
*
0" - 5"*
(0" - 127 mm)
(
18" min.
(457 mm)
*
1"*
(25 mm)
1"
(25 mm)
* 0" (0 mm) spacing is allowed.
2
)
Installation spacing for recessed area or closet installation
All dimensions show recommended and minimum spacing allowed.
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door, oor moldings, dryer venting, and gas line.
■ Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door
are required. Louvered doors with equivalent ventilation openings are acceptable.
■ Companion appliance spacing should also be considered.
W10676165B
02/2016
ELECTRICAL REQUIREMENTS
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or exible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Exhaust hoods:
Recommended Styles:
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and turns.
■ When using elbows or making turns, allow as much room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
Determine vent length and elbows needed for best drying performance:
■ Use the “Vent System Charts” on the next page to determine
type of vent material and hood combinations acceptable to use.
The “Vent System Charts” provide venting requirements that will help achieve best drying performance.
Standard Vent System Chart
Number of 90° elbows
0
1
2
3
4
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Angled
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Long Vent System Chart
Number of 90° elbows
0
1
2
3
4
To determine if your model has a long vent system, refer to the type code located on the serial number plate in the inner door well. Example: An electric model would be DALV – Ele – XXXX XXX-XXX.
NOTE: For long vent systems, use of box/louvered hoods will improve venting regardless of length.
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Angled
hoods
160 ft. (48.8 m)
150 ft. (45.7 m)
140 ft. (42.7 m)
130 ft. (39.6 m)
120 ft. (36.6 m)
NOTE: Do not use vent runs longer than those specied in “Vent System Charts.”
Exhaust systems longer than those specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.