Maxtor CV-M4CL Application Note

Matrox Meteor-II/Camera Link
Camera Interface Application Note
JAI CV-M4CL March 26, 2002
camera
Mode of operations as
per Matrox Imaging (in
parentheses as per
camera manufacturer)
interface modes
Camera Descriptions
§ Effective resolution: 1280 × 1024 × 10-bit @ 24 fps (Full resolution).
§ Camera Link BASE interface (single channel).
§ Progressive scan.
§ Internal or external sync.
§ Internal or external exposure control.
§ 40.49 MHz pixel clock rate.
Interface Mode
§ Continuous
§ Asynchronous reset
Camera Interface Briefs
Mode 1: Continuous
§ 1280 × 1024 × 10-bit @ 24 fps (Full resolution).
§ Camera Link BASE interface (single channel).
§ Progressive scan.
§ Matrox Meteor-II/Camera Link receiving LEN, FEN, Pclk and video data from
camera.
§ DCF used: CVM4CLC.DCF
Mode 2: Asynchronous reset (Pulse width control trigger)
§ 1280 × 1024 × 10-bit.
§ Camera Link BASE interface (single channel).
§ Progressive scan.
§ Matrox Meteor-II/Camera Link receiving external trigger signal.
§ Matrox Meteor-II/Camera Link sending EXPOSURE1 (CC1) signal to camera
to initiate and control exposure time.
§ Matrox Meteor-II/Camera Link receiving LEN, FEN, Pclk and video data from camera.
§ DCF used: CVM4CLA.DCF
MET2-CID-077
1
Matrox Meteor-II/Camera Link
Camera Interface Application Note
JAI CV-M4CL March 26, 2002
Specifics about the
interface modes
Camera Interface Details
Mode 1: Continuous
§ Frame Rate: Matrox Meteor-II/Camera Link receives the continuous video from the camera at 24 frames per second (Full resolution).
§ Exposure time: Exposure time is determined by the shutter setting. Refer to the camera manual for more information.
§ Camera switch settings: Refer to the camera manual for additional
information. Internal and external switches should be set as follows:
External Switches Internal Switches (SW50) Shutter 1 OFF 1 OFF Shutter 2 OFF 2 Shutter 3 OFF 3 OFF Shutter 4 OFF 4 OFF Ext. Trigger 5 OFF Ext. Trigger 6 OFF Scan 7 OFF Scan 8 OFF Smear-less 9 OFF Control 10 OFF
Mode 2: Asynchronous reset (Pulse width control trigger)
§ Frame Rate: The frame rate is determined by the frequency of the external trigger signal and the exposure time period.
§ Exposure time: The width (falling edge to rising edge) of the EXPOSURE1 (CC1) signal is the exposure time. The exposure time can be modified in the DCF using Matrox Intellicam, with the MIL MdigControl() function. Consult the respective manual for more information.
§ Camera switch settings: Refer to the camera manual for additional
information. Internal and external switches should be set as follows:
External Switches Internal Switches (SW50) Shutter 1 OFF 1 OFF Shutter 2 OFF 2 Shutter 3 OFF 3 OFF Shutter 4 OFF 4 OFF Ext. Trigger 5 Ext. Trigger 6 OFF Scan 7 OFF Scan 8 OFF Smear-less 9 OFF Control 10 OFF
ON
ON
ON
MET2-CID-077
2
Loading...
+ 1 hidden pages