Maxtor Cohu 4110 Application Note

Application Note:
Interfacing non-standard cameras to Matrox Pulsar
Cohu 4110 July 31, 1996
Camera Interface Overview
Camera Interface Details
739 x 484 x 8-bit
digital video output (RS-422)
internal hsync, vsync (RS-422)
internal and external pixel clock signals (RS-422)
pixel clock rate: 10 MHz or 14.3 MHz
external exposure control
modes of operation: continuous (normal and multiple vertical reset), and shutter
1. Continuous mode
Video
Cohu
4110
740 x 480 x 8-bit
continuous video digital output (8-bit, RS-422)
pixel clock: 14.318 MHz
DCFs used: 4110D.DCF
HSync
VSync
Clkin
Clkout
Matrox Pulsar
(with PULSAR/DIG/MOD)
Cabling Requirements
1. Continuous mode
PULSAR/DIG/MOD required for digital data in RS-422 format
the following connections should be made between the DB-44 connector of the camera and
the 68-pin SCSI-2 connector of PULSAR/DIG/MOD
PULSAR/DIG/MOD Cohu 4110
(PLS/CBL/OPEN connector ) (DB-44 plug)
Pin name Pin no. Pin name Pin no.
CLKOUT+ 24 CLOCKIN+ 2 CLKOUT- 58 CLOCKIN- 1 DATA0+ 20 DATA0+ 8 DATA1+ 19 DATA1+ 9 DATA2+ 16 DATA2+ 10 DATA3+ 15 DATA3+ 11 DATA4+ 14 DATA4+ 12 DATA5+ 13 DATA5+ 13 DATA6+ 11 DATA6+ 14 DATA7+ 10 DATA7+ 15 DATA0- 54 DATA0- 23 DATA1- 53 DATA1- 24 DATA2- 50 DATA2- 25 DATA3- 49 DATA3- 26
(pin-out continued)
Application Note:
Interfacing non-standard cameras to Matrox Pulsar
Cohu 4110 July 31, 1996
Cabling Requirements (Continued)
Special Considerations
PULSAR/DIG/MOD Cohu 4110 (PLS/CBL/OPEN connector) (DB-44 plug)
Pin name Pin no. Pin name Pin no.
DATA4- 48 DATA4- 27 DATA5- 47 DATA5- 28 DATA6- 45 DATA6- 29 DATA7- 44 DATA7- 30 HSYNC+ 26 ENABLE LINE + 34 HSYNC- 60 ENABLE LINE - 19 VSYNC+ 25 ENABLE FRAME + 35 VSYNC- 59 ENABLE FRAME - 20 GROUND 12 GROUND, DIGITAL 7 GROUND 46 GROUND, DIGITAL 22 GROUND 68 GROUND 36 TTL_USR0 31 INT/EXT 40 CLKIN+ 29 CLOCKOUT+ 31 CLKIN- 63 CLOCKOUT- 16
Use Matrox Intellicam in order to modify the DCF for RS-422 external trigger input.
Consult the Matrox Intellicam User Guide for more information. Contact your local sales representative or Matrox Sales Office, or contact Matrox Imaging Applications at 514­822-6061 for assistance (if required).
The DCF(s) mentioned in this application note can be found on the MIL and MIL-Lite CD, or our FTP site (ftp.matrox.com). The information furnished by Matrox Electronics System, Ltd. is believed to be accurate and reliable. Please verify all interface connections with camera documentation or manual. Contact your local sales representative or Matrox Sales office or Matrox Imaging Applications at 514-822-6061 for assistance.
CorporateCorporate Headquarters:Headquarters: Canada and U.S.A.Canada and U.S.A. Matrox ElectronicMatrox Electronic Systems Ltd.Systems Ltd.
1055 St.Regis Blvd. Dorval, Quebec, Canada H9P 2T4 Tel: (514) 685-7230 Fax: (514) 822-6273
Sales Offices:Sales Offices: U.K.U.K.
Matrox (UK) Ltd.Matrox (UK) Ltd.
Sefton Park, Stoke Poges Buckinghamshire U.K. SL2 4JS Tel: +44 (0) 1753 665500 Fax: +44 (0) 1753 665599
FranceFrance Matrox France SARLMatrox France SARL
2, rue de la Couture, Silic 225 94528 Rungis Cedex Tel: (0) 1 45-60-62-00 Fax: (0) 1 45-60-62-05
GermanyGermany Matrox GmbHMatrox GmbH
Inselkammerstr.8 D-82008 Unterhaching Germany Tel: 089/614 4740 Fax: 089/614 9743
Asia PacificAsia Pacific Matrox Asia LiaisonMatrox Asia Liaison OfficeOffice
Rm. 1901, 19/F, Workington Tower, 78 Bonham Strand E., Sheung Wan, Hong Kong. Tel: 852.2877.5387 Fax: 852.2537.9530
PUL-CID-025