Maxtor CAM1351 Application Note

Application Note:
Interfacing non-standard cameras to Matrox Pulsar
Loral Fairchild CAM1351 03/06/96
Camera Interface Overview
Camera Interface Details
1024 x 1 x 8-bit
analog video output
mode of operation: variable line scan rate with external exposure control
Variable line scan rate with external exposure control
Video
Data rate in
LORAL C. 1351
1024 x 1 x 8-bit
analog video output
DCF configured for 800 lines per virtual frame
the line scan rate is determined by the frequency of the EXPOSURE1 (Line/Integrate)
Data rate out
Line/Integrate
e
Line sync out
TTL external trigger
Matrox Pulsar
(with PLS-TTL-CABLE)
signal, which is the frequency of the external trigger signal. The exposure time is the duration of the low cycle of the Line/Integrate signal. The exposure time can be altered by modifying the low period of the EXPOSURE1 signal provided by the Pulsar; this is accomplished through the use of Intellicam
Matrox Pulsar receiving TTL external trigger
Matrox Pulsar sending RS-422 EXPOSURE1 (Line/Integrate) and RS-422 pixel clock
(Data rate in @ 20MHz) signals to camera; the EXPOSURE1 signal initiates line readout and controls exposure time
camera returning RS-422 pixel clock (Data rate out) and RS-422 hsync (Line sync out)
signals to Matrox Pulsar
DCF used: CA1351AL.DCF
Cabling Requirements
Variable line scan rate with external exposure control
IMG-7W2-TO-5BNC cable required for video signal and TTL external trigger source;
PLS-TTL-CABLE required for digital syncs and control signals in RS-422 format
the connections between the DB-15 connector on the rear panel of the camera and the
DB-37 connector of the PLS-TTL-CABLE are as follows:
Loral Fairchild CAM1351 PLS-TTL-CABLE (DB-15 male connector) (DB-37 female connector) Pin name Pin no. Pin name Pin no.
DATA RATE IN+ 6 ← CLKOUT+ 24 DATA RATE IN− 13 ← CLKOUT− 5 DATA RATE OUT+ 8 → CLKIN+ 4 DATA RATE OUT− 15 → CLKIN− 22 LINE/INTEGRATE+ 5 EXPOSURE1+ 21 LINE/INTEGRATE12 EXPOSURE12 LINE SYNC OUT+ 7 → HSYNC+ 16 LINE SYNC OUT− 14 → HSYNC− 34
Application Note:
Interfacing non-standard cameras to Matrox Pulsar
Loral Fairchild CAM1351 03/06/96
the connections between the DB-15 connector on the rear panel of the camera and the
power supply are as follows:
Loral Fairchild CAM1351 (DB-15 male connector) POWER SUPPLY Pin no. Pin name
4&11 +5V +5V
9 +15V +15V 2 15V 15V
3&10 GND GND
TTL external trigger source should be connected to the TTL Trigger Input of the IMG-
7W2-TO-5BNC cable
Special Considerations
Variable line scan rate with external exposure control
in addition to the DCFs, PSG FPGA version 3.01 or newer is required; if this version is
not on your release of the MIL driver for Pulsar, the newest version can be found on the BBS or at the FTP site
once it has received the external signal to trigger, the Pulsar sends the RS-422
EXPOSURE1 (Line/Integrate) signal to the camera. The camera awaits the falling edge of the signal and exposes for as long as the signal is low. The rising edge of the signal initiates line readout; the readout of a line of data is delayed by 1 or 2 clock cycles from the arrival of the rising edge of the EXPOSURE1 signal
the line scan rate is determined by the frequency of the Line/Integrate (EXPOSURE1)
signal, which is the frequency of the external trigger signal. The time between external trigger signals must be greater than the sum of the exposure time and the line transfer time (51.2µs)
The exposure time is the duration of the low cycle of the Line/Integrate signal; the
exposure time can be altered by modifying the low period of the EXPOSURE1 signal provided by the Pulsar. The width of the low portion of this signal can be adjusted though the use of Intellicam: load CA1351AL.DCF and go into Camera Spec. Editor. Move the cursor down to EXPOSURE such that the words “generated on trigger” are selected and press enter; an interface entitled “Exposure signal information” will open. The exposure time can be modified by changing the time specified for T pulse width. Under the heading of sec., select the exposure time in seconds; the value of T pulse width must be greater than 2 clock cycles, which corresponds to 0.1µs for a pixel clock of 20MHz. To complete this operation by accepting and computing the registers etc., follow the instructions in the Intellicam User Guide. The default setting of the exposure time is 1.5ms, thus the external trigger rate for the current settings of the DCF must not exceed 645Hz
continued
PUL-CID-021 2