Contact information
This installation and maintenance manual is a component part of the scope of delivery. It must be kept in a safe place and remain with the equipment in the event of resale.
We reserve the right to make technical improvements to the products described in this installation and maintenance manual without notification.
Reprinting, translation and copying of this document, or extracts of it, by any means requires the written approval of the publisher.
Copyright remains with the publisher. This installation and maintenance manual is
not subject to an updating service. Information on the current status is available
from
MANN+HUMMEL GMBH Geschäftsbereich Industriefilter Brunckstr. 15 D - 67346 Speyer Internet: http://www.mann-hummel.com/ E-mail: if.info@mann-hummel.com
Contents
1 Foreword ............................................................ 2
2 Scope of Delivery .............................................. 2
3 Safety.................................................................. 3
3.1 Warning labels and symbols ...................... 3
3.2 Intended use ............................................... 3
3.3 Operating safety ......................................... 3
4 Function Description ........................................ 3
5 Installation ......................................................... 6
5.1 General information .................................... 6
5.2 Securing the filter ....................................... 6
6 Maintenance ...................................................... 7
6.1 Maintenance plan ....................................... 8
6.2 Maintenance of the main filter element ...... 8
6.2.1 Disassembling the main filter element ... 8
6.2.2 Cleaning the main filter element ............ 8
6.2.3 Installing the main filter element ............ 9
6.3 Maintenance of the secondary element ..... 9
6.3.1 Disassembling the main filter element ... 9
6.3.2 Changing the secondary element .......... 9
6.3.3 Installing the main filter element .......... 10
6.4 Maintenance of the cyclone block ............ 10
7 Storing Filter Elements ................................... 10
8 Troubleshooting .............................................. 11
9 Disposing of Parts .......................................... 12
1 Foreword
This installation and maintenance manual serves to help you become familiar with the IQORON and its intended use.
This installation and maintenance manual contains important information on operating the components safely, properly and economically. Observation of the manual helps avoid potential risks, reduce repair costs and downtimes as well as improve machine reliability and increase its service life.
The manual must be available to every person charged with working on the filter.
Where necessary, this manual must be supplemented by instructions containing existing national laws on accident prevention and environmental protection (particularly in respect of disposing of disassembled parts).
We reserve the right to make technical modifications to the filter and/or alter the content of this installation and maintenance manual without notification.
Information for the operator:
The operator is responsible for the provision of working equipment complying with basic health and safety requirements in accordance with the Ordinance on Industrial Safety and Health. This also includes deploying the work equipment such that it is only used within the scope of its intended use. The operator can define individual maintenance and service plans and intervals in addition to those stipulated in the installation and maintenance manual.
2 Scope of Delivery
The delivery contains the 3-piece air filter housing with main filter element and dust discharge valve. The filter is delivered fully assembled.
The maintenance indicator and secondary filter element are optionally available and,
MANN+HUMMEL IQORON
MANN+HUMMEL Industrial Filters
3
therefore, not automatically supplied as a component part of the delivery.
Compare the part number on the delivery with that in our catalogue. Order the optional parts, if necessary.
3 Safety
3.1 Warning labels and symbols
This symbol appears in all the sections of the manual in which the information provided must be strictly observed to prevent damage or destruction of system parts.
This symbol appears in all the sections of the manual in which the information provided must be carefully observed to ensure trouble-free, economic operation.
3.2 Intended use
The IQORON has been constructed according to state-of-the-art technology and accepted safety-related regulations. However, the functional safety of connected equipment can be at risk when:
the IQORON is used improperly, the operating conditions have changed, reconstructions have been made without
prior consultation with the manufacturer, the necessary maintenance and repair work
has been neglected.
The IQORON may only be used when it is in a technically safe working condition and for its intended use, taking the relevant technical design, safety and risk aspects into account and observing the information in the installation and maintenance manual! Investigate faults (or have them investigated) immediately, particularly those which could impair safety!
The IQORON has been exclusively designed for the mechanical filtration of air. An other use above or beyond this, such as filtering
aggressive, combustible and/or explosive materials, is considered unintended use.
The manufacturer/supplier is not considered liable for damage resulting from unintended use.
Intended use also includes observing the information in the installation and maintenance manual and meeting all the inspection and maintenance conditions.
3.3 Operating safety
The IQORON may only be serviced and operated by appropriately trained, authorized personnel.
The operator is obliged to inspect the IQORON once a week for visible signs of damage and defects. Any changes (including those in the operating behaviour) which could affect functional safety must be reported immediately.
All labels and identifications on the IQORON must be kept in legible condition.
4 Function Description
The IQORON is a single-stage dry air filter intended to clean the intake air of air aspirating machines of all types (e.g. engines, compressors, fans).
The air drawn in initially flows through the cyclone block (Pos. 3). The cyclone cells filter out 95% of the particulate matter. This pre­filtered particulate matter must be drawn off, e.g. by an ejector, at the dust discharge connection (Pos. 5). This pre-filtering process (filter stage 1) makes the IQORON particularly suitable for use in applications which involve large amounts of dust.
The cleaned air then flows through the main filter element (2nd filter stage Pos. 2) and downstream secondary element (option, Pos.
10) to the clean air connection (Pos. 8). The filter elements form a seal when assembled due to their shape. This shaping has the following advantages:
minimal assembly and disassembly forces, defined contact forces for the seals,
MANN+HUMMEL IQORON
MANN+HUMMEL Industrial Filters
4
high level of protection against penetration by dust.
In addition to the clean air connection (Pos.
8), there is also an adapter (M10x1, Pos. 7) to connect a maintenance indicator or switch. The maintenance indicator/switch indicates when the vacuum produced by the suction has exceeded a prescribed value (e.g. +50 mbar). This means that the prescribed maximum filter flow resistance has been exceeded and the filter must be serviced.
The secondary element (Pos.10) protects the engine from penetration by dust during maintenance and, to a certain extent, during operation with a main filter element damaged through improper handling. A secondary element can be retrofitted on the IQORON at any time.
Operation with only a secondary element is not permitted and can lead to engine damage!
Fig. 1 IQORON, size 7
Pos.
Name
Pos.
Name
1
Lid
6 Housing
2
Main filter element
7 Connection for maintenance indicator/switch
3
Cyclone block
8 Clean air connection
4
Allen screw
9 Wire clamp fastener
5
Dust discharge connection
10
Secondary element
1 2 3 4 5 6 7 8 9