Safety Notices
Procedural Notices
As you work on an S Model Series Ice Machine, be sure
to pay close attention to the safety notices in this
manual. Disregarding the notices may lead to serious
injury and/or damage to the ice machine.
Throughout this manual, you will see the following types
of safety notices:
!
Warning
PERSONAL INJURY POTENTIAL
Do not operate equipment that has been misused,
abused, neglected, damaged, or altered/modified
from that of original manufactured specifications.
Warning
!
Text in a Warning box alerts you to a potential
personal injury situation. Be sure to read the
Warning statement before proceeding, and work
carefully.
Caution
!
Text in a Caution box alerts you to a situation in
which you could damage the ice machine. Be sure
to read the Caution statement before proceeding,
and work carefully.
As you work on an S Model Series Ice Machine, be sure
to read the procedural notices in this manual. These
notices supply helpful information which may assist you
as you work.
Throughout this manual, you will see the following types
of procedural notices:
Important
Text in an Important box provides you with
information that may help you perform a procedure
more efficiently. Disregarding this information will
not cause damage or injury, but it may slow you
down as you work.
NOTE: Text set off as a Note provides you with simple,
but useful, extra information about the procedure you
are performing.
Read These Before Proceeding:
Caution
!
Proper installation, care and maintenance are
essential for maximum ice production and troublefree operation of your Manitowoc Ice Machine.
Read and understand this manual. It contains
valuable care and maintenance information. If you
encounter problems not covered by this manual, do
not proceed, contact Manitowoc Ice, Inc. We will be
happy to provide assistance.
Important
Routine adjustments and maintenance procedures
outlined in this manual are not covered by the
warranty.
NOTE: Model numbers ending in 3 indicate a 3-phase
unit. Example: SY0605WM3
Warning
!
PERSONAL INJURY POTENTIAL
Do not operate equipment that has been misused,
abused, neglected, damaged, or altered/modified
from that of original manufactured specifications.
Warning
!
PERSONAL INJURY POTENTIAL
Remove all ice machine panels before lifting and
installing.
How to Read a Model Number
# CUBE SIZE
3 DICE
5 HALF-DICE
CONDENSER TYPE
WATER-COOLED
WATER-COOLED
S Y 0605 W M
ICE MACHINE
MODEL
ICE CUBE SIZE
D DICE
Y HALF DICE
ICE MACHINE
SERIES
CONDENSER TYPE
W SELF-CONTAINED WATER-COOLE
Ice Cube Sizes
Regular
1-1/8" x 1-1/8" x 7/8"
2.86 x 2.86 x 2.22 cm
Dice
7/8" x 7/8" x 7/8"
2.22 x 2.22 x 2.22 cm
MARINE MODE
Half Dice
3/8" x 1-1/8" x 7/8"
0.95 x 2.86 x 2.22 cm
Part Number 80-1629-31-1
General InformationSection 1
Accessories
Contact your Manitowoc distributor for these optional
accessories:
BIN CASTER
Replaces standard legs.
ICE BAGGER
Maximize profits from bagged ice sales with this
convenient accessory. This sturdy unit rests on the bin
door frame, and adapts for left or right side filling.
GUARDIAN™ SACHET PACKETS
Guardian sachet packets release chlorine dioxide on a
controlled basis to inhibit the growth of bacteria and
slime.
Guardian sachet packets are available through your
local Manitowoc Ice Machine dealer.
ARCTIC PURE™ WATER FILTER SYSTEM
Engineered specifically for Manitowoc ice machines,
This water filter is an efficient, dependable, and
affordable method of inhibiting scale formation, filtering
sediment, and removing chlorine taste and odor.
MANITOWOC CLEANER AND SANITIZER
Manitowoc Ice Machine Cleaner and Sanitizer are
available in convenient 16 oz. (473 ml) bottles. These
are the only cleaner and sanitizer approved for use with
Manitowoc products.
This accessory reduces equipment cleaning expense.
The AuCS® accessory monitors ice making cycles and
initiates cleaning procedures automatically.
DISPENSER
A counter-top dispenser is ideal for cafeterias and many
types of self-service facilities. Manitowoc auto-fill, floorstanding ice dispensers meet the strict sanitary
requirements of the food service, lodging and health
care industries.
1-2
Part Number 80-1629-3
Section 1General Information
Model/Serial Number Location
These numbers are required when requesting
information from your local Manitowoc distributor, or
Manitowoc Ice, Inc.
SV13147
The model and serial number are listed on the MODEL/
SERIAL NUMBER DECAL affixed to the ice machine,
remote condenser and storage bin.
MODEL/SERIAL DECAL
LOCATION
Model/Serial Number Location
Part Number 80-1629-31-3
General InformationSection 1
Owner Warranty Registration Card
GENERAL
The packet containing this manual also includes
warranty information. Warranty coverage begins the day
your new ice machine is installed.
Important
Complete and mail the OWNER WARRANTY
REGISTARATION CARD as soon as possible to
validate the installation date.
If you do not return your OWNER WARRANTY
REGISTRATION CARD, Manitowoc will use the date of
sale to the Manitowoc Distributor as the first day of
warranty coverage for your new ice machine.
Warranty Coverage
GENERAL
The following Warranty outline is provided for your
convenience. For a detailed explanation, read the
warranty bond shipped with each product.
Contact your local Manitowoc Distributor, Manitowoc Ice,
Inc. or visit our website at www.manitowocice.com if you
need further warranty information.
Important
This product is intended exclusively for commercial
application. No warranty is extended for personal,
family, or household purposes.
PARTS
1. Manitowoc warrants the ice machine against defects
in materials and workmanship, under normal use
and service for three (3) years from the date of
original installation.
2. The evaporator and compressor are covered by an
additional two (2) year (five years total) warranty
beginning on the date of the original installation.
LABOR
1. Labor required to repair or replace defective
components is covered for three (3) years from the
date of original installation.
2. The evaporator is covered by an additional two (2)
year (five years total) labor warranty beginning on
the date of the original installation.
EXCLUSIONS
The following items are not
warranty coverage:
1. Normal maintenance, adjustments and cleaning.
2. Repairs due to unauthorized modifications to the
ice machine or use of non-standard parts without
prior written approval from Manitowoc Ice, Inc.
3. Damage caused by improper installation of the ice
machine, electrical supply, water supply or drainage,
or damage caused by floods, storms, or other acts of
God.
4. Premium labor rates due to holidays, overtime,
etc.; travel time; flat rate service call charges;
mileage and miscellaneous tools and material
charges not listed on the payment schedule.
Additional labor charges resulting from the inaccessibility of equipment are also excluded.
5. Parts or assemblies subjected to misuse, abuse, neglect or accidents.
6. Damage or problems caused by installation,
cleaning and/or maintenance procedures
inconsistent with the technical instructions
provided in this manual.
7. This product is intended exclusively for
commercial application. No warranty is extended
for personal, family, or household purposes.
AUTHORIZED WARRANTY SERVICE
To comply with the provisions of the warranty, a
refrigeration service company qualified and
authorized by a Manitowoc distributor, or a
Contracted Service Representative must perform the
warranty repair.
NOTE: If the dealer you purchased the ice machine from
is not authorized to perform warranty service, contact
your Manitowoc distributor or Manitowoc Ice, Inc. for the
name of the nearest authorized service representative.
Service Calls
Normal maintenance, adjustments and cleaning as
outlined in this manual are not covered by the
warranty. If you have followed the procedures listed on
page 5-1 of this manual, and the ice machine still does
not perform properly, call your authorized service
company.
included in the ice machine’s
1-4
Part Number 80-1629-3
Section 2Installation Instructions
A
Section 2
Installation Instructions
General
These instructions are provided to assist the qualified
installer. Check your local Yellow Pages for the name of
the nearest Manitowoc distributor, or call Manitowoc Ice,
Inc. for information regarding start-up services.
Ice Machine Dimensions
S600M WATER-COOLED ICE MACHINES
Failure to follow these installation guidelines may
affect warranty coverage.
H
Important
B
2.61"
(6.62cm)
1.81"
(4.59cm)
1.50" (3.81cm)
8.50" (21.60cm)
5.06" (12.85cm)
6.68" (16.96cm)
7.75" (19.7 cm)
17.25" (43.81 cm)
6.50" (16.5cm)
W
2.85" (7.30cm)
4.25" (10.81 cm)
D
ELECTRICAL
AUCS
CONNECTIONS
AUXILLARY BASE DRAIN
1/2"CPVC SOCKET
WATER INLET
3/8"FPT
DRAIN 1/2"NPTF
CONDENSER WATER
OUTLET 1/2"FPT
(Water-Cooled Only)
CONDENSER WATER
INLET 3/8"FPT
(Water-Cooled Only)
Ice MachineDimension ADimension BDimension WDimension DDimension H
S600M11.5 in (29.2 cm)9.0 in (22.9 cm)30 in. (76.2 cm)24.50 in. (62.2 cm)21.5 in (54.6 cm)
Part Number 80-1629-32-1
Installation InstructionsSection 2
Location of Ice Machine
The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
•The location must be free of airborne and other
contaminants.
•The air temperature must be at least 35°F (1.6°C),
but must not exceed 110°F (43.4°C).
•The location must not be near heat-generating
equipment or in direct sunlight and must be protected
from weather.
•The location must not obstruct air flow through or
around the ice machine. Refer to the chart below for
clearance requirements.
S600MWater-Cooled*
Top/Sides8" (20.3 cm)
Back5" (12.7 cm)
*There is no minimum clearance required for water-cooled or
remote ice machines. This value is recommended for efficient
operation and servicing only.
Ice Machine Heat of Rejection
Series
Ice Machine
S600M900013900
B.T.U./Hour
Because the heat of rejection varies during the ice making cycle,
the figure shown is an average.
Air Conditioning
Heat of Rejection
Ice machines, like other refrigeration equipment, reject
heat through the condenser. It is helpful to know the
amount of heat rejected by the ice machine when sizing
air conditioning equipment where self-contained aircooled ice machines are installed.
This information is also necessary when evaluating the
benefits of using water-cooled or remote condensers to
reduce air conditioning loads. The amount of heat added
to an air conditioned environment by an ice machine
using a water-cooled or remote condenser is negligible.
Knowing the amount of heat rejected is also important
when sizing a cooling tower for a water-cooled
condenser. Use the peak figure for sizing the cooling
tower.
Peak
Caution
!
The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C).
Failure caused by exposure to freezing
temperatures is not covered by the warranty. See
“Removal from Service/Winterization”.
2-2
Part Number 80-1629-3
Section 2Installation Instructions
Electrical Service
GENERAL
Warning
!
All wiring must conform to local, state and national
codes.
VOLTAG E
The maximum allowable voltage variation is ±10% of the
rated voltage at ice machine start-up (when the electrical
load is highest).
Observe correct polarity of incoming line voltage.
Fuse/Circuit Breaker
A separate fuse/circuit breaker must be provided for
each ice machine. Circuit breakers must be H.A.C.R.
rated (does not apply in Canada).
MINIMUM CIRCUIT AMPACITY
The minimum circuit ampacity is used to help select the
wire size of the electrical supply. (Minimum circuit
ampacity is not the ice machine’s running amp load.)
Important
!
Warning
The ice machine must be grounded in accordance
with national and local electrical codes.
S Series Ice Machines (* indicates preliminary data)
Ice Machine
S600M
Voltage Phase
Cycle
208-230/1/60157.9
230/1/50156.1
The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must be
determined by a qualified electrician.
ELECTRICAL REQUIREMENTS
Refer to Ice Machine Model/Serial Plate for voltage/
amperage specifications.
Water Cooled
Maximum Fuse/Circuit
Breaker
Minimum Circuit Amps
Part Number 80-1629-32-3
Installation InstructionsSection 2
Self-Contained Electrical Wiring Connections
!
Warning
These diagrams are not intended to show proper
wire routing, wire sizing, disconnects, etc., only the
correct wire connections.
All electrical work, including wire routing and
grounding, must conform to local, state and national
electrical codes.
Though wire nuts are shown in the drawings, the ice
machine field wiring connections may use either
wire nuts or screw terminals.
SELF CONTAINED ICE MACHINE
115/1/60 OR 208-230/1/60
L
1
N=115V
OR
L2=208-230V
GROUND
GROUND
SELF CONTAINED ICE MACHINE
208-230/3/60
L
1
L
2
L
3
GROUND
ICE MACHINE
SV1190
L
1
CONNECTIONS
TO SEPARATE
FUSE/BREAKER
GROUND
L
1
L
2
L
3
SELF CONTAINED ICE MACHINE
230/1/50
L
1
L
1
SV1258
ICE MACHINE
CONNECTIONS
TO SEPARATE
FUSE/BREAKER
SV1191
N
GROUND
ICE MACHINE
CONNECTIONS
GROUND
TO SEPARATE
FUSE/BREAKER.
DISCONNECT ALL
POLES.
For United Kingdom Only
As the colors of the wires in the mains lead of the appliance may not correspond with the colored markings
identifying the terminals in your plug, proceed as follows:
•The wire which is colored green and yellow
the letter E or by the earth ground symbol or colored green or green and yellow.
•The wire colored blue
•The wire colored brown
must be connected to the terminal which is marked with the letter N or colored black.
must be connected to the terminal which is marked with the letter L or colored red.
must be connected to the terminal in the plug which is marked with
N
2-4
Part Number 80-1629-3