Note: Bin must be level before installation of ice machine.
1. Apply foam tape across front & back bin surfaces.
2. Place RH & LH panels on bin as shown. Line up back edge of pane ls with back of bin. Use holes in panels to dr ill holes for screws; use a 5/32” drill bit.
CAUTION
Do not drill through bin liner.
3. Place front support and back support on top of panels, line up slots in supports with holes in panels. Install supplied screws but do not tighten completely.
4. Place ice machine on surfaces shown. Snug up front and back supports to ice machine base, tighten all screws.
5. Fill all gaps/seams with provided foam tape. Use food gra de RTV sealant along intersections and the inside edge of the foam tape to prevent water tracking.