Manitowoc Ice RF0266A PARTS LIST

Page 1
For more Parts Information:
https://manitowocfsg.sysonline.com/Default.aspx
Page 2
TABLE OF CONTENTS
i
Page 3
RF0266
RF0266 EVAPORATOR ASSEMBLY
RF-0266_3.PDF
1
Page 4
RF0266
RF0266 EVAPORATOR ASSEMBLY
# PART # DESCRIPTION QTY Note 1 000005684 Evaporator Assembly
2 000005693 Evaporator Foundation 2a 000012459 Bolt - Evaporator Foundation - M6 x 25mm 3 Gear Motor Assembly 3a 000011126 Gearmotor Assembly - 115V/60 Hz/1 Ph 3b 000011800 Gearmotor Assembly - 208-230V/50-60 Hz/1 Ph 4 Gearmotor Capacitor 4a 000007825 Gearmotor Capacitor - 115V/60 Hz/1 Ph 4b 000007824 Gearmotor Capacitor - 230V/50 Hz/1 Ph 4c 000007826 Gearmotor Capacitor - 220V/60 Hz/1 Ph 5 000005642 Coupling 6 000005734 Insulating Cap 7 000005608 Bearing Cap 8 000005757 Snap Ring 9 000005599 Auger Bolt 10 000005609 Bearing Shim 11 000005650 Self Lubricating Disc 12 000005607 Upper Bearing 13 000005735 Upper O-ring 14 000005647 Cutter Head 15 000005598 Auger 16 000005778 Water Seal 17 000005681 Evaporator 18 000005583 O-ring Gasket 19 000005782 Water Seal Retainer 20 000005605 Lower Bearing
RF-0266_3.PDF
2
Page 5
RF0266
RF0266 EVAPORATOR COMPARTMENT
RF-0266_2.PDF
3
Page 6
RF0266
RF0266 EVAPORATOR COMPARTMENT
# PART # DESCRIPTION QTY Note 1 Compressor [1]
1a 000011956 Compressor - Embraco - 115V/60 Hz/1 Ph [2] 1b 000005615 Compressor - Tecumseh - 115V/60 Hz/1 Ph [3] 1c 000005616 Compressor - Tecumseh - 230V/60 Hz/1 Ph 1d 000005614 Compressor - Tecumseh - 230V/50 Hz/1 Ph 2 Compressor Overload - See Note for Usage 2a 000012336 Overload - 115V/60 Hz/1 Ph [4] 2b 000008400 Overload - 115V/60 Hz/1 Ph [5] 2c 000008401 Overload - 230V/50 Hz/1 Ph 3 Compressor Delay Relay 3a 000005746 Compressor Delay Relay - 115V/60 Hz/1 Ph 3b 000005745 Compressor Delay Relay - 230V/50-60 Hz/1 Ph 4 Compressor Start Relay [6] 4a 000008384 Compressor Start Relay - 115V/60 Hz/1 Ph 4b 000008383 Compressor Start Relay - 230V/50 Hz/1 Ph 5 Start Relay 5a 000008381 Start Relay - 208-230V/50-60 Hz/1 Ph 6 Start Capacitor - See Note for Usage 6a 000012337 Start Capacitor - 115V/60 Hz/1 Ph [4] 6b 000008426 Start Capacitor - 115V/60 Hz/1 Ph [5] 6c 000008425 Start Capacitor - 230V/50 Hz/1 Ph 7 Condenser Fan Motor 7a 000005578 Fan Motor - 115V/60 Hz/1 Ph 7b 000005574 Fan Motor - 208-230V/50-60 Hz/1 Ph 8 000005629 Air Condenser 9 000012450 Water Reservoir Assembly [7] 10 000005768 Evaporator Safety Thermostat 11 000005766 Bin Thermostat 12 Fan Cycle Control 12a 000006060 Fan Cycle Control - 115-230V/50-60 Hz/1 Ph 13 000006069 ON/OFF Rocker Switch 14 000005680 Electronic Noise Reducer [8] 15 000005760 Float Microswitch (each) 16 Water Inlet Valve 16a 000006063 Water Inlet Valve - 115V/60 Hz/1 Ph 16b 000005770 Water Inlet Valve - 220-230V/50-60 Hz/1 Ph 17 000005674 Drier 18 000009160 Evaporator Drain Tap [9] 19 Condenser Fan Blade 19a 000005687 Condenser Fan Blade - 60 Hz 19b 000005688 Condenser Fan Blade - 50 Hz 20 Access Valve
RF-0266_2.PDF
4
Page 7
RF0266
RF0266 EVAPORATOR COMPARTMENT
# PART # DESCRIPTION QTY Note 20a 000006408 Fitting - Access Valve
20b 000006409 Core - Access Valve 20c 000006410 Cap - Access Valve 21 Screws 21a 000009040 Screw - M5 x 10TC [10] 21b 000009041 Screw - 3.9 x 13TC [10] 22 Backflow Preventer 22a 000009971 Backflow Preventer 60 Hz - 3/8" 22b 000009972 Backflow Preventer 50 Hz - 3/4"
PART NOTES:
[1] - Tecumseh 115V compressors are no longer available. Verify compressor prior to replacing start
[2] - When replacing a Tecumseh compressor with an Embraco compressor the start components must be [3] - Discontinued - Replace with Embraco Compressor & Start Components
[4] - Used with Embraco compressors. Verify compressor prior to replacing start components. DO NOT [5] - Used with Tecumseh compressors. Verify compressor prior to replacing start components. DO NOT [6] - mounts on Tecumseh compressor
[7] - Includes Reservoir, Hoses, Clamps, Drain Tap & Two Microswitches [8] - radio interference filter [9] - when used [10] - No Longer Available
components. Replace Embraco compressor/start components with a Embraco compressor/start components. DO NOT INTERCHANGE COMPRESSORS OR START COMPONENTS.
replaced. DO NOT INTERCHANGE COMPRESSORS OR START COMPONENTS.
INTERCHANGE COMPRESSORS OR START COMPONENTS. INTERCHANGE COMPRESSORS OR START COMPONENTS.
RF-0266_2.PDF
5
Page 8
RF0266
RF0266 PANELS
RF-0266_4.PDF
6
Page 9
RF0266
RF0266 PANELS
# PART # DESCRIPTION QTY Note 1 000005741 Top Panel
2 000005611 Ice Spout Cover Bracket 3 000005740 Back Panel Assembly 4 000005700 Back Grill 5 Foamed Cabinet Assembly 5a 000006071 Foamed Cabinet Assembly 115/60/1 5b 000006081 Foamed Cabinet Assembly - 230V/50-60 Hz/1 Ph 6 000006077 Front Grill Panel 7 000005601 Base Plate 8 000005659 Door Assembly 9 000005783 Plastic Legs 10 000005663 Adjustable Stainless Steel Legs 11 000006162 Drain Manifold - 115V/60 Hz/1 Ph 12 000005581 Bin Drain Nut 13 000005695 Bin Drain Gasket Bottom 14 000005696 Bin Drain Gasket Top 15 000005692 Bin Drain Fitting 16 000006075 Bin Bulb Holder
RF-0266_4.PDF
7
Loading...