K00152 KEY CARD KIT
Installation Instructions
Parts List
Quantity Part Number Description
Item
1. 1 2032623 Wiring Harness
2. 1 2502183 Bushing - Heyco
3. 1 5202063 Sheet Metal Screw
4. 2 5428781 #6 Hex Nut
5. 4 5429061 #8 Hex Nut
6. 2 5544541 #6 Lock Washer
7. 4 5544591 #8 Lock Washer
8. 1 6028781 Switch Cover
9. 1 6028861 Key Card Weldment
10. 1 6269914 Key Card Access Plate Studweld
11. 1 6270314 Access Switch
12. 1 8011233 Instruction Sheet
13. 1 8132303 Label - Insert Room Key Card
14. 1 8136153 Label - Wiring Diagram
Instructions
1. Disconnect power.
2. Cut out and tape hole pattern to outside of dispenser door.
3. Use a sharp punch to mark all six holes.
4. Remove pattern from dispenser door.
5. Drill six 1/4” diameter holes through the door liner using punch marks.
6. Cut out material between the two middle holes, as shown on pattern.
7. Insert the studs on the key card access plate into the four mounting holes from the front side.
8. Assemble the access switch assembly to the studs with the lock washers and #8-32 hex nuts (see diagram 1).
9. Disconnect the switch wire harness and plug the male end of the key card assembly wire harness in its place.
10. Plug the switch wire harness into the female end of the key card assembly wire harness.
11. Attach the wiring diagram sticker to wiring diagram on the control box cover (see diagram 2).
12. Attach switch cover to the key card assembly with sheet metal screw (see diagram 1).
13. Connect power and test. Insert room key card into slot and push ice button switch.
Manitowoc Ice, Inc.
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA 8011233
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 Sheet 1 of 3
Web Site - www.manitowocice.com Rev. 05/31/01