![](/html/e9/e9ea/e9ea95de326538f14e2deec8ac26253bae904e9dca354acab6ebe6d0ac4146c6/bg2.png)
SPECIFICATIONS
Model HK1800 HK1810
Blows per minute
Overall length 315 mm 315 mm
Net weight 3.2 kg 3.2 kg
Safety class
• Due to our continuing programme of research and development, the specifications herein are subject to change
without notice.
3200 min
-1
0 - 3,200 min
/II
• Note: Specifications may differ from country to country.
SYMBOLS
END201-2
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
...................Read instruction manual.
For Model HK1800
For European countries only
Noise and Vibration
The typical A-weighted noise levels are
sound pressure level: 90 dB (A)
sound power level: 101 dB (A)
...................DOUBLE INSULATION
Uncertainty: 3 dB
– Wear ear protection. –
..................Only for EU countries
Do not dispose of electric equipment
together with household waste
material!
In observance of European Directive
2002/96/EC on waste electric and
electronic equipment and its
implementation in accordance with
national law, electric equipment that
have reached the end of their life
must be collected separately and
returned to an environmentally
compatible recycling facility.
Intended use
The tool is intended for chiselling work in concrete, brick,
stone and asphalt as well as for driving and compacting
with appropriate accessories.
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated in accordance with European
Standard and can, therefore, also be used from sockets
without earth wire.
The typical weighted root mean square acceleration
value is 6 m/s
2
.
These values have been obtained according to EN60745.
For Model HK1810
For European countries only
Noise and Vibration
The typical A-weighted noise levels are
sound pressure level: 89 dB (A)
sound power level: 100 dB (A)
Uncertainty: 3 dB
– Wear ear protection. –
The typical weighted root mean square acceleration
value is 8 m/s
2
.
These values have been obtained according to EN60745.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product
is in compliance with the following standards of standardized documents, EN60745, EN55014, EN61000 in
accordance with Council Directives, 89/336/EEC, 98/37/
EC.
Yasuhiko Kanzaki CE 2005
Director
MAKITA INTERNATIONAL EUROPE LTD.
Michigan Drive, Tongwell, Milton Keynes, Bucks MK15
8JD, ENGLAND
Responsible manufacturer:
Makita Corporation Anjo Aichi Japan
-1
2
![](/html/e9/e9ea/e9ea95de326538f14e2deec8ac26253bae904e9dca354acab6ebe6d0ac4146c6/bg3.png)
GENERAL SAFETY RULES GEA001-3
WARNING:
Read all instructions. Failure to follow all instructions listed below may result in
electric shock, fire and/or serious injury. The term “power tool” in all of the
warnings listed below refers to your mains-operated (corded) power tool or batteryoperated (cordless) power tool.
SAVE THESE INSTRUCTIONS
Wor k are a s afety
1. Keep work area clean and well lit. Cluttered and
dark areas invite accidents.
2. Do not operate power tools in explosive atmos-
pheres, such as in the presence of flammable
liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
3. Keep children and bystanders away while oper-
ating a power tool. Distractions can cause you to
lose control.
Electrical safety
4. Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools. Unmodified plugs and matching outlets will
reduce risk of electric shock.
5. Avoid body contact with earthed or grounded
surfaces such as pipes, radiators, ranges and
refrigerators. There is an increased risk of electric
shock if your body is earthed or grounded.
6. Do not expose power tools to rain or wet condi-
tions. Water entering a power tool will increase the
risk of electric shock.
7. Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges or
moving parts. Damaged or entangled cords
increase the risk of electric shock.
8. When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of a
cord suitable for outdoor use reduces the risk of
electric shock.
Personal s afety
9. Stay alert, watch what you are doing and use
common sense when operating a power tool. Do
not use a power tool while you are tired or under
the influence of drugs, alcohol or medication. A
moment of inattention while operating power tools
may result in serious personal injury.
10. Use safety equipment. Always wear eye protec-
tion. Safety equipment such as dust mask, non-skid
safety shoes, hard hat, or hearing protection used
for appropriate conditions will reduce personal injuries.
11. Avoid accidental starting. Ensure the switch is
in the off-position before plugging in. Carrying
power tools with your finger on the switch or plugging in power tools that have the switch on invites
accidents.
12. Remove any adjusting key or wrench before
turning the power tool on. A wrench or a key left
attached to a rotating part of the power tool may
result in personal injury.
13. Do not overreach. Keep proper footing and balance at all times. This enables better control of the
power tool in unexpected situations.
14. Dress properly. Do not wear loose clothing or
jewellery. Keep your hair, clothing, and gloves
away from moving parts. Loose clothes, jewellery
or long hair can be caught in moving parts.
15. If devices are provided for the connection of
dust extraction and collection facilities, ensure
these are connected and properly used. Use of
these devices can reduce dust-related hazards.
Power tool use and care
16. Do not force the power tool. Use the correct
power tool for your application. The correct
power tool will do the job better and safer at the rate
for which it was designed.
17. Do not use the power tool if the switch does not
turn it on and off. Any power tool that cannot be
controlled with the switch is dangerous and must be
repaired.
18. Disconnect the plug from the power source and/
or the battery pack from the power tool before
making any adjustments, changing accessories,
or storing power tools. Such preventive safety
measures reduce the risk of starting the power tool
accidentally.
19. Store idle power tools out of the reach of children and do not allow persons unfamiliar with
the power tool or these instructions to operate
the power tool. Power tools are dangerous in the
hands of untrained users.
3