Specifications
LCOR-DV36IN/RCOR-DV36IN
LCOR-DV36/RCOR-DV36
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH GLASS SIZE
LCOR-DV36
RCOR-DV36
38,000 BTU (NG)
35,500 BTU (LP)
ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING
38"
(965 mm)
38-1/8"
(968 mm)
40-1/2"
(1029 mm)
40"
(1016 mm)
40-1/2"
(1029 mm)
Ø
40"
(1016 mm)
8" [203]
24-1/2"
(622 mm)
LEFT/RIGHT
LEFT/RIGHT
CORNER
CORNER
Direct Vent Gas Fireplace
Direct Vent Gas Fireplace
24"
(610 mm)
33" x 21-5/8"
[838 x 549]
24-1/2"
[622]
12"
[305]
TOP VIEW
TOP VIEW
9-1/2"
[241]
38"
[965]
34-5/8"
[880]
1"
[25]
33" [838]
40-1/2" [1029]
FRONT VIEW
FRONT VIEW
21-5/8"
[549]
33-1/2"
2-1/8"
[54]
[851]
Ø 8" [203]
Electrical
Access
Gas Line
Access
27"
[686]
VIEWABLE END
VIEWABLE END
4-1/8"
[105]
4-1/4"
[108]
NON-VIEWABLE END
NON-VIEWABLE END
1-1/2"
[38]
Specifications
LCOR-DV36/RCOR-DV36
MINIMUM FIREPLACE CLEARANCES
AREA
CLEARANCE TO CEILING 31-5/8
COMBUSTIBLE/NON-COMBUSTIBLE FLOOR 0
END OF APPLIANCE 0.5
SIDES OF APPLIANCE 36
TO COMBUSTIBLES
FIREPLACE LOCATIONS
LCOR
36"
[914]
36"
[914]
36"
[914]
WALL PENETRATION
(in inches)
RCOR
[914]
36"
FRAMING DIMENSIONS
**DVP Pipe: 10" [254]
SLP Pipe: 8-5/8" [219]
**
24"
[610]*
38-1/8"
[968]
40" [1016]
* Adjust framing dimensions
for interior sheathing, such
as sheetrock
CLEARANCES TO COMBUSTIBLES
31"
[787]
1/2" [13]
36"
[914]
36"
[914]
1/2" [13]
*43-3/4"
10"
10"
*28"
12"
12"
42-3/4"
27"
* Note: Shows center of vent
framing hole for top/rear venting.
Center of hole is 1" above the
center of the horizontal vent pipe.
MANTEL LEG/WALL PROJECTIONS
TOP VIEW
Fireplace
Opening
2-3/4"
minimum
1" maximum
3-1/4" min.
Note:
Clearance from opening to perpendicular wall.
1/2" minimum
Unlimited
0"
MANTEL PROJECTIONS
4
3
1
5
MAX.
To Non-Combustible Mantel
Measurements from top edge of opening
PRODUCT LISTING CODES
US ANSI Z21.88-2016
CAN CSA 2.33-2016
0"
MAX.
18
12
11
10
9
8
7
6
5
10
4
16
15
14
13
12
11
To Combustible Mantel
TO CEILING
12
10
9
8
7
6
8
7
6
TO CEILIN G
31
25
19
18
17
MIN.
31
MIN.
12
10
9
Product information provided is not
complete and is subject to change
without notice. Product installation
must adhere strictly to instructions
accompanying product to avoid risk
of fire and potential injury.
Majestic — A Brand of Hearth & Home Technologies
7571 215th Street West | Lakeville, MN 55044
877-486-9123 | majesticproducts.com
MAJ/PEARL_LCOR-DV36IN/RCOR-DV36IN_1118