Specifications
15-7/8" [403]
6-5/8" [168]
Ø
30-3/4" [781]
15-3/8" [391]
8-13/16"
[224]
16-5/16" [414]
1/2" [13]
32-1/16" [814]
33-9/16"
[853]
41" [1041]
36-1/8" [918]
1" [25]
37-5/8"
[956]
21-1/2"
[546]
3-9/16"
[90]
ELECTRICAL
ACCESS
6-7/8"
[175]
26-7/8"
[683]
39-15/16"
[1014]
37-7/8"
[962]
8" [203]
Ø
6-5/8" [168]
Ø
30-3/4" [781]
8-13/16"
[224]
16-5/16" [414]
1/2" [13]
3-9/16"
[90]
ELECTRICAL
ACCESS
6-7/8"
[175]
26-7/8"
[683]
39-15/16"
[1014]
37-7/8"
[962]
8" [203]
Ø
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
QUARTZ 36
Direct Vent Gas Fireplace
design layout decision.
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH GLASS SIZE
QUARTZ36
Actual Framing Actual Framing Actual Framing Actual Framing
37-7/8"
[962]
38-1/4"
[972]
41"
[1041]
42"
[1067]
30-3/4"
[781]
42"
[1067]
16-5/16"
[415]
16-1/4"
[413]
TOP VIEW
30-3/4" [781]
15-3/8" [391]
1/2" [13]
32-1/16" x 21-1/12"
[814 X 546]
QUARTZ36
15-7/8" [403]
6-5/8" [168]
Ø
FRONT VIEW
32-1/16" [814]
33-9/16"
[853]
36-1/8" [918]
HEAT-ZONE® ACCESS
Ø
5" [127]
LEFT SIDE RIGHT SIDE
GAS LINE ACCESS
9-1/8"
[232]
6"
[152]
14" [356]
2-3/16" [56]
41" [1041]
3-9/16"
[90]
8-13/16"
[224]
21-1/2"
[546]
1" [25]
6-7/8"
[175]
16-5/16" [414]
37-5/8"
[956]
8" [203]
Ø
39-15/16"
[1014]
37-7/8"
[962]
26-7/8"
[683]
ELECTRICAL
ACCESS
Specifications
5
6
7
8
9
10
3
4
5
12
11
10
9
8
7
6
TOP OF HOOD
4
12
13
11
32
CEILING
QUARTZ36
APPLIANCE LOCATION
A
K
E
A
I
C
J
I
L
D
B
H
G
F
A B C E F G H I J K L
45-1/2"
42"
64-3/8"
1/2"
45-1/2"
64-3/8"
16-1/4"
48-1/2"
68-3/4"
[1156]
[1067]
[1635]
[13]
[1156]
[1635]
[413]
[1232]
[1746]
16-5/8"
[422]
WALL PENETRATION
40"
26-7/8"
[1016]
10"
10"
[683]
7-1/2"
[191]
FRAMING DIMENSIONS
B
D
F
A
Rough Opening (Width)
DVP pipe SLP pipe DVP pipe SLP pipe
10"
[254]
8-5/8"
[219]
B
Rough Opening
(Height)
38-1/4"
[972]
CLEARANCES TO COMBUSTIBLES
0"
A
C
C
Rough Opening (Depth)
16-1/4"
[413]
Measure from top of unit
opening or from top of hood
16-1/4"
[413]
32"
[813]
1/2" [13]
D
Rough Opening
(Width)
42"
[1067]
41"
[1041]*
10"
27-7/8"
[708]*
12"
*Shows center of vent hole for top
or rear venting. Center of hole is 1"
above the center of the horizontal
vent pipe.
MANTEL LEG/WALL PROJECTIONS
1/2"
minimum
3ft. maximum
Top View
Wall Projection
(acceptable on one side of opening)
Top View
2-7/8"
minimum
Mantel Leg Projection
(acceptable on both sides of opening)
Lakeville, MN Phone: (800) 927-6841
Web: www.majesticproducts.com
5-3/8"
minimum
3 IN.
minimum
Unlimited
36" [915]
0"
1/2" [13]
MANTEL PROJECTIONS
PRODUCT LISTING CODES
US ANSI Z21.88-2014
CAN CSA 2.33-2014
Additional information can be found online at www.majesticproducts.com
Product information provided is not
complete and is subject to change
without notice. Product installation
must adhere strictly to instructions
accompanying product to avoid risk of
fire and potential injury.