Majestic PVLPSLP Installation Manual

PVLP-SLP
Power Vent Low Prole
- Installation Instructions -
DO NOT DISCARD THIS MANUAL
1
• Important operating and maintenance instructions included.
Introduction
• Read, understand and follow these instructions for safe installation and operation.
Table of Contents
1 Introduction
A. Components and Service Parts List ..................2
B. Installation of PVLP-SLP ..........................3
2 Vent Information and Diagrams
A. Installation of Vent Pipe ...........................4
B. Vent/Pipe Regulations ............................ 4
C. Venting Length - Model Categories and Length
Requirements by Termination Type .................9
3 Framing and Clearances
A. Framing and Clearances ..........................10
B. Installing Vent Cap .............................. 12
NOTICE
DO NOT
DISCARD
• Leave this manual with party responsible for use and operation.
Installation of the PVLP-SLP may be done by a quali­ed service technician only. Installation MUST com­ply with local, regional, state and national codes and regulations.
IMPORTANT: Failure to read and follow these instruc-
tions may create a possible hazard and will void the re­place warranty.
These instructions must remain with the equipment.
CAUTION! Risk of Cuts or Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp.
4 Electrical Information
A. Wiring the Appliance for the PVLP-SLP with IntelliFire Plus
Controls ......................................17
B. Wiring the Appliance for the PVLP-SLP with IntelliFire Touch
(IFT) Controls ..................................22
C. Pairing the IFT-RC400 to the Electronic Control Electronic
Control module (IFT-ECM) ........................ 26
5 Operating Instructions
A. Installation Inspection ............................27
B. Setting the PVLP-SLP Bafe Adjustment .............27
C. Operating Instructions ............................27
D. Maintenance ...................................28
E. Replace Blower/Pressure Switch ................... 29
F. PVLP-SLP Troubleshooting ........................30
G. IFT-Controls and PVI-SLP Power Vent Troubleshooting . .31
H. Addendum: Signature Command Fireplaces. . . . . . . . . . . 32
1
Hearth & Home Technologies • Power Vent Low Prole (PVLP-SLP) Instructions • 4052-900 Rev. L • 08/10/17
INTRODUCTION
The Power Vent Low Prole (PVLP-SLP) is certied for use as a horizontal termination cap only on replaces manufactured by Hearth & Home Technologies with IPI (in­termittent pilot ignition) gas controls. Fireplaces equipped with millivolt type gas controls CANNOT use this product.
BLOWER ASSEMBLY
4052-796
VACUUM SWITCH
4052-840
Note: PVLP-SLP requires special control system congurations:
For IntelliFire and IntelliFire Plus models, a RC100, RC200 or RC300 and PV-IPI-CK control system is required for installation (except on PRIMO models). The PV-IPI-CK is sold separately.
For IntelliFire Touch models, an IFT-ACM and IFT- RC400 is required for installation. The IFT-ACM and IFT-RC400 may need to be purchased separately if the appliance is not already equipped with IFT.
The battery-backup feature cannot be used with models congured with the PVLP-SLP.
The wired wall switch feature cannot be used with models congured with the PVLP-SLP.
An appliance with PVLP-SLP installed cannot be operated with battery-backup or a wired wall switch.
Note: The battery back-up and wired wall switch feature of any IPI system are removed when the PVLP-SLP power vent is installed. The replace may no longer be operated with battery back-up and/or a wired wall switch.
IMPORTANT OPERATIONAL NOTE: When the control being used to run the replace is activated, a 120 seconds delay will occur before pilot ignition will begin. This is to allow a pre-purge by the PVLP-SLP. If, after 135 seconds, the pilot and burner do not light, refer to the Troubleshooting section of this instruction for further direction. There will also be a 20-minute post-purge in which the PVLP-SLP will continue to run after appliance is turned off.
NOTICE: The blower motors present in this power vent will generate sound during operation. The effects of the increased sound level can be minimized with careful plan­ning during installation of the system.
The PVLP-SLP operates on 120VAC, 60Hz electrical service which is supplied at the replace junction box.
A. Components and Service Parts List
Service Parts List
Replacement parts can be obtained from your dealer. Re­pair of the Power Vent should only be done by a qualied service technician.
Required Wire Harness
Lengths Available Part Number
10 ft. PV Wire Harness PVI-WH10
20 ft. PV Wire Harness PVI-WH20
40 ft. PV Wire Harness PVI-WH40
60 ft. PV Wire Harness PVI-WH60
80 ft. PV Wire Harness PVI-WH80
100 ft. PV Wire Harness PVI-WH100
NOTE: Wire Harness connecting PVLP-SLP to appliance sold separately. The length of wire harness needed varies by installation. For all appliances equipped with IntelliFire™ or IntelliFire™ Plus ignition, other than the PRIMO, PV-IPI-CK con­version kit and one of the following; RC100, RC200 or RC300 are required. This kit includes all components to install the PVLP-SLP to IntelliFire™ or IntelliFire™ Plus appliances. For appliances equipped with IntelliFire™ Touch (IFT) controls, an IFT-RC400 remote and an IFT-ACM are required on the appliance.
Figure 1.1 Service Parts
2
Hearth & Home Technologies • Power Vent Low Prole (PVLP-SLP) Instructions • 4052-900 Rev. L • 08/10/17
B. Installation of PVLP-SLP
1. INSTALLATION PRECAUTIONS
a. This device must be installed by a qualied installer
in accordance with these instructions.
b. Safety inspection of the venting system should
be performed before and after installation of this power vent. Consult local code ofcials and follow applicable installation codes.
c. DO NOT INSTALL DAMAGED EQUIPMENT OR
VENT COMPONENTS.
d. Disconnect electrical power supply before making
wiring connections.
e. Venting of more than one appliance in a common
vent system is prohibited.
f. Clearances between the vent pipe and combustible
materials must be maintained at 1-1/2 inches top, 1 inch sides and bottom.
g. All outer pipe joints must be sealed with silicone
(with a minimum of 300° F continuous exposure rating). See Section 2.A.
CAUTION! Failure to install, operate, and maintain the power venting system in accordance with manufacturer's instructions will result in conditions which may produce bodily injury and/or property damage.
2. INSTALLATION GUIDELINES
a. The exit termination of mechanical draft systems shall
not be less than seven feet above grade when located adjacent to public walkways.
b. A mechanical drafting venting system shall terminate at
least three feet above any forced air inlet located within 10 feet.
c. A PVLP-HS heat shield is available and sold separately
if the PVLP-SLP is installed in an accessible area.
d. If the PVLP-SLP will be installed in a location
where the exhaust housing assembly needs to be removed for service or maintenance, the pipe must be installed to allow for a minimum of 18" of pipe to be removed at the time of service. This will allow adequate space to remove the exhaust housing assembly.
3
Hearth & Home Technologies • Power Vent Low Prole (PVLP-SLP) Instructions • 4052-900 Rev. L • 08/10/17
2
Vent Information and Diagrams
A. Installation of Vent Pipe
For information on standard procedures for venting the
appliance, refer to the "Vent Information and Diagrams"
section of the appliance installation manual.
For the allowable pipe lengths and elbow combinations for an appliance utilizing the PVLP-SLP, consult the Power Vent diagrams in the Vent Information and Diagrams sec­tion of the appliance installation manual. The PVLP-SLP uses SLP pipe (6-5/8 inch) connections.
In certain cases, a pipe adapter may be used in the vent run. The DVP-2SL adapts from 5 in. / 8 in. DVP series starting collars to 4 in. / 6-5/8 in. SLP series vent pipe. A DVP-SLP24 may also be used to transition from a DVP to SLP pipe when using this cap.
Either SLP or DVP venting may be used throughout the vent run except on certain models that require DVP pipe. See Table 2.1. Refer to Section 2.B for more information regarding venting regulations.
All outer pipe joints must be sealed with silicone (with a minimum of 300ºF continuous exposure rating), includ­ing the slip section that connects directly to the horizontal termination cap.
• Apply a bead of silicone sealant inside the female outer
pipe joint prior to joining sections. See Figure 2.1.
• Only outer pipes need to be sealed. All unit collar, pipe,
slip section, elbow and cap outer ues shall be sealed in this manner, unless otherwise stated.
B. Vent/Pipe Regulations
WARNING! Risk of Fire!
Maintain minimum pipe length requirement between appliance and PVLP-SLP on all models. Combustible materials surrounding pipe may overheat.
1. A minimum length of venting is required between the appliance and the PVLP-SLP. This minimum length requirement varies for the specic appliance. Refer to Table 2.1. for requirements for specic models. Once the minimum length requirement is met, the PVLP-SLP may be installed at any location within the vent run conguration.
2. For every 1 ft. of vertical drop the total allowable length must be reduced by 2 ft.
Note: See Table 2.1 for model specic vent requirements.
Figure 2.1 Silicone Sealant
4
Hearth & Home Technologies • Power Vent Low Prole (PVLP-SLP) Instructions • 4052-900 Rev. L • 08/10/17
B. Vent/Pipe Regulations (continued)
WARNING! Risk of Fire!
• A minimum length run of initial vent pipe is required between the appliance and the inlet of the PVLP-SLP on some appliance models.
Some models require DVP Series pipe for the initial minimum vent section directly off the appliance.
*If using the PVLP-SLP with a Majestic replace refer to addendum on page 28.
MODEL MINIMUM VENTING BETWEEN APPLIANCE AND PVLP-SLP
6000C, 6000CL, 6000CLX, 8000C, 8000CL, 8000CLX 6000BEC
6000CMOD, 8000CMOD
CD4236, CD4842
CNXT4236, CNXT4842
DBDV36I, DBDV42I, DBDV36PLATI, DBDV42PLATI
ECLIPSE-32, ECLIPSE-36
EVEREST
GDST3831, GDST4336, GDCR4136, GDCL4136
RCOR-DV36IN, LCOR-DV36IN
ION-S7, ION-H7
NDV3630, NDV3933, NDV4236, NDV4842
NEVO3630, NEVO4236
PEARL36PRIN, PEARL36STIN
NNXT3933, NNXT4236
ST-36TR. ST-36TR, ST-36TRB, PIERI-36TR, PIER­36TRB, LCOR-36TRB, RCOR-36TRB
PRIMO48, PRIMO60, PRIMO72, PRIMO48ST, PRIMO60ST, PRIMO72ST
QUARTZ32I, QUARTZ36I
REVO-S21, REVO-H31
SLR32, RAVE3012I
SLR, RAVE4013I
SL-350TRS, SL-550TRS, SL-750STRS
SL-550TR, SL-750TR, SL-950TR
SL-550METRO
SL-550F, SL-750F
SL-5, SL-7, SL-9
SL-3X, SL-5X, SL-7X, SL-9X, SL-3X-IFT, SL-5X-IFT, SL-7X-IFT, SL-9X-IFT
ST-550T, ST-550TM
MODEL MINIMUM VENTING BETWEEN APPLIANCE AND PVLP-SLP
ALL ESC-42ST
ALL HEIR36, HEIR42, HEIR50
ALL LUX36, LUX42
ALL TRUE-36, TRUE-42, TRUE-50 CERONA-36, CERONA-42
MEZZO36, MEZZO36ST, MEZZO48, MEZZO48ST MEZZO60, MEZZO60ST, MEZZO72, MEZZO72ST
CRAVE4836, CRAVE4836ST, CRAVE6048, CRAVE6048ST, CRAVE7260, CRAVE7260ST, CRAVE8472, CRAVE8472ST
No minimum vertical venting required for rear vent appliances. Must
have a 90 degree elbow for top vent appliances.
Minimum two feet straight vertical DVP pipe directly off appliance followed by 90 degree elbow and DVP-2SL or DVP-SLP24 adapter.
Table 2.1
5
ECHEL36IN, ECEL36STIN, ECHEL48IN, ECHEL48STIN, ECHEL60IN, ECHEL72IN
MARQ36IN, MARQ42IN, MARQ42STIN
Hearth & Home Technologies • Power Vent Low Prole (PVLP-SLP) Instructions • 4052-900 Rev. L • 08/10/17
MAXIMUM VERTICAL
DROP
MAXIMUM VERTICAL
DROP
FROM
APPLIANCE
ADAPTER KITS
PART NUMBER PART DESCRIPTION
DVP-SLP24 Adapts from 5 in./ 8 in. DVP-series starting collars to 4 in./ 6-5/8 SLP-series vent pipe.
DVP-2SL Adapts from 5 in./ 8 in. DVP-series starting collars to 4 in./ 6-5/8 SLP-series vent pipe.
DIRECT VENT WITH 4 in./ 6-5/8 in. DIAMETER SLP PIPE
MAX. ELBOWS
MAX. TOTAL VENT
(45° & 90°)
12-45° or 6-90°
*only allowed on certain
See chart in Section 2.C
DIRECT VENT WITH 5 in. / 8 in. DIAMETER DVP PIPE
MAX. ELBOWS
MAX. TOTAL VENT
(45° & 90°)
12-45° or 6-90°
*only allowed on certain
See chart in Section 2.C
Note: For every 1 ft. of vertical drop the total allowable length must be reduced by 2 ft.
RUN (FT.)
100’
models
RUN (FT.)
100’
models
MAX. VERT.
DROP (FT.)
12’
MAX. VERT.
DROP (FT.)
12’
Note: See the PRIMO install manual (2310-970) for allowed vent congurations for the following SKUs: PRIMO48 PRIMO60 PRIMO72 PRIMO48ST PRIMO60ST PRIMO72ST
NOTE: Maximum total vent run= Total vertical vent run + Total horizontal vent run
NOTICE: If a a pipe conguration includes
a vertical component that goes downward, a vertical component going back upward is not allowed.
6
Hearth & Home Technologies • Power Vent Low Prole (PVLP-SLP) Instructions • 4052-900 Rev. L • 08/10/17
H
1
H
2
V
2
V
1
A DVP-2SL or DVP-SLP24 is required in any position after the first 90 degree elbow on certain models. See Table 2.1.
Top Vent - Horizontal Termination
Note: For every 1 ft. of vertical drop the total allowable length must be reduced by 2 ft.
WARNING! Risk of Fire! Minimum 2 ft. straight vertical DVP pipe directly off appliance followed by 90 degree elbow and DVP-2SL adapter on these models:
ESCAPE-42DV, ESCAPE-36DV, ESC-42ST, HEIR36, HEIR42, HEIR50, LUX36, LUX42, TRUE-36, TRUE-42, TRUE-50, CERONA-36, CERONA-42, MEZZO36, MEZZO36ST, MEZZO48, MEZZO48ST, CRAVE4836, CRAV­E4836ST, CRAVE6048, CRAVE6048ST, CRAVE7260, CRAVE7260ST, CRAVE8472, CRAVE8472ST, MEZZO60, MEZZO60ST, MEZZO72, MEZZO72ST, MARQ36IN, MARQ42IN, MARQ42STIN, ECHEL36IN, ECEL36STIN, ECHEL48IN, ECHEL48STIN, ECHEL60IN, ECHEL72IN
Combustibles surrounding pipe may overheat.
Minimum Vent Run Maximum Vent Run
A minimum of 2 ft. of vertical piping is required between the appliance and the PVLP-SLP with certain appliance mod­els. See Table 2.1.
Figure 2.2 Horizontal PVLP Orientation
See Chart in Section 2.C: "Venting Length - Model Categories and Length Requirements by Termination Type."
7
Hearth & Home Technologies • Power Vent Low Prole (PVLP-SLP) Instructions • 4052-900 Rev. L • 08/10/17
Top Vent - Horizontal Termination con't.
Note: For every 1 ft. of vertical drop the total allowable length must be reduced by 2 ft.
NOTICE: If pipe configuration includes a vertical component that goes downward, a vertical component going back upward is not allowed.
H
1
V
1
V
2
H
2
A DVP-2SL or DVP-SLP24 is required in any position after the first 90 degree elbow on certain models. See Table 2.1.
WARNING! Risk of Fire! Minimum 2 ft. straight vertical DVP pipe directly off appliance followed by 90 degree elbow and DVP-2SL adapter on these models:
ESCAPE-42DV, ESCAPE-36DV, ESC-42ST, HEIR36, HEIR42, HEIR50, LUX36, LUX42, TRUE-36, TRUE-42, TRUE­50, CERONA-36, CERONA-42, MEZZO36, MEZZO36ST, MEZZO48, MEZZO48ST, CRAVE4836, CRAVE4836ST, CRAVE6048, CRAVE6048ST, CRAVE7260, CRAVE7260ST, CRAVE8472, CRAVE8472ST, MEZZO60, MEZZO60ST, MEZZO72, MEZZO72ST, MARQ36IN, MARQ42IN, MARQ42STIN, ECHEL36IN, ECEL36STIN, ECHEL48IN, ECH­EL48STIN, ECHEL60IN, ECHEL72IN
Combustibles surrounding pipe may overheat.
Minimum Vent Run Maximum Vent Run
A minimum of 2 ft. of vertical piping is required between the appliance and the PVLP-SLP with certain appliance mod­els. See Table 2.1.
Figure 2.3 Horizontal PVLP Orientation
8
Hearth & Home Technologies • Power Vent Low Prole (PVLP-SLP) Instructions • 4052-900 Rev. L • 08/10/17
See Chart in Section 2.C: "Venting Length - Model Categories and Length Requirements by Termination Type."
C. Venting Length - Model Categories and Length Requirements by Termination Type
The Model Category (0,1, 2 or 3) in Table 2.2 corresponds with the number in the shaded area of the Allowable Vent Length Chart In Table 2.3.
HEAT & GLO HEATILATOR MAJESTIC MAJESTIC HHT
Category 0Category
REVO-S21 ST-550T
REVO-H31 S T-
0 &1
550TM
SLR32 6000C, 6000CL, 6000CLX,
Category 0, 1 & 2
SL-550TR, SL-750TR, SL-950TR
SL-350TRS, SL-550TRS, SL-750TRS
6000BEC
8000C, 8000CL, 8000CLX
6000CMOD, 8000CMOD ESCAPE-42DV DV3732
SL-550METRO, SL-550­BE-M
ST-36TR,ST-36TRB,PIER­36TR, PIER-36TRB, LCOR­36TRB,RCOR-36TRB
MEZZO60, MEZZO60ST MEZZO72, MEZZO72ST
MEZZO36, MEZZO36ST, MEZZO48, MEZZO48ST
SL-550F, SL-750F
EVEREST ION-H7
SL-5, SL-7, SL-9 ECLIPSE-36
SL-3X, SL-5X, SL-7X, SL-9X
SL-3X-IFT, SL-5X-IFT, SL­7X-IFT, SL-9X-IFT
Category 0,1,
2 & 3
SLR-B, SLR-C ION-H7 RAVE3012I
RED40, RED40ST
ALL ESC-42ST
ESCAPE-36DV
ALL TRUE-36
ALL TRUE-42
ALL TRUE-50
ALL
LUX36, LUX42
CERONA-36 CERONA-42
Category 0Category
ION-S7 CD4236,
0, 1
Category 0,
1 & 2
NDV3630, NDV3933, NDV4236, NDV4842
CD4842
CNXT4236, CNXT4842
NEVO3630, NEVO4236
GDST3831, GDST4336, GDFL4136, GDCR4136, GDCL4136
CRAVE4836, CRAVE4836ST CRAVE6048, CRAVE6048ST
CRAVE7260, CRAVE7260ST, CRAVE8472, CRAVE8472ST
NNXT3933 NNXT4236
Category 0,
1, 2 & 3
RAVE4013i DBDV36I,
ALL HEIR36, ALL HEIR42, ALL HEIR50
Category 0,
1 & 2
DBDV42I, DBDV36PLATI, DBDV42PLATI
QUARTZ32I, QUARTZ36I
PEARL36PRIN PEARL36STIN
ECHEL36IN, ECHEL36STIN ECHEL48IN, ECHEL48STIN
ECHEL60IN, ECHEL72IN
Category 0,
1, 2 & 3
MARQ36IN MARQ42IN MARQ42STIN
Category 0,1
& 2
RCOR-DV36IN LCOR-DV36IN
Table 2.2 Models
Note: The REVO-V12 and ION-V7 is not approved for use with the PVLP-SLP.
Note: See the PRIMO install manual (2310-970) for allowed vent congurations for the following SKUs: PRIMO48,
PRIMO60, PRIMO72, PRIMO48ST, PRIMO60ST, PRIMO72ST.
Horizontal Termination
Total Venting Length (Feet) Includes both horizontal and vertical section of pipe
# of Elbows 10 20 30 40 50 60 70 80 90 100 110 120 130 140
1 0 0 0 0 1 1 1 1 2 3
2 0 0 0 0 1 1 1 2 3
3 0 0 0 0 1 1 1 2
4 0 0 0 1 1 1 2 3
5 0 0 0 1 1 1 2
6 0 0 1 1 1 2 3
7 0 0 1 1 1 2 3
8 0 1 1 1 1 2
9 0 1 1 1 1 2
10 1 1 1 1 2 3
11 1 1 1 1 2
12 1 1 1 1 2
Table 2.3 Allowable Vent Runs - Horizontal Termination
These congurations are not allowed.
9
Hearth & Home Technologies • Power Vent Low Prole (PVLP-SLP) Instructions • 4052-900 Rev. L • 08/10/17
3
14 in.
[356mm]
15-1/2 in. [394mm]
[292mm]
11-1/2 in.
8 in.
[203mm]
[112mm]
4-3/8 in.
5-1/4 in.
4-3/4 in.
2-1/4in.
10 in.
[254mm]
[135mm]
[57mm]
2-1/4in.
[57mm]
[121mm]
[241mm]
9-1/2 in.
12-1/2 in. [318mm]
[159mm]
6-1/4 in.
1-1/2 in. [38mm]
Front View Without Cover
Front View With Cover Side View
Back View
Top view
10 IN.
13 IN.
Framing and Clearances
A. Framing and Clearances
Chassis Dimensions
The dimensions are measured as shown in Figure 3.1.
Figure 3.1 Dimensions
Framing Dimensions
1. Construct a framework as shown in Figure 3.2.
Framework material should be the same dimensions as the material used for the wall framing. The dimensions of the box must be 10 inches high by 13 inches wide.
2. Cut a 10 inch high by 13 inch wide opening into the
exterior of the structure. Stay inside of the newly installed framing as shown in Figure 3.2.
Figure 3.2
10
Hearth & Home Technologies • Power Vent Low Prole (PVLP-SLP) Instructions • 4052-900 Rev. L • 08/10/17