Magellan Paradox 2WPGM Instructions Manual

The 2WPGM is a two-way wireless PGM, which also provides one zone input. After assigning the PGM module to a system, the PGM can be programmed to activate and deactivate, as detailed in the system’s programming guide.
Location and Mounting
The 2WPGM must be installed within 35 m (115 ft.) of the control panel. Before you mount the 2WPGM, perform the signal strength tests to ensure optimal performance of the unit.
Do not cut, bend, or alter the antenna.
Avoid mounting the PGM module near or on metal, as this may affect transmission.
Powering the Unit
The unit requires either AC or DC power input. For wire connections, see Figure 1.
AC: 6 Vac (500 mA) to 16.5 Vac (200 mA) DC: 5 Vdc (500 mA) to 24 Vdc (200 mA)
The external power supply used with this module must be of an Approved/Certified type, acceptable to the authorities where the module is installed and used.
Enrollment and Testing
Jumper 2 (JP2) is used for enrolling (Learn mode) and for testing signal strength.
Learn Mode: Remove and re-install JP2.
Signal Strength: Perform a transmission by
temporarily removing and re-installing JP2, or by opening the zone that is connected to the PGM. To interpret the RSSI LED, see the LED Indicators table.
To test the signal strength of the 2WPGM at the control panel, see the control panel’s programming guide.
Normal Operation: JP2 must be
CLOSED for
normal operation.
Zone Setting
ZONE Jumper determines the input setting of the zone.
ZONE
CLOSED = Normally Closed (N.C.) zone
(default)
ZONE
OPEN = Normally Open (N.O.)
zone
Do not use EOL resistors with universal/zone
inputs.
Figure 1
Instructions
Two-way Wireless PGM
2WPGM (433/868MHz)
V1.1
Printed in Canada 10/2015 www.paradox.com 2WPGM-EI05
ZONE
JP2
AC/DC Power
PGM Output
Door Contact
Antenna
Relay
LED Indicator
LED Indicator
Technical Specifications
LED Indicators
Warranty
The Limited Warranty Statement can be found on the website www.paradox.com/terms.
Patents
Your use of the Paradox product signifies your acceptance of these terms and conditions.
One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending patents may apply. Canadian and international patents may also apply.
© 2015 Paradox Security Systems (Bahamas) Ltd. All rights reserved. Specifications may change without prior notice.
Specification Description
Power Input AC: 6 Vac (500 mA) to 16.5
Vac (200 mA) DC: 5 Vdc (500 mA) to 24 Vdc (200 mA)
RF Frequency 433 MHz, 868 MHz
Current Consumption
Relay ON: 45-160 mA Relay OFF: 6-20 mA
PGM 1 N.O./N.C. 5A, 28V relay
Relay’s Maximum Voltage
60 Vdc/28 Vac
Operating Temperature
0°C to 50°C (32°F to 122°F)
Range 35 m (115 ft.) with MG6250
70 m (230 ft.) with MG5000 / MG5050 / RTX3
Compatibility • MG6250, MG5000 and
MG5050
• SP5500, SP6000, SP7000 and SP65 (RTX3 is required)
• EVO192 and EVOHD (RTX3 is required)
Dimensions 12.5 cm x 4.6 cm x 2.5 cm
(4.9 in. x 1.8 in. x 1.0 in.)
Certification For updated information, visit
www.paradox.com
LED Description
RX Receiving information
TX Sending information
RSSI
Indicates signal strength
Flash twice Strong signal Flash once Weak signal No flash No signal
Relay Indicates that the relay is ON