The MR6T (Black) and MR6WT (White) are a
compact full-range speaker system designed
for constant-voltage systems. The single 6.3"
dual-cone woofer achieves wide bandwidth
and natural, smooth sound reproduction,
ideal for use in business music systems and
indoor/outdoor background music applications.
Connections are made to recessed, colorcoded spring-loaded terminals.
The enclosure is a vented design,
constructed of high-density polystyrene,
with four M6 threaded inserts for use with
mounting hardware, and includes a protective
perforated steel grille.
Safety First!
Before connecting and using the equipment,
please read this Quick-Start Guide carefully
and keep it for future reference.
WARNINGWARNING
WARNING! This equipment has been
WARNINGWARNING
designed to be installed by qualified
professionals only! There are many factors to
be considered when installing professional
sound reinforcement systems, including
mechanical and electrical considerations, as
well as acoustic coverage and performance.
Mackie Industrial strongly recommends that
this equipment be installed only by a
professional sound installer or contractor.
1.1.
Attention to the precautionsAttention to the precautions
1.
Attention to the precautions – Always
1.1.
Attention to the precautionsAttention to the precautions
follow the precautions provided on this
Mackie Industrial product and in the
instruction manual.
2.2.
Water and humidityWater and humidity
2.
Water and humidity – Do not use this
2.2.
Water and humidityWater and humidity
Mackie Industrial product near water; for
example, in the vicinity of a bath tub or sink,
in a damp cellar, near a swimming pool, etc..
Quick-Start Guide
3.3.
Foreign bodies and liquidsForeign bodies and liquids
3.
Foreign bodies and liquids – Be careful not
3.3.
Foreign bodies and liquidsForeign bodies and liquids
to allow any foreign bodies or liquids to get
into this Mackie Industrial product.
4.4.
Technical serviceTechnical service
4.
Technical service – The user should never
4.4.
Technical serviceTechnical service
attempt to make any repairs on this Mackie
Industrial product unless otherwise indicated
in the instruction manual. All repairs should
be made by qualified service technicians.
5.5.
Installation Installation
5.
Installation – Do not install this Mackie
5.5.
Installation Installation
Industrial product in any way that is not
provided for in the instruction manual.
6.6.
Stacking multiple units Stacking multiple units
6.
Stacking multiple units – To prevent the
6.6.
Stacking multiple units Stacking multiple units
danger of falling equipment, never stack
multiple units of this Mackie Industrial
product unless this possibility is expressly
indicated in the instructions.
7.7.
Respect the safety standardsRespect the safety standards
7.
Respect the safety standards – The entire
7.7.
Respect the safety standardsRespect the safety standards
sound system must be designed in
compliance with the current standards and
laws regarding electrical systems.
8.8.
SpecificationsSpecifications
8.
Specifications – When installing and using
8.8.
SpecificationsSpecifications
this Mackie Industrial product, keep in mind
the technical specifications indicated in the
dedicated section of the manual.
9.9.
AccessoriesAccessories
9.
Accessories – Install and use this Mackie
9.9.
AccessoriesAccessories
Industrial product only with the accessories
specified by the manufacturer or supplied
with the product.
Hearing loss Hearing loss
Hearing loss - Exposure to high sound levels
Hearing loss Hearing loss
can cause permanent hearing loss. The sound
pressure level which leads to hearing loss
varies considerably from one person to
another, and depends on the duration of
exposure. The U.S. Government’s
Occupational Safety and Healt Administration
(OSHA) has established the maximum sound
pressure levels that can be with stood without
causing damage, which are shown in the table
below. According to the OSHA regulations,
any exposure over the maximum limits
indicated in the table can reduce the hearing
capacity of a person. To prevent potentially
dangerous exposure to high sound pressure
levels, anyone subjected to such levels must
use suitable protection. When a Mackie
Industrial product capable of producing high
sound levels is being used, it is therefore
necessary to wear ear plugs or protective
earphones when the limits shown in the table
are exceeded.
Consult the specifications provided in the
instruction manual to know the maximum
sound pressure (SPL) the speaker is capable
of producing.
AND REGISTERED TRADEMARKS OF MACKIE DESIGN INC.: "MACKIE",
"MACKIE INDUSTRIAL", & THE "RUNNING MAN" FIGURE
50W
BYPASS
SERIAL NUMBER
50V
25V
70V
0
100V
4
INPUT
70V Connection
MONITOR 6T
25W
10W
0
50W
–+
MONITOR 6T
25W
10W
0
50V
25V
BYPASS
70V
0
100V
4
50W
+–+–
50V
25V
70V
0
100V
BYPASS
4
OUTPUTS
LR
+ – + –
MONITOR 6T
25W
10W
0
50W
BYPASS
4
POWER AMPLIFIER
50V
25V
70V
0
100V
OUTPUTS
25V 50V 70V 100V GND
POWER AMPLIFIER
MONITOR 6T
BYPASS
50V
25V
70V
0
100V
4
25W
10W
0
50W
–+
4 Ohm Stereo Connection
3
Rear Panel Features
and Controls
1. This rotary control selects the power tap
for the internal constant voltage
transformer. Choices are 1W, 2.5W, 5W,
10W, 20W, and BYPASS (used for 4Ω
operation).
2. This rotary control selects the constant
voltage distributed system in which the
speaker is used. Choices are BYPASS
(used for 4Ω operation), 0(Off), 25V, 50V,
70V, and 100V.
Note: Use a slot-head screwdriver to
adjust the rotary controls.
3. Use these spring-loaded terminals to
connect the speaker wiring.
MONITOR 6T
Connections
The spring-loaded speaker terminals are
designed to accept bare wire, up to a
maximum of 18 gauge. Strip 1/4" of insulation
off the end of the speaker wire, press in the
tab, and insert the bare wire into the hole.
When you release the tab, the wire is locked in
place. Make sure there are no stray strands of
wire outside the terminal connection.
+–
INPUT
0
10W
25W
50W
BYPASS
4
50V
25V
70V
0
100V
WARNING: Consult a professional rigger or
structural engineer prior to suspending
loudspeakers from a structure not intended
for that use. Always know the working load
limit of the structure supporting the
loudspeaker array. Always make sure that
the rigging hardware minimum rating is at
least five times the actual load.
4
MR6T/MR6WT
Specifications
System:
Freq. Range (–10 dB):
Freq. Response (–3 dB):
Coverage Angle (–6 dB):
Directivity Factor Q (DI):
System Sensitivity
Rated Maximum SPL:
Rated Nominal Impedance:
System Input Power Rating
Constant Voltage:
Power Taps:
70Hz-18kHz
200Hz-15kHz
90°, averaged 800Hz-16kHz
9.3 (9.7), averaged 800Hz-16kHz
1
:
95 dB, 1W@1m
118 dB @ 1 m (3.3 ft) peak
4Ω (bypassed)
50W IEC, 200W Peak
25V, 50V, 70V, 100V
10W, 25W, 50W
Physical:
Enclosure:
Attachment Inserts:
Color:Matte black (MR6T)
Grille:Matching perforated steel grille
Input Connectors:
Dimensions HxWxD:
Net Weight:
2
:
45° back angles, high density
polystyrene
4 points M6 threaded
White (MR6WT)
Spring-loaded terminal
11.82 in x 8.39 in x 8.96 in
(300 mm x 213 mm x 228 mm)
15.0 lb (6.8 kg)
Transducer:
Full Frequency:
1
Measured on-axis in the far field with 1 watt (2.00V RMS @
4Ω ) input and referenced to 1 meter distance using the
inverse square law. Listed sound pressure represents an
average from 300Hz to 3kHz.
2
RMS using 20 Hz to 20 kHz, PN Spectrum, peak for 2
hours with +6 dB crest factor.
6.3" (160 mm) dual-cone woofer with
1.5" (38mm) coil
5
16220 Wood-Red Road NE, Woodinville, WA 98072 USA
www.mackieindustrial.com
TEL 888.337.7404, FAX 425.487.4337, industrial@mackie.com
UK +44.1268.571.212, FAX +44.1268.570.809 +industrial@rcf-uk.com