Read all Instructions before Installing and operating this appliance
• The installation instructions in this guide are intended for qualified installers, service technicians or persons
with similar qualified background.
• Installation and electrical wiring must be done by a qualified professional and in accordance with all
applicable codes and standards, including for fire-rated construction.
• The range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any
parts for installing, cleaning or servicing.
• Activating any switch ON before completing installation may cause ignition or an explosion.
• Due to the size and weight of this range hood, it is recommended that two people handle the installation.
To reduce the risk of fire, electric shock or injury:
• This range hood is for general ventilating use only. DO NOT use to exhaust hazardous or explosive materials
or vapors.
• Before servicing or cleaning the unit, switch power to OFF at the electric panel and lock it to prevent power
from being switched ON accidentally.
• Clean grease-laden surfaces frequently; to reduce the risk of fire and to disperse air properly, make sure to
vent air to the outside. DO NOT vent exhaust into spaces between walls or crawl spaces, or into ceiling, attic or
garage.
• ALWAYS vent ducted fans to the outside.
• Use only metal ductwork. ALWAYS ground the unit.
• To prevent back drafting, ensure there is sufficient air for proper combustion and exhausting of gases
through the duct.
• When cutting or drilling into a wall or ceiling, take care not to damage electrical wiring or other hidden
utilities.
• Ensure that all electrical wiring is properly installed, insulated and grounded.
• Clean old duct work or replace it if necessary to avoid the possibility of a fire due to old accumulations of
grease.
• Check all joints on duct work to ensure proper connections. Tape all joints properly.
• Use this unit only in the manner intended by the manufacturer. If you have questions, contact LUX.
To reduce the risk of a stove-top grease fire:
• Keep fan, filers, exhaust duct, grease container and grease-laden surfaces clean; grease should not be
allowed to accumulate anywhere in the range hood.
• Always turn range hood ON when cooking, especially when cooking at high heat or with an open flame.
• Use the highest heat settings only when necessary.
• Never leave the cooking surface unattended at a high setting; boiling liquids cause smoke and grease may
ignite; heat cooking oils slowly on low or medium settings.
Read all instructions before installing and operating this appliance
• Clean the ventilating fan frequently.
• Always use appropriate cookware and properly sized utensils.
• Always use cookware appropriate for the size of the surface element.
To reduce the risk of injury in the event of a stove-top grease fire:
• SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn OFF the burner. TO PREVENT
BURNS NEVER PICK UP A FLAMING PAN; KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM
FLAMES. If the flames DO NOT go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT, or dial your
local emergency service immediately.
• DO NOT USE WATER, including wet dishcloths or towels, as this may cause a violent steam explosion.
• Use an extinguisher ONLY if:
• You have a Class A, B or C extinguisher and you know how to operate it.
• The fire is small and contained in the area where it started.
• The fire department has been called.
• You can fight the fire with your back to an exit
To reduce the risk of injury to persons in the event of a gas leak:
• Extinguish any open flame.
• DO NOT turn on the range hood fan or any type of ventilator.
• DO NOT turn on the lights or any type of appliance.
• Open all doors and windows to disperse the gas; if you still smell gas, call the gas company and fire
department, or dial your local emergency service immediately.
Your safety and the safety of others is paramount. Read and obey all important safety instructions we have
provided in this guide. Safety instructions will tell you what the potential hazard is, how to reduce the chance
of injury, and tell you what can happen if the instructions are not followed.
WARNING
This is the safety alert symbol we use to alert you to potential hazards. All safety messages will follow the
safety alert symbol and the word “WARNING”.
LUX and its authorized dealers decline all responsibility in the event of failure to observe the instructions
given here for installation, maintenance and suitable use of the product.
LUX and its authorized dealers further decline all responsibility for injury due to negligence.
The warranty of the unit automatically expires due to improper maintenance.
LUX and its authorized dealers will not be held responsible for any damages to personal property or real
estate or any bodily injuries, whether caused directly or indirectly by the range hood.
• A 6” round duct (standard for this range hood) or 3-1/4” x 10” rectangular duct (purchased separately) must
be used to maintain maximum airflow efficiency.
• A flexible 6” round duct is provided for installation in decorative chimneys. Always use rigid metal/aluminum
ducts, if available, to maximize airflow when connected to provided duct.
• If turns or transitions are required, keep them as far away as possible from either end of the duct work. If
multiple turns or transitions are required, keep them spaced sufficiently far apart so as not to impede the
airflow.
• Clearance between stove top and hood bottom should be no less than 30” and no more than 33”.*
• It is important to install the range hood at the proper height. Range hoods mounted too low could sustain
heat damage and become a fire hazard while hoods mounted too high will be hard to reach and will not
perform optimally.
• If possible, also refer to the stove manufacturer’s height clearance requirements and recommended hood
mounting height above the range.
* Due to different ceiling height configurations, recommended height may not be applicable.
• Please follow your area’s effective building and gas codes as well as your municipal regulations.
Minimum Duct Size:
• Round, 6” minimum
• Rectangular, 3-1/4” x 10” minimum (requires a 6” to 3-1/4” x 10” adaptor, not supplied)