LUX LUX/GEO Quick Start Manual

GEO
WiFi THERMOSTAT
Welcome to your LUX/GEO™ quick-start guide
Your LUX/GEOTM internet connected thermostat puts the control of your comfort in your hands and you are only 10 easy steps away from installation.
Step 1: Getting started
Locate and gather the following items for ease of installation
Download App and Create Your Account
Included:
Items needed:
IF AT ANY TIME DURING THE INSTALLATION AND SET-UP PROCESS YOU NEED ADDITIONAL SUPPORT, VISIT LUX-GEO.COM OR CALL 856.234.8803
2-AA Lithium batteries
2 screws
2 wall anchors
wire stripper
& cutter
phillips & at
head screwdriver
WiFi enabled
mobile device
WiFi
router
Download your LUX/GEO App
Depending on device type, search the App store for “LUX GEO” and create your LUX/GEOTM user account
IF YOU DO NOT HAVE AN iOS OR ANDROID DEVICE, PLEASE VISIT LUX-GEO.COM.
Step 2: Switch power o
IMPORTANT: Turn o the power at circuit breaker to both your heating & cooling systems before performing any wiring.
WATCH
OUR VIDEO
DEMO LUX-GEO.COM
Step 3: Remove existing thermostat & install GEOTM
 Remove front of existing thermostat from base
 Photograph current wiring for reference
 Release wires and mounting screws and
remove base from wall
 Open GEO™ from base, pull up on plastic
“cover” between terminal blocks to access and pull wires through.
 Secure GEO base to wall (mounting
hardware & optional wall plate included)
REMOVE
TERMINAL
COVER
TAKE
PHOTO OF
CURRENT
WIRING
HOLD
AND
PULL TO
OPEN GEO
GEO
RETURN
TERMINAL
COVER
Y1
RC RH
RESET
W1
IMPORTANT: If you have both an RC and RH wire present then
remove the RED RC-RH shorting cap found on inside front of GEOTM.
 Wiring is complete - you may return “cover” between terminal blocks.
GAS / OIL / ELECTRIC FURNACE and/or AIR CONDITIONING [typical wire color used] (typical)
RH (or R) = 24(+) VAC Power, Heat [RED] W1 = 1st Stage Heat [WHITE] G = Blower Fan [GREEN] C = 24(-) VAC Common [BLUE] Y1 = 1st Stage Cool [YELLOW]
(other)
RC = 24(+) VAC Power, Cool B = Heat Mode Damper O = Cool Mode Damper W2 = 2nd Stage Heat Y2 = 2nd Stage Cool
4.1 Wiring Terminal Reference: Conventional Furnace – gas/oil/electric & air-conditioning*
*for heat pump systems - see section 4.2
FOR A DETAILED WIRING GUIDE VISIT LUX-GEO.COM.
Referencing your wiring photo & terminal guide below, wire to GEO.
Step 4: Powering & wiring LUX/GEO
TM
*Notice for battery installations:
 Batteries should be replaced at least once per year, but
depending on your settings may need to be replaced sooner.
 Battery failure could leave property without controlled
heating or cooling. Reliance on battery power is not recommended with prolonged absence from property.
 After installation you can choose to set the
“energy profile” for your GEOTM This energy profile will determine the delay in GEOTM responding to changes from the App.
 GEOTM should only be used with lithium batteries.
AS AN ADDED RESOURCE, A GLOSSARY OF TERMS IS AVAILABLE ON LUX-GEO.COM
NOTE: System compatibility
For Use On:
 Most 24-volt heating and cooling systems  1 or 2 stage heat / 1 or 2 stage cool: gas, oil, or electric
furnace and a/c systems
 1 or 2 stage heat / 1 stage cool: heat-pump style systems  2-wire hydronic (hot water) zone valves  Gas Millivolt wall/floor heaters
Not For Use On:
 120/240 VAC line-
voltage systems (without a transformer)
 Heat pumps that
have (Y2) two compressor stages
WIRES INSERT INTO SIDE OF TERMINAL, UNDER SCREWS.
GEOTM needs only 1 of 3 power source options:
 C-terminal (Recommended & for optimal performance.
Reference photo from step 3 to confirm C-wire.)
 Battery* (2-AA Lithium included)  USB micro-port available on GEOTM
(adapter & cord not included; recommend 1A adapter)
Step 5 provides detail on battery & USB connection