Lucent Technologies PacketStar AC 60 User Manual

Doc. No.: 255-700-025 COMCODE: 300303021
PacketStar™ Access Concentrator 60 User Guide
A PacketStar™ PSAX Central Office Product
Issue 1, October 2000 System Software Release 6.3.0 AQueView™ EMS Software Release 4.4
Copyright © 2000 by Lucent Technologies. All rights reserved.
For trademark, regulatory compliance, and related legal information, see the "Copyright and Legal Notices" section.
255-700-025 iii
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Copyright and Legal Notices
Copyright
Copyright © 2000 by Lucent Technologies. All rights reserved.
This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts or licensing, without the express written consent of the InterNetworking Systems, Access Technology organization and the business management owner of the material.
This document was prepared by the Information Design and Development department of Lucent Technologies, InterNetworking Systems, Access Technology group. Offices are located in Landover, Maryland, U.S.A.
Trademarks
AQueView, PacketStar, Lucent, Lucent Technologies, and the Lucent Technologies logo are trademarks of Lucent Technologies in the U.S.A. Other product and brand names mentioned in this guide are trademarks or registered trademarks of their respective owners.
Warranty Information
Software and Hardware Limited Warranties
Lucent Technologies provides a 90-day limited software warranty, and a one­year limited hardware warranty on this product. Refer to the Software License
and Limited Warranty Agreement and the Lucent Technologies InterNetworking Systems Global Warranty that accompanied your package for more
information.
Every effort has been made to ensure that this document is complete and accurate at the time of release, but information is subject to change. Lucent Technologies assumes no responsibility or liability for errors or inaccuracies that may appear in this guide.
Copyright and Legal Notices
Warranty Information
iv 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Warranty Warnings
!
CAUTION:
Do not make electrical or mechanical modifications to any of the components in the PSAX system. Lucent Technologies is not responsible for the safety or the performance of a modified Lucent product. Do not attempt to repair any failed Power Supply module, Stratum 3–4 module, CPU module, I/O, or Server module.
!
CAUTION:
Do not make electrical or mechanical modifications to any of the components in the PSAX system. Lucent Technologies is not responsible for the safety or the performance of a modified Lucent product. Do not attempt to repair any failed removable I/O or server modules.
!
CAUTION:
Modifying or tampering with PSAX chassis components may void your warranty. Any modification to this equipment not expressly authorized by Lucent Technologies may void your granted authority to operate such equipment.
!
CAUTION:
Air vents in the PSAX chassis are provided to aid in ventilation and to protect from overheating. These vents must be regularly inspected by the user and cleared of dust and blockage. Equipment failure associated with improper maintenance or suspected failure to adhere to proper ventilation procedures as described above will void your warranty.
!
CAUTION:
You must replace an air filter having an accumulation of dust to ensure adequate airflow through the PSAX chassis. Reduced airflow could result in damaging heat buildup within the chassis.
Periodically inspect the air filter for accumulated dust and replace the filter as needed. At a minimum, monthly inspection is recommended. Equipment failure due to inadequate airflow voids your equipment warranty.
Use only filters supplied by Lucent Technologies in your PSAX chassis. Use of other filters voids your equipment warranty.
!
CAUTION:
You must maintain a minimum 5.08 cm (2 in) of clearance around the chassis for adequate airflow. Failure to adhere to this space requirement may result in equipment failure due to overheating. Failure to provide a minimum of 5.08 cm (2 in) of clearance between this unit and any other device/structure will void your warranty.
255-700-025 v
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Copyright and Legal Notices
Regulatory Standards Compliance
!
CAUTION:
If your system or location loses power or your current session ends abnormally while you are in the process of configuring the system, and you have not yet saved the values permanently, you will lose all unsaved values you have applied on the various windows.
!
CAUTION:
Shipping the chassis with removable modules installed may cause damage to the chassis and the modules. Damage to any of the components in the system resulting from shipping the chassis with removable modules installed could void your warranty. Only Lucent­authorized personnel should ship the AC 60 chassis with a module installed.
Regulatory Standards Compliance
The PacketStarAccess Concentrator 60 is fully compliant with the following environmental, safety, and emissions standards. Appropriate statements appear in the next subsection.
Safety Requirements
Underwriter’s Laboratory (UL) — Safety and Factory Compliance
UL 1950
CB-Scheme — IEC 60950:1991+A1:1992+A2:1993+A3:1995+A4:1996
Electromagnetic Compatibility (EMC) and Physical Requirements
Federal Communications Commission (FCC) — EMC compliance
(Part 15 Class A)
EN 55022:1994 Class A (CISPR22:1993)
EN 50082-1:1992
CE Marking
CE marking of the Lucent Technologies AC 60 ATM Access Concentrator consisting of the following model numbers:
50S02, 50S48, 20A13, 20N07, 20N16, 20N22, 20N27, 20N28, 20N29, 20N34, 20N40, 20N41, 20N56, 20N62, 20N63, 20N64, 20N65, 20N92, 20N93, 23N27, 23N66
Copyright and Legal Notices
Regulatory Statements
vi 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
is based upon conformity with the following standard(s) or other normative document(s):
EN 55022:1994 Class A
EN 50082-1:1992
EN 60950:1992+A1:1993+A2:1993+A3:1995+A4:1997+A11:1997
CTR 4/A1 as specified in Commission Decision 98/520/EC
CTR 12/A1 as specified in Commission Decision 97/520/EC
CTR 13 as specified in Commission Decision 97/521/EC
CTR 24 as specified in Commission Decision 97/639/EC
in accordance with the provisions of the following Council directives:
Electromagnetic Compatibility (EMC) 89/336/EEC
Low Voltage 73/23/EEC
Telecommunications Terminal Equipment and Satellite Earth Station
Directive 98/13/EC
The European Community Declarations of Conformity for the PacketStar™Access Concentrator 60 are included in the EC Declarations of Conformity Appendix in the back of this guide.
Regulatory Statements
United States Federal Communications Commission (FCC) Statements
Part 15. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with this guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference; in this case, you would be required to correct the interference at your own expense.
All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals, that are not shielded and grounded may result in interference to radio and television reception.
255-700-025 vii
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Copyright and Legal Notices
Regulatory Statements
The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Part 68. This equipment complies with Part 68 of the FCC rules. On the back of the AC 60 chassis is a label that contains the FCC registration number, in addition to other information. You must provide this information to the telephone company, if they request it. The FCC requires Lucent Technologies, Inc., to provide you with the following information:
1. The AC 60 system has digital service interface capabilities using RJ-48C and RJ-48H connectors. The facility interface codes with which the AC 60 system complies for digital services are as follows: 04DU9-BN, 04DU9-DN, 04DU9-1KN, and 04DU9-1SN. The AC 60 system has loop start interface capabilities using an RJ-11C connector. The facility interface code with which the AC 60 system complies for service is 02LS2. The service order codes for the AC 60 system are 6.0F for the T­1 interface and 9.0Y for the loop start interface.
2. An FCC-compliant telephone network interface jack is built into this equipment and is compatible with interconnections that are Part 68 compliant.
3. The REN for the Voice 2-Wire Office module when used in the AC 60 system is 0.7B.
4. If the AC 60 system causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service might be required. But if advance notice is not practical, the telephone company will notify you as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe this is necessary.
5. The telephone company might make changes in its facilities, equipment, operations, or procedures that could affect the operation of this equipment. If this happens, the telephone company will provide advance notice for you to make necessary modifications to maintain uninterrupted service.
6. If you experience trouble with the AC 60 system, or need repairs or warranty information, please refer to the Limited Hardware Warranty card that accompanied your AC 60 product shipment for instructions on obtaining technical support in your area.
If the AC 60 system is causing harm to the telephone network, the telephone company might request that you disconnect the equipment until the problem is resolved.
7. This equipment has no user-serviceable parts.
This equipment cannot be used on public coin telephone service provided by the telephone company. Connection to party line service is subject to state tariffs. Contact your state public utility commission, public service commission, or corporation commission for information.
Copyright and Legal Notices
Regulatory Statements
viii 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Canadian Regulatory Statements
Industry Canada Information
Ringer Equivalence Number (REN) Notice. The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee that the equipment will operate to the user’s satisfaction.
Before installing this equipment, the user should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed by using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single-line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations.
Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier. Any repairs or alternations made by the user to this equipment or equipment malfunctions might give the telecommunications company cause to request the user to disconnect the equipment.
For their own protection, users should ensure that the ground connections of the power utility, telephone lines, and internal metallic water pipe system are connected together. This precaution may be particularly important in rural areas.
!
CAUTION:
Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority or electrician.
The Ringer Equivalence Number (REN) assigned to the Voice 2-Wire Office module denotes the percentage of the total load to be connected to a telephone loop, which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the REN of all devices does not exceed 5.
The REN for the Voice 2-Wire Office module when used in the AC 60 system is 0.7B.
Renseignements Industrie Canada
Avis de nombre équivalent de sonneries (REN). Le label Industrie Canada permet de reconnaître les équipements homologués. Cette homologation indique que l’équipement satisfait certaines règles de protection, d’exploitation et de sécurité des réseaux de télécommunications. Le ministère de l’Industrie ne garantit pas que l’équipement fonctionnera à la satisfaction de l’utilisateur.
Avant d’installer cet équipement, l’utilisateur doit s’assurer qu’il est permis de le connecter aux installations de la compagnie de télécommunications locale. L’équipement doit également être connecté suivant une méthode
255-700-025 ix
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Copyright and Legal Notices
Regulatory Statements
convenable. Dans certains cas, il sera nécessaire de prolonger le câblage intérieur de la ligne d’abonné de la compagnie au moyen d’un connecteur homologué (rallonge de téléphone). L’abonné doit savoir que, dans certaines situations, la conformité aux dispositions ci-dessus ne prévient pas nécessairement la dégradation du service.
La réparation de certains équipements homologués doit être assurée par un atelier agréé désigné par le fournisseur. Toute réparation ou altération effectuée par l’utilisateur ou tout mauvais fonctionnement de cet équipement peut donner à la compagnie de téléphone des raisons de demander audit utilisateur de déconnecter celui-ci.
Pour leur propre sécurité, les utilisateurs doivent veiller à ce que les mises à la terre de l’alimentation secteur, des lignes téléphoniques et du système intérieur de conduites d’eau métalliques soient raccordés ensemble. Cette précaution peut s’avérer particulièrement importante dans les zones rurales.
!
CAUTION:
Les utilisateurs ne doivent pas tenter d’effectuer eux-mêmes ces raccordements, mais doivent prendre contact avec un électricien ou organisme de vérification compétent.
Le nombre équivalent de sonnerie (REN) attribué au module central bifilaire (Voice 2-Wire Office) correspond au pourcentage de la charge totale à connecter à un circuit téléphonique bifilaire; il est utilisé par l’appareil pour prévenir la surcharge. Le circuit peut être terminé par n’importe quelle combinaison d’appareils, à la seule condition que le total des REN de ces derniers ne dépasse pas cinq.
International Regulatory Statements
CISPR22. This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
Copyright and Legal Notices
Regulatory Statements
x 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
255-700-025 xi
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Safety Warnings and Information
When installing and operating the PacketStarAccess Concentrator 60, follow the safety guidelines provided below to help prevent serious injury and/or damage to the AC 60 equipment. Please read all warnings and instructions supplied before beginning installation or configuration of the AC 60 equipment. In addition to the general safety information provided below, you should also refer to the text in the user and installation guides for other important safety information and procedures.
!
DANGER:
Never push and/or place an object in or through any vent in the AC 60 chassis. Doing so may result in personal injury, equipment damage, or both. Touching exposed electrical components may cause injury.
!
DANGER:
Install only equipment identified in the installation guide for the AC 60 system. Using other equipment may result in improper connection of circuitry, which may lead to equipment fire, personal injury, or equipment damage.
!
DANGER:
Do not install or use the AC 60 unit in wet locations. In the event the unit becomes wet, turn it off, disconnect it from the facility power source, and allow the unit to dry thoroughly. If, after this procedure, you encounter problems with the performance of the unit, please contact your NetworkCare Service Center. (See the Lucent Technologies InterNetworking Systems Global Warranty that accompanied your shipment for the appropriate telephone number.)
!
DANGER:
When removing an alternating current (AC) power cord from an AC 60 chassis running on AC power, remove the power cord from the connector by grasping and pulling the plug, not the power cord.
!
DANGER:
Ensure that the voltage and frequency of the facility power source match the requirements of the AC 60 Power Supply unit. The AC 60 system should only be operated from the power source type indicated on the marking label. Failure to meet this requirement may cause personal injury, fire, and/or damage to the unit.
!
DANGER:
Shock hazard! Do not personally perform any maintenance on this equipment. This equipment does not contain any user serviceable parts. Maintenance is to be performed only by qualified personnel.
Safety Warnings and Information
xii 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
!
DANGER:
The OC-3c Single Mode (SM) and the STM-1 Single Mode (SM) modules contain a laser-generating device, which emits a laser light beam from the transmit port. This port is labeled TX on the module faceplate. When the module is inserted into an operational AC 60 chassis, personal injury may result from looking into, or near, either port. Personal injury may also result from looking into, or near, the far end of a connected fiber optic cable. For additional laser safety information, see Appendix B of the OC-3c Multi-Mode and Single-Mode Module Guide, the OC-3c Multi-
Mode and Single-Mode 1+1 APS Module Guide, the STM-1 Multi-Mode and Single-Mode Module Guide, and the STM-1 Multi-Mode and Single­Mode 1+1 MSP Module Guide.
!
DANGER:
Interface lines connected to the Voice 2-Wire Office module (model number 20N32) that exit the building premises must be connected to any nationally recognized testing laboratory (NRTL) listed telecommunications protection device that provides primary and secondary protection. These protection devices provide overvoltage protection to the Voice 2-Wire Office module interface lines.
!
DANGER:
Read all installation instructions before connecting the system to a power source.
!
DANGER:
Do not work on the system, connect, or disconnect cables during periods of possible lightning activity.
!
DANGER:
Do not perform any action that could create a possible hazard to others or make the working environment and/or the equipment unsafe.
WARNING:
!
Be sure to cover all empty slots with blank faceplates to protect your equipment.
WARNING:
!
This product relies on the building’s installation of short-circuit (over­current) protection. Ensure that a fuse or circuit breaker no larger than 120 V ac, 15 A U.S. (240 V ac, 10 A international) is used on the phase conductors (all current-carrying conductors).
WARNING:
!
Once the AC 60 chassis is operational (power is applied to the chassis) and the OC-3c SM or STM-1 SM module is fully inserted into the chassis backplane, use extreme caution during removal of the fiber optic cable from one or both ports. Keep the protective port caps supplied with these two types of modules nearby (for example, taped to the cable for
255-700-025 xiii
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Safety Warnings and Information
the port), and place said cap on the port immediately after removing the cable from an operational module.
WARNING:
!
If you place the AC 60 chassis on or near the floor, dust or debris may accumulate faster inside the chassis than it would if placed on a table or standing structure. Therefore, if this unit is placed on or near the floor, accelerated routine vent and air filter inspection is necessary to avoid the risk of unit failure and/or injury to property or persons.
WARNING:
!
Be sure to use the ejector handles during installation and removal of I/O and server modules.
WARNING:
!
When inserting modules into the chassis, slide them gently, not forcefully. Excessive force may cause the modules to be seated improperly in the chassis, and result in possible damage to the module or the chassis.
WARNING:
!
Electrostatic discharge (ESD) can damage module and chassis components. All personnel should be grounded and follow proper ESD procedures before installing, removing, or handling AC 60 components.
WARNING:
!
The AC power cord is rated at 125 V ac. If you will be using this unit in an application above 125 V ac, you must source an appropriate Agency­approved cordset.
WARNING:
!
You must maintain the minimum 5.08 cm (2 in) of clearance on both sides of the chassis for adequate airflow, or the equipment might fail due to overheating. If you place the unit on or near the floor, dust will accumulate faster inside the chassis.
WARNING:
!
Interface lines connected to the Voice 2-Wire Station module must be connected only to telephone sets. Do not connect these station port interface lines to Public Switched Telephone Network (PSTN) type interfaces.
!
CAUTION:
If your system or location loses power or your current session ends abnormally while you are in the process of configuring the system, and you have not yet saved the values permanently, you will lose all unsaved values you have applied on the various windows.
!
CAUTION:
Ultimate disposal of this product should be handled according to all laws and regulations in your specific geographic region.
Safety Warnings and Information
xiv 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
!
CAUTION:
Install or remove modules one at a time. Doing this aids in preventing the AC 60 system from indicating any erroneous failure messages, and allows the AC 60 system to reinitialize and display the accurate configuration of the module that is inserted.
!
CAUTION:
When using a DSP2A, DSP2B or DSP2C Voice Server module and an Enhanced DS1/E1 module with a PBX and/or Key Telephone System, the AC 60 system and your equipment must use a common chassis ground connection to avoid ground current loops, which could affect voice quality.
255-700-025 xv
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Contents
Copyright and Legal Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Copyright. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Warranty Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Software and Hardware Limited Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Warranty Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Regulatory Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Safety Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Electromagnetic Compatibility (EMC) and Physical Requirements . . . . . . . . . . . . . . . . . v
CE Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
United States Federal Communications Commission (FCC) Statements . . . . . . . . . . . . . vi
Canadian Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Industry Canada Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Renseignements Industrie Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
International Regulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Safety Warnings and Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
1 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Purpose of This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Audience for This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
What You Should Know . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Related Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Lucent Technologies Information Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Product Information Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Printed Documents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
Other Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6
Text Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8
Text Types Used in This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8
Icons and Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9
Electrostatic Discharge (ESD) Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9
Grounding Wrist Straps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-10
Floor Covering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-10
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-11
Contents
xvi 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Clothing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
Handling Chassis, Modules, and Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
About Lucent Technologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
For More Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Comments on This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
2 Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
System Hardware Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Chassis Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Stratum 3–4 Clock Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Central Processing Unit Component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
AC 60 System Hardware Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
AC 60 System Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Facility Power Source Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
AC 60 CPU and Stratum Component Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
AC 60 Physical Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
I/O and Server Modules Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
3 System Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
System Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Interface Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
User Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Circuit Emulation Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Dynamic Bandwidth Circuit Emulation Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
DS1 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
DS3 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
HDLC Pass-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
The Interim Interswitch Signaling Protocol (IISP) Interface . . . . . . . . . . . . . . . . . . . . . 3-6
Private Network-Network (PNNI) 1.0 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
PNNI Features Supported By the PSAX Systems . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Peer Group Dynamics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Topology Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
PNNI Hierarchies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
The ATM Terminal Emulation Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
Contents
255-700-025 xvii
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Network Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9
In-band Management SVCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-11
AQueView™ Element Management System . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-11
Navis Integration, Phase 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-11
AC 60 Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-13
Alternate Rerouting Using Dual-Homed PVCs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-13
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-13
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-14
Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-14
AQueMan™ Algorithm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-15
Connection Gateway API . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-19
Console Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-19
Ethernet LAN Bridging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-20
Firmware Release Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-21
Forward Error Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-22
Frame Relay-to-ATM Interworking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-24
FRF.5 Encapsulating Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-24
FRF.8 Converting Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-24
Frame Relay-to-Frame-Relay Interworking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-24
Integrated Link Management Interface (ILMI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-24
Inverse Multiplexing over ATM (IMA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-25
LANET Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-25
Operations, Administration, and Maintenance (OAM) . . . . . . . . . . . . . . . . . . . . . . .3-27
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-27
OAM Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-28
OAM Cell Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-28
F4/F5 Flows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-28
Fault Management Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-29
Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-29
Reporting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-30
Localization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-31
Activation/Deactivation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-32
Characteristics of OAM Activation / Deactivation Cells . . . . . . . . . . . . . . . . . . . .3-32
Module-Specific Alarm Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-32
Loss of Signal (LOS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-32
Loss of Frame (LOF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-34
Alarm Indicator Signal (AIS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-34
Remote Defect Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-35
Soft Permanent Virtual Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-35
Contents
xviii 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Switched Virtual Circuits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-36
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-36
Call States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-37
Traffic Shaping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40
Voice Compression. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-42
Voice Processing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-42
I/O, Optical, and Server Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43
I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43
Optical-Type I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-44
Server Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-44
Channelized DS3 Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-45
Software Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-45
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46
Channelized STS-1e (T1) Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46
Software Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-47
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-48
DS1 IMA Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-48
Software Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-48
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-48
DS3 ATM Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-49
Software Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-49
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-49
DS3 Frame Relay Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-49
Software Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-49
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-50
DS3 IMA Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-50
Software Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-51
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-51
DS3 ATM Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-51
Software Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-52
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-52
DS3 Frame Relay Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-52
Software Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-52
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-53
E1 IMA Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-53
Software Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-54
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-54
E3 ATM Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-54
Software Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-54
Contents
255-700-025 xix
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Hardware Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-55
Enhanced DS1 Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-55
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-56
Hardware Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-56
Enhanced E1 Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-57
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-57
Hardware Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-58
Ethernet Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-58
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-59
Hardware Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-59
High-Speed Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-59
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-59
Hardware Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-60
Medium-Density DS1 Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-60
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-61
Hardware Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-61
Multi-Serial Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-62
Bit Stuffing and CES Conversion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-62
Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-62
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-62
Frame Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-63
Circuit Emulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-63
Terminal Emulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-63
HDLC Pass-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-64
ATM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-64
Hardware Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-64
Voice 2-Wire Office Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-65
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-65
Voice 2-Wire Station Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-65
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-65
Hardware Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-66
Optical-Type I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-66
OC-3c Multi-mode and Single-Mode Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-66
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-66
Hardware Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-67
STM-1 Multi-Mode and Single-Mode Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-68
Software Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-68
Hardware Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-69
Server Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-69
Contents
xx 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
DSP2 Voice Server Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-69
Software Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-70
DSP2C Voice Server Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-72
Multiplexed or Nonmultiplexed AAL-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-72
Dynamic DSP Resource Allocation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-73
Caller ID/Flash Hook Signalling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-73
Hybrid A, B and C Mode Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-73
Previous Version Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-73
Soft Permanent Virtual Circuit Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-73
Voice Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-73
Silence Suppression Comfort Noise. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-74
DSP2A and DSP2B Single-Mode Voice Server Modules (System Release 6.2.0) . . . . 3-74
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-75
Route Server Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-75
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-76
Tones and Announcements Server Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-77
Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-77
4 Configuring the Basic System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Logging onto the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Help Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Selecting Options, Fields, and Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Changing the System Password and Other User Options. . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Console Interface Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Configuring the System for Your Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
System Identification Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Rules for Configuring IP Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Rules for Configuring IP Address Masks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Configuring System Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
ATM Addresses and OAM Properties. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Entering and Displaying ATM Addresses and OAM Properties . . . . . . . . . . . . . . 4-12
Configuring System Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
System Date and Time Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
Configuring the TCP Client/Server for a Connection Gateway. . . . . . . . . . . . . . . . . 4-17
Connection Gateway Application Programming Interface . . . . . . . . . . . . . . . . . 4-18
Configuring the TCP Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
Configuring SNMP Trap Destinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20
Configuring In-Band Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
Contents
255-700-025 xxi
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Adding an In-Band Management ATM SVC Connection. . . . . . . . . . . . . . . . . . . . . .4-22
Preparing for an In-Band Management SVC Connection . . . . . . . . . . . . . . . . . .4-23
Creating an In-Band-Management SVC Connection . . . . . . . . . . . . . . . . . . . . . .4-24
Viewing In-Band Statistics Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-32
Deleting an In-Band Management SVC Route . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-34
Using the Equipment Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-34
Configuring the Stratum 3–4 Clock Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-36
Setting the Stratum Configuration Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-36
Switching the Line Timing Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-39
Configuring I/O and Server Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-40
Alarm Status Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-40
PNNI System-Wide Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-41
Configuring PNNI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-41
Configuring PNNI Route Addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-49
Configuring PNNI Metrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-53
Configuring Summary Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-57
Viewing the PNNI Map Link Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-60
Viewing the PNNI Link Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-64
Viewing the PNNI Neighbor Peer Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-70
Viewing PNNI System Statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-73
Configuring Call Control Resource Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-76
Setting the Configuration Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-77
Configuration Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-78
Saving the Configuration and Rebooting the System . . . . . . . . . . . . . . . . . . . . . . . .4-82
Backing Up Your Configuration Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-83
5 Using System Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1
Viewing System Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1
Running Cell Test Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-5
Cell Test Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-5
Rebooting PSAX Hardware Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-10
Rebooting the PSAX System Hardware Components . . . . . . . . . . . . . . . . . . . . .5-10
Removing Configuration Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-12
Removing Configuration Files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-12
Unlocking a Telnet Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-13
Unlocking a Telnet Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-13
Operations Administration and Maintenance (OAM). . . . . . . . . . . . . . . . . . . . . . . . . . . .5-14
Creating OAM Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-14
Contents
xxii 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Monitoring OAM Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-24
Performing OAM Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27
OAM Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27
OAM Activation and Deactivation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-29
Activating and Deactivating OAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
6 Using VT100 Terminal Emulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1
Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
Setting Up The Windows 3.1 Terminal Emulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
Setting Up The Windows 95 HyperTerminal Emulator . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
Other Software for VT100 Terminal Emulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
Setting Up a U.S. Robotics-Compatible Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
7 Upgrading, Restoring, and Backing Up System Software and Firmware . . .7-1
Overview of This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
Directory Structures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
Installing a New Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
Setting Up a Windows FTP Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
Upgrading System Software Using FTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
Upgrading Using XModem/YModem File Transfer Method . . . . . . . . . . . . . . . . . . . . . . . 7-9
Setting Up for the File Transfer Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9
Transferring Software Upgrade Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10
Field Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12
Upgrading Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-16
Firmware Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-16
Upgrading I/O and Server Module Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-18
Selecting Firmware Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-21
Falling Back to the Previous Software Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-22
Backing Up System Database Files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-24
Configuration and Connections Data Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-24
Backing Up Database Files Using FTP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-24
Backing Up Database Files Using FTP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-25
Backing Up Database Files Using XModem/YModem File Transfer. . . . . . . . . . . . . . 7-26
Setting Up for the File Transfer Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-26
Copying the Database Files to a Storage Medium . . . . . . . . . . . . . . . . . . . . . . . 7-27
Restoring System Database Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-30
Configuration and Connection Data Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-30
Restoring Database Files Using FTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-30
Restoring Database Files Using FTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-31
Contents
255-700-025 xxiii
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Rebooting the AC System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-32
Restoring Database Files Using XModem/YModem File Transfer . . . . . . . . . . . . . . . .7-32
Setting Up for the File Transfer Process. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-33
Copying the Backup Files to the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-33
Rebooting the AC System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-36
Appendix A: SNMP Trap Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Overview of This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Viewing SNMP Trap Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Definitions of MIB Objects Used for Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-43
Appendix B: Pin Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
Overview of This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1
Configuration for the Power Supply Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1
AC Power Supply Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1
Configuration for the CPU Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-2
Console Serial Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-2
Ethernet 10Base-T Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-3
Configuration for the Stratum 3–4 Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-3
Appendix C: Configuring In-Band Management . . . . . . . . . . . . . . . . . . . . . . . . C-1
Setting Up In-Band Management Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
Using the Direct Connection Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2
Using the Routed Connection Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-4
Setting PVC Connections for Routed Connection Configuration. . . . . . . . . . . . . C-7
Using the Hybrid Connection Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-10
Setting PVC Connections for Hybrid Connection Configuration . . . . . . . . . . . . C-12
Appendix D: ATM Traffic Descriptors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1
Overview of This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1
Connections Supporting Traffic Descriptors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1
Traffic Descriptors Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1
Appendix E: Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1
Overview of This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1
QoS Information Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1
Compliance Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-4
Module Alarm Status Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-9
Connection Type by Interface Type Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-10
Interface Type by Module Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-12
Contents
xxiv 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Appendix F: European Community Declarations of Conformity . . . . . . . . . . .F-1
Overview of This Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F-1
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
255-700-025 1-1
1 Getting Started
Purpose of This Guide
The PacketStar Access Concentrator 60 User Guide provides information about the following:
Understanding the AC 60 system functions and features
Configuring basic system parameters and managing the AC 60 system
Note: If you are setting configuration values for a new, unconfigured
PSAX device for the first time, you should read through this guide before beginning the configuration process.
Note: If you are using this module to provisioning connections for the
first time, you should read through this guide before beginning the provisioning process.
Audience for This Guide
The information in this guide is intended for people who will configure and maintain the basic AC 60 system.
What You Should Know
Before you use this document or operate the AC 60 chassis you should already understand and have experience with the following:
ATM Forum and Frame Relay Forum specifications
Ethernet network capabilities
Internet Protocol capabilities
Data network design
Telephony network design
General network management practices
Only authorized personnel should use the Access Concentrator system.
Chapter 1 Getting Started
Related Reading
1-2 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Related Reading
Lucent Technologies Information Products
Product Information Library
To install and use your AC 60, you will need to read the following publications, which are provided on your Lucent Technologies AC 60 Product Information Library CD-ROM.
To configure the I/O and server modules, read the following publications that are provided on your Lucent Technologies Access Concentrator Modules Product Information Library CD-ROM.
To configure the Connection Gateway API, read the following publications that are provided on your Lucent Technologies Access Concentrator Modules Product Information Library CD-ROM.
Table 1-1. PacketStar Modules Product Information Library (Adobe Acrobat
Reader Files) Release 6.3.0
Menu Option Document
PacketStar PSAX Modules
Alarm Module Guide
Channelized DS3 Module Guide
Channelized STS-1e Module Guide
DS1 IMA Module Guide
DS3 ATM Module Guide
DS3 Frame Relay Module Guide
DS3 IMA Module Guide
DSP2A/ DSP2B/ DSP2C Voice Server Modules Guide
E1 IMA Module Guide
E3 ATM Module Guide
Enhanced DS1 Module Guide
Enhanced E1 Module Guide
Ethernet Module Guide
High-Density E1 (21-port) Module Guide
High-Speed Module Guide
Medium-Density DS1 Module Guide
Multi-Serial Module Guide
OC-3c Multi-Mode and Single-Mode 1+1 APS Module Guide
OC-3c Multi-Mode and Single-Mode Modules Guide
255-700-025 1-3
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Chapter 1 Getting Started
Related Reading
Route Server Module Guide
STM-1 Multi-Mode and Single-Mode 1+1 MSP Module Guide
STM-1 Multi-Mode and Single-Mode Modules Guide
Tones and Announcements Server Module Guide
Voice 2-Wire Station Module Guide
Voice 2-Wire Office Module Guide
Release Notes and Bulletins
Access Concentrator Family Release Notes, Release
6.3, Issue 1
New Features Bulletin for Release 6.3
Voice 2-Wire Office Module Safety Bulletin, Issue 1
Safety Warnings Shipping Sheet, Issue 4
Application Notes
PacketStar PSAX Access Concentrators Caller ID Application Note, R6.3
Declarations of Conformity
I/O Module 32 MB Memory Upgrade, Declaration of Conformity, EMC
Route Server Module, EMC
DSP2 Voice Server Module with Echo Cancellation, EMC
DSP2A Voice Server Module with Echo Cancellation, EMC
DSP2B Voice Server Module with Echo Cancellation, EMC
DSP2C Voice Server Module with Echo Cancellation, EMC
High-Density E1 Module, EMC
High-Density E1 Module, Telecom,
High-Density E1 Module, Low Voltage,
Other Hardware Installation Guides
PacketStar PSAX CO Access Concentrators, Patch Panel and Cable Installation Guide, Issue 1
Table 1-1. PacketStar Modules Product Information Library (Adobe Acrobat
Reader Files) Release 6.3.0
Menu Option Document
Chapter 1 Getting Started
Related Reading
1-4 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Printed Documents For your convenience, the following documents from your Product
Information Library CD-ROM are also available in printed form. For ordering information, contact your Lucent Technologies distributor or account representative.
Table 1-2. PacketStar Release 6.3.0 Product Information Library (Printed
Documents)
Document Issue COMCODE
Document
Number
AC 60 Installation and Operation Guide, Release 6.3
Issue 1 300303005 255-700-056
AC 60 User Guide, Release 6.3 Issue 1 300303021 255-700-025
PacketStar Connection Gateway API Developer’s Guide, Release 6.3.0
Issue 1 300314515 255-700-100
Using the PacketStar PSAX Access Concentrator Caller ID Feature Appli­cation Note
Issue 1 300284338 255-700-006
PacketStar ATM Access Concentra­tors and DEFINITY ECS Application Note
Issue 1 300306065 255-700-122
PacketStar ATM Access Concentra­tors Trunk Conditioning Application Note
Issue 1 300287018 255-700-072
Connecting a CBX or GC Switch to a PacketStar PSAX Access Concentra­tor Via an ATM Port Application Note
Issue 1 300287059 255-700-012
Table 1-3. PacketStar™ Modules Product Information Library (Printed
Documents)
Document Issue COMCODE
Document
Number
Alarm Module User Guide, Release
6.3
Issue 1 300303062 255-700-027
Channelized DS3 Module User Guide, Release 6.3
Issue 1 300303070 255-700-028
Channelized STS-1e T1 Module User Guide, Release 6.3
Issue 1 300303088 255-700-029
255-700-025 1-5
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Chapter 1 Getting Started
Related Reading
DS1 IMA Module User Guide, Release
6.3
Issue 1 300303096 255-700-032
DS3 ATM Module User Guide, Release
6.3
Issue 1 300303104 255-700-033
DS3 Frame Relay Module User Guide, Release 6.3
Issue 1 300303112 255-700-034
DSP2A, DSP2B and DSP2C Voice Server Modules User Guide, Release
6.3
Issue 1 300303120 255-700-035
E1 IMA Module User Guide, Release
6.3
Issue 1 300303138 255-700-036
E3 ATM Module User Guide, Release
6.3
Issue 1 300303146 255-700-037
Enhanced DS1 Module User Guide, Release 6.3
Issue 1 300303161 255-700-038
Enhanced E1 Module User Guide, Release 6.3
Issue 1 300303161 255-700-039
Ethernet Module User Guide, Release
6.3
Issue 1 300303179 255-700-040
High-Density E1 Module User Guide, Release 6.3
Issue 1 300303187 255-700-073
High-Speed Module User Guide, Release 6.3
Issue 1 300303195 255-700-041
Medium-Density DS1 Module User Guide, Release 6.3
Issue 1 300298676 255-700-120
Multi-Serial Module User Guide, Release 6.3
Issue 1 300303203 255-700-042
OC-3c Multi-Mode and Single- Mode 1+1 APS Modules User Guide, Release
6.3
Issue 1 300303211 255-700-043
OC-3c Multi-Mode and Single-Mode Modules User Guide, Release 6.3
Issue 1 300303229 255-700-044
Route Server Module User Guide, Release 6.3
Issue 2 300303328 255-700-052
STM-1 Multi-Mode and Single-Mode 1+1 MSP Modules User Guide, Release 6.3
Issue 1 300303336 255-700-046
Table 1-3. PacketStar™ Modules Product Information Library (Printed
Documents)
Document Issue COMCODE
Document
Number
Chapter 1 Getting Started
Related Reading
1-6 255-700-025
PacketStar Access Concentrator 60 User Guide, Issue 1 Release 6.3.0
Other Publications
Numerous books are currently available on the subject of basic telecommunications technology and specific protocols. In addition to such general reading, you should also be familiar with the specifications identified in the following documents:
American National Standards Institute (ANSI) documents
~ T1.207, Operations, Administration, Maintenance, and Provisioning
(OAM&P) Terminating Test Line Capabilities and Access Arrangements
~ T1.403, af-phy-0016.000 and af-test-0037.000 ~ T1.646, Broadband ISDN-Physical Layer Specification for UNI Including
DS1/ATM
ATM Forum Technical Committee Specifications:
~ Circuit Emulation Service Interoperability Specification Version 2.0,
af-vtoa-0078.000
~ Specifications of (DBCES) Dynamic Bandwidth Utilization, af-vtoa-0085.000 ~ Integrated Local Management Interface Specification Version 4.0,
af-ilmi-0065.000
~ Interim Inter-switch Signaling Protocol (IISP) Specification Version 1.0,
af-pnni-0026.000
~ Private Network-Network Interface (PNNI 1.0) Specification Version 1.0,
af-pnni-0055.000
~ Private Network-Network Interface (PNNI 1.0) Specification Version 1.0
Addendum, af-pnni-0066.000
~ Private Network-Network Interface (PNNI 1.0) Specification Version 1.0 Errata
and PICS, af-pnni-0081.000
~ Traffic Management Specification Version 4.1, af-tm-0121.000 ~ User to Network Interface (UNI) Specification Version 3.0
STM-1 Multi-Mode and Single-Mode Modules User Guide, Release 6.3
Issue 1 300303344 255-700-045
Tones and Announcements Server Module User Guide, Release 6.3
Issue 1 300303427 255-700-121
Voice 2-Wire Office Module User Guide, Release 6.3
Issue 1 300303351 255-700-047
Voice 2-Wire Station Module User Guide, Release 6.3
Issue 1 300303377 255-700-048
Table 1-3. PacketStar™ Modules Product Information Library (Printed
Documents)
Document Issue COMCODE
Document
Number
Loading...