This material is protected by the c opyrig ht laws of the Uni ted States a nd oth er coun tries. It may no t be r eproduc ed, dist ribut ed, or a ltere d
in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements,
contracts, or licensing, without the express written consent of Lucent Technologies. For permission to reproduce or distribute, please email
your request to techcomm@lucent.com.
Notice
Every effort was made to ensure that the information in this document was complete and accurate at the time of printing, but information is
subject to change.
European Community (EC) RTTE Compliance
Hereby, Lucent Technologies, declares that the equipment documented in this publication is in compliance with the essential
requirements and other relevant provisions of the Radio and Telecommunications Technical Equipment (RTTE)
Directive 1999/5/EC.
To view the official Declaration of Conformity cert ificate for this equipment, according to EN 45014, access the Lucent IN S online
documentation library at http://www.lucent.com/ins/doclibrary/.
Safety, Compliance, and Warranty Information
Before handling any Lucent Acces s Networks hardware product, read th e Edge Access Safety and Compl iance Guide included in your
product package. See that guide also to determine how products comply with the electromagnetic interference (EMI) and network
compatibility requireme nts of your cou ntry. See the warranty card includ ed in your produ ct package for the limited warranty that Lucent
Technologies provides for its products.
Security Statement
In rare instances, unauthorized individuals make connections to the telecommunications network through the use of access features.
Trademarks
Lucent, the Lucent logo, and all Lu cent brand and product names are tr ademarks or registered tra demarks of Lucent Technologies Inc.
Other brand and product names are tradem a rks of th ei r respe ctive holders.
Ordering Information
You can order the most up- to-date product information and computer-based trainin g online at http://www.lucent.com/ins/
bookstore.
Feedback
Lucent Technologies appreciates customer comments about this manual. Please send them to techcomm@lucent.com.
Lucent Technologies
Customer Service
Product and service information, and software u pgrades , ar e available 2 4 h ours a day.
Technical assistance options accommodate varying levels of urgency.
Finding information and software
To obtain software upgrades, release notes, and addenda for these products, log in to
Lucent OnLine Customer Support at http://www.lucent.com/support.
Lucent OnLine Customer Support also provides technical information, product
information, and descriptions of available services. Th e center is open 24 hours a day,
seven days a week. Log in and select a service.
Obtaining technical assistance
Lucent OnLine Customer Support at http://www.lucent.com/support
provides easy access to technical support. You can obtain technical assistance through
email or the Internet, or by telephone. If you need assistance, make s ure that you have
the following information available:
•Active service or maintenance contract number, entitlement ID, or site ID
•Product name, model, and serial number
•Software version or release number
•Software and hardware options
•If supplied by your carrier, service profile identifiers (SPIDs) associated with
your line
•Your local telephone company’s switch type and operating mode, such as AT&T
5ESS Custom or Northern Telecom Natio nal ISDN-1
•Whether you are routing or bridging with your Lucent product
•Type of computer you are using
•Description of the problem
Customer Service
CellPipe™ 20 Series User’s Guideiii
Customer Service
Obtaining assistance through email or the Internet
If your services agreement allows, you can communicate directly with a technical
engineer through Email Technical Support or a Live Chat. Select one of these sites
when you log in to http://www.lucent.com/support.
Calling the technical assistance center (TAC)
If you cannot find an answer through the tools and informati on of
Customer Support
OnLine Customer Support
Contact Us
Alternatively, call 1-866-LUCENT8 (1-866-582-3688) from any location in North
America for a menu of Lucent services. Or call +1 510-769-6001 for an operator. If
you do not have an active services agreement or contract, you will be charged for
time and materials.
or if you have a very urgent need, contact TAC. Access
at
http://www.lucent.com/support
for a list of telephone numbers inside and outside the United States.
Lucent OnLine
Lucent
and click
ivCellPipe™ 20 Series User’s Guide
Contents
Customer Service ..................................................................................................... iii
This document is a combined user’s guide for the CellPipe™ 20 Series Product
Family. The products currently addressed by this guide include the following:
•CellPipe 20A-GX, supporting software version 1.65LU
•CellPipe 20S, supporting software version 1.51LU
The contents of this guide include basic information about the aforementioned units,
such as standard features, setup instructions, and inf ormation on ho w to configure and
administer the units. This guide is written primarily to provide information for
network administrators responsible for configuring and administering the units and
secondarily to acquaint users with the functionalities of the units.
1
For additional support, you can also visit the
http://www.lucent.com/support
most current release notes for this product family.
CellPipe™ 20 Series User’s Guide1-1
Lucent OnLine Customer Support at
to download software upgrades and the
Introduction
What is the CellPipe 20 Series Product Family?
What is the CellPipe 20 Series Product Family?
The current CellPipe 20 Series Product Family consists of two groups of
products—symmetrical digital subscriber line (SDSL) and asymmetrical digital
subscriber line (ADSL)—for Point-to-Point Protocol (PPP) or Frame Relay over
asynchronous transfer mode (ATM). All units support IP bridging and routing.
See Table 1-1 for a summary of the features for each product.
Table 1-1. CellPipe 20 Series products
CellPipe unitsDescription
CellPipe 20A-GXSupport for:
•ADSL Annex A mode operation
•G.Lite interface
•DMT line code
•IP routing and bridging, PPP support
•Asymmetrical transmission with downstream
rates of 64Kbps to 8Mbps and upstream rates of
64Kbps to 1Mbps
•One 10BaseT Ethernet port
•Eight PVCs in bridging mode
•Five PVCs in routing mode
CellPipe 20SSupport for:
•SDSL transmission
•IP routing and bridging, PPP support
•2B1Q line code
•Symmetrical transmission rates in the range of
144Kbps to 2.32Mbps
•Integrated four-por t 10BaseT Et hern et hub
•Eight PVCs in bridging mode
•Five PVCs in routing mode
1-2CellPipe™ 20 Series User’s Guide
Lucent TURN-UP
The CellPipe 20 Series Product Family supports the Lucent TURN-UP™ automated
CPE provisioning system. TURN-Up is enabled when a user powers up his unit and
allows service providers to quickly and efficiently distribute and provision CPE gear
without the use of truck-rolls. Furthermore, TURN-UP stores configuration
information on a central server , making co nfiguration man agement ef fi cient and easy.
Introduction
Lucent TURN-UP
!
Caution: If you attempt to manually configure the unit, TURN-UP will be disabled.
To re-enable TURN-UP, you need to select the default command and reinstall the
factory default configuration.
CellPipe 20 Series management
CellPipe 20 Series units can be managed via three different connections:
•Console port
•Ethernet po rt
•WAN port
CellPipe 20 series units are managed through a command-line interface (CLI). Also,
rudimentary management can be accomplished with SNMP. You set up a connection
between your computer and the device and use VT100 emulation software to display
and change configuration information. See Chapter 3, “Command-Line Interface,”
for a description of all the commands in the command-line interface.
Prior to setting up your unit, verify the contents of the package for your unit against
the package-contents list provided in this chapter. After determining the contents are
complete, connect the cables, verify all status lights are operating properly, and
establish a serial connection from you computer to the unit.
V erifying package contents
Verify the contents of the CellPipe 20 Series package you receive.
The CellPipe 20 Series package contains the following items:
•CellPipe unit
•10BaseT Ethernet cable (yellow)
•WAN cable with RJ11 connector (blue)
2
CellPipe™ 20 Series User’s Guide2-1
Setup
Items you need for installation
•Power supply
•Warranty card
Note: All CellPipe units are shipped w it h a po we r s upp ly. However, European users
need to purchase an additional wall-outlet cab le because of reg ional variations in wall
outlets. Please check with your sales representative for the item specific to your unit.
Figure 2-1. Power supplies
U.S., Asia, Australia
power supply
European
power supply
Items you need for installation
In addition to the items provided with your CellPipe unit, you will also need the
following item:
•An ethernet network interface card (NIC) for your PC
Connecting CellPipe 20 Series products
Figure 2-2 on page 2-3 shows the rear panel for each model. There are many
similarities between the units and the procedure for connecting the units are quite
similar as well.
2-2CellPipe™ 20 Series User’s Guide
Connecting CellPipe 20 Series products
Figure 2-2. CellPipe 20 Series rear panels
CellPipe 20A-GX
CellPipe 20S
To connect up the CellPipe 20 Series units, proceed as follows:
1LAN connections:
•On the CellPipe 20A-GX, use the provided Ethernet cable (yellow) to
connect the ETHERNET port to the NIC on a computer or to an appropriate
networking component.
•On the CellPipe 20S, use the provided Ethernet cables to connect the four
LAN ports (1X, 2X, 3X, 4X ) to NICs on computers or to appropriat e
networking components.
2WAN connections:
•Use the blue WAN cable to connect the WAN port to a wall xDSL connector
set up by your service provider.
3Connect the power cable and power up the unit.
Setup
Note: Apply power last. Doing so turns on the unit, which does not have a power
switch.
CellPipe™ 20 Series User’s Guide2-3
Setup
Checking status lights
Checking status lights
Observe the activity pattern of the lights at the front of the CellPipe units to verify that
they are connected properly.
Figure 2-3. Status lights
When all the cables are connected, verify that:
•The pwr light comes on initially and remains on. If not on, make sure the power
supply is properly connected.
•The act light blinks during any LAN traffic. Otherwise it remains off.
•The lnk light is on if there is an Ethernet connection established. If not on,
check to make sure your Ethernet cable is properly connected.
•The wan light blinks until a connection is established and then it remains on.
•The con light is on only during the unit self-test.
Console setup
You need to set up a serial connection between the unit and your computer to access
the command-line interface and configure a CellPipe 20 Series unit.
You need a 9-pin RS-232 serial cable to connect to the CellPipe unit through the
console port.
You also need a terminal emulation program, such as HyperTerminal, PROCOMM
PLUS, Zterm, or any other program that supports VT100 ter minal emu lation, to open
a session directly with the unit.
2-4CellPipe™ 20 Series User’s Guide
Setup
Console setup
Set your communications software to connect with the following settings:
•Connection—Specify a direct connection from the unit to the computer.
•Serial port—Specify the serial port on the computer the software is to use.
•Terminal type—SpecifyVT100.
•Duplex—Specify Full. This is the default for most communications software.
•Bits per second—Specify 9600.
•Data bits—Specify 8.
•Parity—Specify None.
•Stop bits—Specify 1.
•Flow control—Specify None.
A >> prompt appears when the connection is completed.
CellPipe™ 20 Series User’s Guide2-5
Loading...
+ 33 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.