LSC LIGHTING
SYSTEMS
(AUST) PTY LTD
Bldg 3, 66-74 Micro
Circuit
South Dandenong VIC
Australia 3175
T +61 (0)3 9702 8000
F +61 (0)3 9702 8466
INSTALLATIONS
Version 1.1
August 2012

EKO Installations
Our Ref: p:\eko\consultant specs\eko installation photo concepts v1.1.doc
24 x EKO 524/R
24 x 20A channels with RCD on the input to each group of 12 channels
This EKO dimmer installation shows the retrofit to TCN 9s existing dimmer room, re-using
existing cabling systems.
o Existing cabling was carefully removed and left in place whilst the analogue dimmers
were removed.
o A unistrut framework was utilised to mount the EKO installation frame, to which the
existing cabling was re-terminated and tested.
o The wall frame was then sheeted out with plasterboard, set, skimmed and painted.
o The electronics cabinets were hung, mains inputs and data cabling terminated and the
dimmers configured and commissioned using the front panel touch screens menus.
TCN 9 Sydney
As Installed Installation Frames

EKO Installations
Our Ref: p:\eko\consultant specs\eko installation photo concepts v1.1.doc
8 x EKO 524/R
24 x 20A channels with RCD on the input to each group of 12 channels
3 x EKO 612/R
6 x 25A channels with RCD on the input to each group of 12 channels
This EKO dimmer installation shows a new dimmer installation to QTQ 9.
o EKO installation frames were surface mounted to the new wall surfaces.
o Cabling was brought through apertures, tested and terminated.
o The electronics cabinets were hung, mains inputs and data cabling terminated and the
dimmers configured and commissioned using the front panel touch screens menus.
QTQ 9 Brisbane
As Installed Installation Frames

EKO Installations
Our Ref: p:\eko\consultant specs\eko installation photo concepts v1.1.doc
Mackay Entertainment and Convention Centre
As Installed Installation Frames

EKO Installations
Our Ref: p:\eko\consultant specs\eko installation photo concepts v1.1.doc
6 x EKO 524LRC
24 x 20A channels with RCD on each individual output channel.
This EKO dimmer installation shows a new dimmer installation to the Mackay Entertainment and
Convention Centre.
o Cable tray installed
o EKO installation frames surface mounted.
o Cabling installed on trays, tested and terminated.
o The electronics cabinets were hung, mains inputs and data cabling terminated and the
dimmers configured and commissioned using the front panel touch screens menus.
Contractor: Barcam Commercial 5 Hodges St. Mackay, QLD 4740 Phone (07) 4957-2831
Mackay Entertainment and Convention Centre

EKO Installations
Our Ref: p:\eko\consultant specs\eko installation photo concepts v1.1.doc
21 x EKO 324/M/B & 1 x EKO 312/M/B
24 x 10A & 12 x 10A channels respectively with RCBO on each output channel, delivering
“dimmer per outlet”, eliminating the requirement for a patch panel. System has TRUpower
dimming or clean mains power per channel, selectable at the front touch screen. All dimmers
are monitored and configured using Houston Show Config software on a network of 584
channels though out the Centre.
This EKO dimmer installation shows a completely new dimmer installation to the Gold Coast Arts
Centre Theatre.
o Cable tray installed
o EKO installation frames surface mounted.
o Cabling installed on trays, tested and terminated.
o Load wiring to all 528 distributed outlets.
o The electronics cabinets were hung, mains inputs and data cabling terminated and the
dimmers configured and commissioned using the front panel touch screens menus.
Contractor: I & R Electrical Pty Ltd, PO Box 682 Ashmore City 4214, irelectric@aanet.com.au
Ph 0411876898
Gold Coast Arts Centre

EKO Installations
Our Ref: p:\eko\consultant specs\eko installation photo concepts v1.1.doc
Gold Coast Arts Centre

EKO Installations
Our Ref: p:\eko\consultant specs\eko installation photo concepts v1.1.doc
Gold Coast Arts Centre