Lowrance X-5 User Manual

INSTALLATION AND OPERATION MANUAL
X-5
LCG
RECORDER
LITHO USA
988-0105-02
LOWRANCE
A2000
E.
SKELLY
DR., TULSA,
OKLA. 74128
INC.
PDF compression, OCR, web-optimization with CVISION's PdfCompressor
NOTES
45
PDF compression, OCR, web-optimization with CVISION's PdfCompressor
TABLE OF CONTENTS
NOTES lnstaUation
Connections
Power
Temperature Noise
Keyboard Operation
On Off 2nd Clear Auto
Sensitivity Sensitivity—Automatic Sensitivity—Manual
(3RAYLINE
Chart
Speed
Scale Markers
Range
Lower Limit—Automatic Lower Limit—Manual
Limit
Upper
Auto
Range
Digital 10th
Alarms
Zone Alarm
Clearing
Note
Depth Light
Discirniination
Temperature
Surface Speed
Log
Feet Fathoms,
Pulse Preset
Display Memory Command
FASTRAJc
Grayline Speaker
Clear Distance
Zone Alarm
Key
Alarm
Clarity
Checkerboard/Lines
Volume
Narrow/Wide Auto
Digital Averaging Battery Backup
Scale On/Off Calibrate Test Pattern Keel Offset Total Transducers and Cone
Signal Interpretation Fish
Surveying
Bait Fish
Speed
System
Signals
How to Obtain Service How to Obtain a Schematic
.. .. . . . .. .
. . . . ... . . . ... .
.
Sensor Installation
Basics
with Zoom Bottom Track
Control
(SCC)
Meters
Key—MENUS
Log
Reset
Range
Angles
Window.
a Lake
. .........
.. . . . .. . ... . ..... 1
4 5 6 8 8 8 8 9 9 9
10 10
11
12 13 14 14 15 15 16 17 18 19 20
21 21 21
23 23 24 25 26 27 27 28 28 29 30
31
32 32 32 32 33 33 33 33 34 35 36
36 37
38 40
40
41 41
PDF compression, OCR, web-optimization with CVISION's PdfCompressor
44
The Lowrance X-5
cated and reliable instrument of its kind. Its
the
sharpest
the "ON" button
enables sonars.
To
where it
the road. After the
rest of this manual in detail. The more
water,
definition ever. This unit is so
and let it do all the work.
to
you
open
started with
get
all
begins,
you've
the more
your
Liquid Crystal
a whole world of features not available in other
up
X-5,
your
and
improper
read
these instructions
will
X-5
do for
Sonar
However,
first read the installation section. This is
installation can cause
you
you.
INSTALLATION
Mounting
The X-5 can be installed in
clearance when tilted for
allow wood screw or
to aluminum
a
piece
mounting attach the
panels
of
plywood
hardware. Make certain there is
and transducer cables.
power
the best
through
with sheet metal screws.
on the back of thin
A one inch hole in the base of the
and
transducer cables to be routed
the cables have been
adhesive
(RN)
to
routed,
prevent
water leaks.
convenient
any
viewing angle.
bolt
mounting.
fiberglass panels
enough
gimbal
up through
the hole can be filled with silicone
is the most
(LCG)
resolution
high
advanced,
and
know when
you
taking
installed
location,
Holes in the bracket base
provided
sophisti-
display gives
can
just
manual control
problems
your
you get
press
down
X-5,
to the
there is
read
The bracket can be attached
However,
we
suggest placing
to secure the
room
behind the unit to
bracket allows the
the
mounting
power
surface. After
rubber
NOTES
Power
be attached to an
electrical boat's
battery.
and black other has a connector for
sensor. See the owner's manual enclosed with installation instructions.
Connections
The
X-5
operates
interference
engine
The
or an
power
ground
from a 12 volt
accessory
accessory
or
(random
cable has two
wires for
connection to the 12 volt
the
battery system.
buss,
power
but if
The
you
have
power
problems
cable can
dots or lines that show whenever the
is
then attach the cable
on),
sets of cables. One set has the red
temperature probe
and the
the LSS-5
2
directly
battery system.
optional speed
sensor for
speed
with
to the
power
The
43
PDF compression, OCR, web-optimization with CVISION's PdfCompressor
NOTES
The
negative supplied
with the battery
#18
power power
accidental reversed.
applied.)
crimp
or
gauge
source
cable and
power
or
ground.
cable has
two
wires,
An in-line fuse
with the X-5. This attaches
connector.
accessory
wire onto it. Be certain
(battery
your
polarity
(However,
The other end of the fuse holder attaches
buss. If the cable
that the fuse holder is as close
or
accessory buss)
X-5 in the event
reversals
and will not be harmed if the wires
the unit will not
red is the holder
containing
positive
lead and
a 4
to the red wire on the
is not
long enough,
as
possible.
of a short. The X-5 is
splice ordinary
This
protected
work until the correct
black is
fuse is
amp
power
to the
protects
polarity
cable
to the
the
from
are
is
-Power CQbe
Sptke
Figure
PDF compression, OCR, web-optimization with CVISION's PdfCompressor
42
1 Ten-ç
Sarsor
3
TEMPERATURE
The
contact with
location. Once a two #8 stainless steel connector to X-5's
the X-5's
temperature
the
See
temperature
power
speed
figure
the water at all times. The
suitable
pass through.
cable.
Plug
cable.
power
sensor into the
sensor's
plug
3 for details.
SENSOR INSTALLATION
sensor should be mounted in a location that
diagram
is
place
screws. Above the water line drill a ¾"
the
NOTE: If the
to the in-line
found,
Route the cable via the shortest
sensor's cable into the in-line connector on
speed
sensor's in-line
speed
connector on the X-S's
in
mount the sensor to the hull with
sensor is also
Figure
TEMPERATURE SENSOR
2 shows a
Figure
installed, plug
connector,
2
hole for the
path
then attach
power
allows typical
to the
the
cable.
HOW TO OBTAIN SERVICE
If
have a
you
before
help
Assistance can often be extended
problem
sending
one of our Authorized Service Centers or
Department
If
live in the state of
you
Please detail the
ment
If
instructions.
SCHEMATIC
Should
send promptly.
rance sonar unit
in
Tulsa,
live out of the state of
you
be able to save
may
it's determined
DIAGRAM AND
desire a schematic and
you
to the
$1.00
Be sure to
address below and the information will
it in for
with
repair
your
sonar
by telephone
OK.
Oklahoma,
Oklahoma, problem you
you
your
call collect 918-437-6881.
are
the
inconvenience of
unit must be
experiencing.
returned,
PARTS LIST
parts
include the model and serial number of
unit, please
us a chance to
give
or
letter Write or call
the Lowrance Customer Service
call
1-800-331-3889,
Our
returning your
we'll
provide
list for
your
Lowrance
be mailed to
Service
full
your
free. If
Depart-
unit.
shipping
sonar,
you
Low-
api
Figure
Mail To: Lowrance
12000 E.
Tulsa,
Electronics
Skelly
Oklahoma
Dr.
74128
SPECIFICATIONS
3
Dimensions
Weight Transmitter
Output Receiver
Operating Operating Voltage
Number of Pixels
Power
Sensitivity
Current
(typical)
pounds
watts
375
watts
90db
500 ma 9-15
vdc
192 vertical
64
horizontal
total
12,288
(peak
(RMS)
to
peak)
S?eed
StnSbv.
41
PDF compression, OCR, web-optimization with CVISION's PdfCompressor
Loading...
+ 14 hidden pages