Louroe Electronics TLSP-F User Manual

MODEL TLSP-F/TLSP-S
®
6955 VALJEAN AVE, VAN NUYS, CA 91406
PH: (818)994-6498 / FAX: (818)994-6458
/ www.louroe.comtechsupport@louroe.com
SPEAKER/MICROPHONE
INSTALLATION AND OPERATING INSTRUCTIONS
MODEL TLSP-F
MODEL TLSP-S
INTRODUCTION
Model TLSP is a two-way talk/listen vandal resistant speaker/microphone, designed for correctional facilities or areas of high vandalism. When functioning as part of a Louroe Audio Monitoring System, Model TLSP provides two-way talk/listen capabilities between the remote area (jail cells, etc) and the Louroe Base Station. The unit consists of an electret condenser microphone and a 3” speaker fitted to a special tone path and mounted to an 11 gauge stainless steel face plate. The tone path positioning protects the microphone and speaker from vandalism. Included with Model TLSP is a 6”x6”x4” back box and security hardware.
Model TLSP-F is for flush mounting to a ceiling or wall Model TLSP-S is for surface mounting to a ceiling or wall
TLSP-F Faceplate is 7”x7” TLSP-S Faceplate is 6”x6”
Back Box for both units is 6”x6”x4”
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
Page 1 of 4
(818)
tlsp_inst_3/15
INSTALLATION AND OPERATING INSTRUCTIONS
WIRING CONNECTIONS FOR TLSP MICROPHONE AND SPEAKER
MICROPHONE AND SPEAKER
Microphone Connections
Located behind the speaker portion of TLSP is a PC board with a small terminal block marked A, B, C. Using shielded portion of recommended wiring: 1) RED wire goes to terminal A (12 Vdc supply)
2) Black wire goes to terminal B (audio output)
3) Bare wire (drain) goes to terminal C (ground)
Speaker Connections
Mounted next to speaker is a 70V transformer with two lead wires GREEN (positive) and WHITE (ground). Using wire nuts, connect these two wires to the unshielded GREEN and WHITE cables of recommended wiring (West Penn 356 or equivalent)
CONNECTING MODEL TLSP-F / TLSP-W TO A LOUROE BASE STATION
The following procedure pertains to all Louroe Base Stations with talkback
After wiring connections are made at Model TLSP, run recommended 4 conductor cable to the Louroe Base Station and connect as follows. Connections are located at rear panel of the base station.
1) RED wire (12Vdc) goes to terminal “A” of Base Station (zone 1)
2) BLACK wire (Audio Output) goes to terminal “B” of Base Station (zone 1)
3) BARE wire (ground) goes to terminal “C” of Base Station (zone 1)
4) GREEN speaker wire goes to “TB” (talkback) terminal of Base Station (zone 1)
5) WHITE speaker wire goes to “G” (ground) terminal of Base Station (zone 1) Repeat same procedure for the remaining zones
SPECIFICATIONS (Model TLSP-F and TLSP-S)
Output of microphone (Mic)
Frequency Response (Mic) Current Drain (mic)
Speaker
Faceplate (TLSP-S)
Faceplate (TLSP-F)
Backbox
Weight
Shipping Weight
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
Line Level (0 dB, 600W @ 1KW) 40 Hz to 15 kHz 10 mA 3”, 2W w/ 70V transformer
6”L x 6”W
7”L x 7”W
6”H x 6”W x 4”D
4 lbs
7 lbs
Page 2 of 4
Vandal Resistant Stainless Steel
(818)
tlsp_inst_3/15
WIRING DIAGRAM FOR MODEL TLSP-F / TLSP-S
SPEAKER WIRE (NEGATIVE)
SPEAKER WIRE (POSITIVE)
GREEN
WIRE NUT
GREEN
INSTALLATION AND OPERATING INSTRUCTIONS
SPEAKER/MICROPHONE
REAR OF TLSP SPEAKER/MICROPHONE
TRANSFORMER (70V)
WHITE
RED BLACK
WHITE
BARE
A B C
Terminal Block Identification Microphone A - 12Vdc (red) B - Audio Output (black) C - Ground (bare)
Green wire (positive) White wire (negative) are speaker connections
NOTE: WHEN USING CABLE FROM OTHER
MANUFACTURERS, COLOR CODE MAY VARY
TO LOUROE
BASE STATION
REFER TO PAGE 1
DIAGRAM OR TO THE SPECIFIC
BASE STATION INSTALLATION
INSTRUCTIONS FOR CONNECTIONS
WIRING REQUIREMENTS
4 Conductor consisting of:
+
2 Conductor shielded, 20 gauge with 22 gauge drain (microphone connection)
+
2 Conductor unshielded, 18 gauge
(speaker connection)
All in the same jacket
West Penn 356 or equivalent
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
Page 3 of 4
(818)
tlsp_inst_3/15
INSTALLATION AND OPERATING INSTRUCTIONS
MANUFACTURED
IN THE
IMPORTANT NOTICE
When this equipment is used as part of an audio monitoring system, the law requires that the public be given notice of AUDIO MONITORING ON THE PREMISES. A deca l noti ce is includ ed with each microphone shipped.
Federal Law References: Federal Regulations, US Code, Title 18. Crime and Criminal Procedure, Sec 2510.
LOUROE ELECTRONICS warrants that at the time of shipment products manufactured by LOUROE ELECTRONICS to be free of defects in material and workmanship. Should a defect appear within one year (12 months) from date of shipment, LOUROE ELECTRONICS will, at its sole discretion, repair or replace the defective equipment. This equipment shall not be accepted for repair or return without prior notification by LOUROE ELECTRONICS .
This warranty does not extend to any Louroe product that has been subjected to improper or incorrect installation, misuse, accident, or in violation of installation instructions provided by LOUROE ELECTRONICS.
Returned shipments to LOUROE ELECTRONICS shall be at customer’s expense. LOUROE ELECTRONICS will return the equipment prepaid via best way.
®
®
®
WARRANTY
AUDIO
MONITORING
On
These Premises
®
®
®
®
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
(818)
website: www.louroe.com e-mail: sales@louroe.com
Page 4 of 4
tlsp_inst_3/15