![](/html/32/32c1/32c1fd09003c42757581e725a37c6f2a231a788f654cdd27adcbc77e24a5afbf/bg1.png)
92 Series - FM - 2/4/6 Function combined Receiver/Actuator with Standard Transmitter
SYSTEM PART NUMBERS
92 1 50 2 Function Receiver/Actuator + 2 Function Standard Transmitter
92 1 54 4 Function Receiver/Actuator + 4 Function Standard Transmitter
92 1 56 6 Function Receiver/Actuator + 6 Function Standard Transmitter
REPLACEMENT TRANSMITTERS
92 1 02TX 2 Function Standard Transmitter
92 1 04TX 4 Function Standard Transmitter
92 1 06TX 6 Function Standard Transmitter
Part Number 92 1 54 shown, 92 1 50 and 92 1 56 are similar, the number of functions vary.
FEATURES
Soft-Start - a flow control valve in the supply line allows adjustment of the air supply into cylinder, hence the speed at which it moves.
This gives a degree of "feel" to the system when "inching" equipment, without restricting the exhaust flow from the cylinder but also
allowing immediate shut off.
Manual over-ride - this is available at all times. At rest, both pipes to the cylinder are "open to atmosphere", allowing for free movement
of the piston, with return to centre when the system is deactivated.
ENCL
OSURE
Lid Smoke PVC - to view LEDs
Base Black PVC
Breather Gortex fitted in base
Vent Sintered brass vent
Mounting 4 external lugs
Fixings 5mm (3/16”) not supplied
Lodar, 12189 State Highway 148 S, Henrietta, Texas. 76265 – Tel: 1 877 257 1581 – Fax: 1 763 431 2520
![](/html/32/32c1/32c1fd09003c42757581e725a37c6f2a231a788f654cdd27adcbc77e24a5afbf/bg2.png)
THE ACTUA TO
Chassis
Support Channel across vehicle
Bracket
Control Rod
Control rod setup on a popular carrier showing
air cylinder in an ideal mounting position
Simple to fit
One weld and one bracket
Cylinder
Control Lever
Housing
Weld
Simple to pipe
P
ush fit pipes to cylinder - colour coded
Connect blue pipe to the air suppl
SPECIFICATIONS
The Actuator Assembly
Air Cylinder(s) 32mm(1.25") bore x 50mm(2") stroke
Fitted with trunnion and clevis, with lug(s) ready for welding
2 push fit elbows per cylinder
The Receiver/Control Box
Radio Receiver with outputs to valves - prewired
Flow control valve
3ft lengths of output pipe with push fit connections to the cylinder(s) - colour coded for each pair of functions.
6ft length blue supply pipe fitted with 1/4" adaptor (push fit)
8ft twin core power supply cable
Max air pressure 120psi
Air requirements Must be CLEAN and DRY (air flow is minimal)
Max push 149 lbs @120psi
Max pull 128 lbs @120psi
Voltage 12 and 24 Volts available (24 Volt systems are suffixed 24 – e.g. 92 1 50/24 etc)
WILL IT FIT
Trunnion fo
cylinder mounting
Allow
a minimum of 6mm (1/4”) clearance over dimensions shown
IMPORTANT MEASUREMENT when mounting
270mm (10.6”) approx with Cylinder at mid point
FOR RADIO SPECIFICATION SEE – s92 1 04 and s92 1 06
325mm (12.8”) approx at Max Travel
Control Lever
64mm
(2.5”)
approx
Lug for clevis
at cylinder rod end
Lodar, 12189 State Highway 148 S, Henrietta, Texas. 76265 – Tel: 1 877 257 1581 – Fax: 1 763 431 2520