Lodar 2 Function User Manual

Page 1
w92100.09
2 Function with Standard Transmitter
SYSTEM PART NUMBER
92100 2 Function Receiver + 2 Function Standard Transmitter.
No Master
REPLACEMENT TRANSMITTER
REPLACEMENT RECEIVER
9200RX - 2 Function Receiver – No Master
TRANSMITTER SPECIFICATION
ENCLOSURE
Material Glass reinforced Nylon Switch Type 12mm Dome Switch Functions 2 Identification Pockets for printed text or image insertion
RF
Modulation 2-GFSK. Gaussian Frequency Shift Keying Frequency 433.050 MHz to 434.790 MHz Channels 1 Channel Selection Fixed Technology Hand-held Transmitter
Temperature Range -10o C to + 40o C (13o F to + 104
o
F). Use Lithium for lower temperatures Range 60m (200ft) Aerial Internal – printed on PCB Transmitted power 1mW Typical
POWER
Batteries 1x 9V Alkaline Manganese Quiescent Current 15µA Current Transmitting 20mA
PROTECTION
IP Rating 54 Registration codes Over 16 million
INDICATOR
Type 1 x Red LED Off Transmitter is OFF and in standby mode Slow flash Transmitter is ON and ready for use (The SET Button has been pressed and released) On Transmitting (A STOP, SET or Function Button is being pressed) Fast flash Transmitting – Indication that the battery will need replacing soon
COMPLIANCE
FCC FCC CFR 47-part 15.231
433.9MHz IC ISED RSS-210 Issue 8
433.9MHz RoHS Directive 2011/65/EU
CONTENTS
1 x Receiver 1 x Standard Transmitter 1 x Lanyard 1 x Cover 1 x Instructions
Page 2
w92100.09
RECEIVER SPECIFICATION
ELECTRICAL
Voltage Nominal 12/24V DC Voltage Min/Max 8 to 36V DC Switch Type MOSFET (Positive Switching)
RF
Modulation 2-GFSK. Gaussian Frequency Shift Keying Frequency 433.050 MHz to 434.790 MHz
902.025 MHz– 927.975 MHz Channels 32 Channel Selection Fixed Channel hopping Technology Fixed Receiver
Temperature Range -40o C to + 70o C (-40o F to + 158
o
F)
Range 60m (200ft)
CURRENT CAPACITY
FET Rating 10A System Rating 10A Quiescent Current 31mA 12V/ 17mA 24V on Standby (Not SET) Overload Protection 10A (Auto Shutdown)
AERIAL
Internal Antenna Yes Supplied and fitted External Antenna Optional AC9860/ AC9861/ AC9862/ AC9863 & AC9869 – order separately
OUTPUTS
Master No Function 2 Supply to Receiver is switched
CONFIGURATION
RS232 Programming Yes For programming interlocks, push/push latch, parallel master inhibit, timeout, channel timeout delay, to users requirements master on delay, radio button de-latching and output allocation.
PERFORMANCE
Simultaneous Outputs Yes Programable (Modify through configuration) Instant TX response Yes Programable (Modify through configuration)
DIAGNOSTICS
LED’s Yes Confirm 5 Volts, SET, Fault and all Outputs.
PROTECTION
Back EMF Yes Diode protection on all outputs Registration codes Yes Over 16 million STOP Connection Yes Internal Emergency Stop Connection
WIRING
Wiring Loom Yes 3 metres (10ft) supplied and fitted Cable Gland Yes Supplied and fitted Connections Screw terminal into plug and socket on PCB, for easy swap out
Page 3
w92100.09
ENCLOSURE
Weight 0.3 lbs (335gms) Lid Clear PC/FR V0 and UV stabilised Base Black PC V0 and UV stabilised Breather Gortex fitted in base Mounting 4 external lugs Fixings 5mm (3/16) not supplied IP Rating IP55
92 Series
92000
92002
92004
92100
92102
92104
BUILD SPECIFICATION TABLE FOR MODELS IN
THIS RANGE
Ident
Legend
Connection
+ - F1 F2
Positive, Negative, F1 and F2
S S S S S S
F3 F4 M
F3, F4, and Master
M S M S
ST -
STOP and -
S S S S
S+ S-
S+ S- S
S S S
ANT
Internal Antenna
S S S S S S
SMA
Connector (external antenna)
S S S S LK1 P Master - Parallel
C C C C LK2 C Master – Continuous
C C C C LK3
RS232
RS232 S
S S S
3 metres 4 core
S S
3 metres 7 core
S S S S
9801 Lo-Cover
S S
S
S = Standard. M = Standard but Master only connected. C = Customer configured (see Factory Settings).
+ Positive 8-36V supply
- Negative 0 Volts F1 to F4 Outputs to F1 through F4 M Master Output STOP - STOP, when grounded shuts down the Receiver S+ S- Master Secondary for Safety solenoid connections etc. ANT Blade connector for internal antenna SMA Aerial connection for optional external antenna (internal antenna must be removed) LK1 Master Selection by Jumper (Parallel) LK2 Master Selection by Jumper (Continuous) Factory Settings 418/915MHz configured Parallel, 433.92MHz configured Continuous RS232 RS232 for Wired Remote and interface to access special programmes
Page 4
w92100.09
COMPLIANCE
REG 10 EC Type-approval mark E11 037601
EC Type-approval No: e11/72/245*2009/19*7601*00
FCC FCC CFR 47 Part 15.109
433.050MHz to 434.790MHz
FCC CFR 47 Part 15.109
902.025MHz to 927.975MHz IC ICES-003 Issue 6.
433.050MHz to 434.790MHz
ICES-003 Issue 6.
902.025MHz to 927.975MHz
CE RED Directive
ETSI EN 300 220-2 v3.2.
ETSI EN 300 220-1 v3.1.1.
ETSI EN 301 489-17 V3.1.1, ETSI EN 301 489-1 V2.1.1
433.050MHz to 434.790MHz
Australia/NZ ETSI EN 300 220-2 v3.2.1
ETSI EN 301 489-1 V2.1.1
433.050MHz to 434.790MHz
915.025MHz to 927.975MHz RoHS Directive 2011/65/EU
Photo of PCB
Connector Side Component Side
Loading...