Lochinvar PNA251-080 User Manual

Charger Power DV Commercial Gas Water Heaters
Power Direct Vent Water Heaters
Ideal for restaurants, commercial kitchens retrofit and replacement applications.
Standard Features
Independent PVC Venting - The stand alone vent exhausts
Glass-Lined Steel Tank – 300 PSI test pressure, 150 PSI
working pressure.
Magnesium Tank Saver Anode – Large diameter anode rod
for longer tank life and greater protection.
Electronic Ignition – Spark-to-pilot ignition system
eliminates the need for a continuously burning pilot light, which saves energy, by providing pilot gas only when the system calls for heat.
Approved for Operation at 180°F Outlet Temperature.
Temperature & Pressure Relief Valve – Factory installed.
Brass Drain Valve
Handhole Cleanout – Provides easy access.
Dielectric Fittings – Factory installed and designed to
provide additional protection for longer tank life.
Automatic Induced-Draft Blower – Provides balanced flue
operation for direct vent applications.
Non-CFC Foam Insulation – Meets ASHRAE standby
loss requirements.
CSA International Design Certified
Warranty – 3 year limited tank warranty; 1 year limited
warranty on parts. (See warranty for details)
Options
ASME Tank Construction
(250,000 Btu/hr model only)
NSF Construction
Low NOx Construction
Charger Power DV Commercial Water Heater Dimensions
Model Tank Gal. Btu/hr GPH @ Vent Water Connections Shipping
Number Const. Cap. Input 100°F Rise A D E F Size Top Front Rear Weight
PNR150-080 STD 80 150,000 145 63-1/2” 68-1/4” 51-1/4” 20-3/4” 3” 1-1/2“ 1-1/2” 2” 645 PNR150-100 STD 100 150,000 145 72” 77-1/4” 60-1/4” 20-3/4” 3” 1-1/2” 1-1/2” 2” 735 PNR200-080 STD 80 199,999 194 63-1/2” 68-1/4” 51-1/4” 20-3/4” 3” 1-1/2“ 1-1/2” 2” 645 PNR200-100 STD 100 199,999 194 72” 77-1/4” 60-1/4” 20-3/4” 3” 1-1/2“ 1-1/2” 2” 735 PNR250-080 STD 80 250,000 242 63-1/2” 73” 51-1/4” 20-3/4” 4” 1-1/2“ 1-1/2” 2” 645 PNR250-100 STD 100 250,000 242 72” 82” 60-1/4” 20-3/4” 4” 1-1/2“ 1-1/2” 2” 735 PNA251-080 ASME 80 250,000 242 63-1/2” 73” 51-1/4” 20-3/4” 4” 1-1/2“ 1-1/2” 2” 720 PNA251-100 ASME 100 250,000 242 72” 82” 60-1/4” 20-3/4” 4” 1-1/2“ 1-1/2” 2” 815
Notes: Change 'N' to 'L' to denote LP models. Gas Connections are 3/4"
115 Volt AC required
FOR EASE IN ORDERING
BY MODEL NUMBER
P N R 200 100
POWER
DIRECT VENT
CONSTRUCTION
Btu/hr INPUT
This heater is a 199,999 Btu/hr
input, Natural gas Charger Power
Direct Vent, water heater with a
100 gallon storage capacity
2/08-Printed in U.S.A.
Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000
www.Lochinvar.com
PNR-01
(Replaces PGR-01 2/06)
NAT. GAS
GALLON
CAPACITY