DXS-54/EC
DON'T POINT AT HEAT SOURCES
(HEATERS, ETC.), WINDOWS, OTHER
MOTION DETECTORS OR DOOR/WINDOW
TRANSMITTERS
BEDROOM
BATH
KITCHEN
FRONT
ROOM
(FOR INDOOR
USE ONLY)
MOUNT
DETECTOR
SO THAT
INTRUDER
WILL CROSS
BEAMS
MOTION
DETECTOR
SUPERVISED
WIRELESS
MOTION
DETECTOR
Installation Instructions
(760) 438-7000 • FAX (760) 438-7043
www.linearcorp.com
DXS-54/EC FEATURES DETECTION PATTERN TYPICAL INSTALLATION
MOTION
DETECTOR
LENS
BY
TEST INDICATOR
BEHIND LENS
(BLINKS DURING
WALK TEST, FLASHES
WHEN BATTERY IS LOW
DURING MOTION)
WALK
TEST
BUTTON
The DXS-54/EC is a battery powered passive infrared motion detector
PRODUCT DESCRIPTION
with a built-in transmitter designed for use with Linear’s DXS and DX
format receivers. This transmitter can be used in a variety of motion
detection applications. When the passive infrared sensor detects
motion in its field of view, the transmitter sends a digitally coded
wireless signal to its companion receiver.
The digital DXS code format features over a million possible codes.
The DXS transmitters are precoded at the factory to unique codes, so
no field coding is required. The DXS-54/EC can send three different
signals: alarm, low battery and status.
For versatility, any transmitter can be programmed into any receiver
channel. Receivers must be programmed to the transmitter’s code
before system testing and operation. Refer to the receiver’s
instructions for details on programming.
In a typical installation, the motion detector is mounted indoors in a
corner or on a wall between six and eight feet high. The sensor will
monitor the infrared level in its detection pattern. If the level increases
or decreases rapidly (as when a person or animal moves through the
area) the transmitter triggers, sending an alarm signal to the receiver.
MOTION
DETECTOR
IN CORNER
9 METERS
9 METERS
DETECTION
AREA
TOP
VIEW
The unit is powered from a 9-Volt alkaline battery. The battery’s life
can be up to three years depending on the area’s traffic. When the
battery gets low, the test indicator will flash and a low battery signal
will be sent to the receiver when the detector senses motion.
Approximately every hour, the DXS-54/EC will send a status
transmission to the receiver. The hourly signal updates the receiver
to the transmitter’s condition. By monitoring status transmissions, the
receiver can determine if a transmitter has a low battery or has been
removed from the system. DXS format receivers can monitor status
signals, DX format receivers cannot.
To conserve battery life, during normal operation, the detector can
trigger the transmitter a maximum of once every four minutes.
For setup and testing, pressing the detector’s test button places the
unit in walk test mode for four minutes. The installer can walk in front
of the unit while viewing the red test indicator through the detector’s
lens to determine the detection area.
In walk test, an alarm signal is sent each time the walk test indicator
lights. During normal operation, the detector requires a “pulse count”
of three events in eight seconds before sending an alarm transmission.
CASE
LOCKING
SCREW
(ON BOTTOM)
CONNECTING BATTERY MOUNTING DETECTOR BASE WALK TEST
REMOVE
SCREW
AND OPEN
CASE
CONNECT 9-VOLT ALKALINE
BATTERY TO BATTERY CLIP
(PLUS SIDE UP)
NOTE: BE SURE TO
REPLACE THE CASE
SCREW AFTER CLOSING
THE CASE
PROGRAM RECEIVER AND TEST CHANGING BATTERY INTERNATIONAL WARRANTY
FOR PROGRAMMING,
REFER TO THE RECEIVER'S
INSTRUCTIONS
AFTER PROGRAMMING RECEIVER
TO THE TRANSMITTER'S CODE
TEST THE SYSTEM
STAYING CLEAR, WAIT AT LEAST
FIVE MINUTES BEFORE WALKING
INTO THE DETECTION AREA
WALK ACROSS THE DETECTION
PATTERN AND VERIFY THAT
THE RECEIVER ACTIVATES
OPERATING
TEMPERATURE
RANGE:
+32° TO +120° F
(0° TO +49° C)
2-3 METERS
9 METERS
MOUNTING THE DETECTOR
IN A CORNER IS PREFERRED
AFTER MOUNTING, SNAP
DETECTOR ONTO BASE
AND REPLACE CASE SCREW
USE CENTER
HOLES FOR
WALL
MOUNTING
PUNCH OUT REQUIRED HOLES
FOR SCREW MOUNTING
NOTE:
THE DETECTOR CAN
BE MOUNTED WITH
DOUBLE STICK TAPE,
BUT IS NOT ALLOWED
IN UL INSTALLATIONS
WHEN THE DETECTOR
HAS A LOW BATTERY:
REMOVE
SCREW
AND OPEN
CASE
REPLACE THE BATTERY WITH A FRESH
9-VOLT ALKALINE OR LITHIUM BATTERY
(PLUS SIDE UP)
USE ALKALINE OR
LITHIUM BATTERIES ONLY
SNAP DETECTOR ONTO BASE
AND REPLACE CASE SCREW
WHEN FINISHED
R&TTE VAEE 27807, EMC, SFT, ETS
Linear Corporation declares that the apparatus DXS-54/EC complies
with the essential requirements and other relevant provisions of
Directive 1995/5/EC.
USE SIDE HOLES
FOR CORNER
MOUNTING
SIDE
VIEW
MOUNT
DETECTOR
6-8 FEET
HIGH
PUSH
WALK
TEST
BUTTON
UNIT WILL STAY IN
WALK TEST MODE
FOR 4 MINUTES AFTER
PRESSING WALK TEST
BUTTON
VERIFY THAT DETECTION
PATTERN COVERS DESIRED
AREA
This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty
Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from
Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers.
Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no
obligations or liabilities on the part of Linear Corporation for consequential damages arising out of or in
connection with use or performance of this product or other indirect damages with respect to loss of property,
revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied
warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date
as labeled on the product. This Linear Corporation Warranty is in lieu of all other warranties express or implied.
For warranty service on Linear equipment return product, at sender’s expense to:
Linear Hong Kong 19/F Hounor Industrial Centre, 6 Sun Yip Street Chai Wan, Hong Kong
Attention: Repairs Department
REPAIRS POLICY
Charges will be made for equipment that is not in warranty, shows customer abuse, or is damaged by the effects of
lightning, water, fire, or other abnormal happenings.
Customer’s equipment sent in for repair may be repaired or replaced with new or remanufactured equipment at Linear’s
discretion.
The customer is always responsible for shipping and handling charges to the repairs facility. Linear will pay return
shipping and handling charges on “in warranty” products shipped back to the customer. The customer will be billed
for the return shipping and handling charges on “out of warranty” products.
There will be a 50% expedite fee for any express requ ests.
The International Sales Manager must be notified prior to the return of product to Linear. All international returns must
have an International Repair Authorization number (IRA#). The number must be marked on all packages. Failure to
do so will cause delays in processing.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need in portable wireless signaling.
However, there are some limitations which must be observed. The radios are required to comply with local rules and
regulations as radio devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that
occur on or near their operating frequencies, regardless of code settings. Changes or modifications to the device may
void regulatory compliance. Infrequently used radio links should be tested regularly to protect against undetected
interference or fault. A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale
distributor or dealer, and these facts should be communicated to the ultimate users.
Copyright © 2002 Linear Corporation 220133 A
WALK IN FRONT OF UNIT
WHILE WATCHING RED LIGHT
NOTE: AFTER INITIAL SETUP
WALK TEST UNIT ANNUALLY