Linear DXS-54 User Manual

DXS-54 Installation Instructions Linear P/N: 209509 B Material: 20 Lb. Mead Bond Size: 8 1/2" x 11" Ink: PMS 561 (Aqua) Scale: 1-1
SUPERVISED WIRELESS MOTION DETECTOR
Installation Instructions
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
PRODUCT DESCRIPTION
The DXS-54 is a battery powered passive infrared mot ion detector with a built-in transmitter designed for use with Linear’s DXS and DX format receivers. This transmitter can be used in a variety of motion detection applications. When the passive infrared sensor detects motion in its field of view, the transmitter sends a digitally coded wireless signal to its companion receiver.
The digital DXS code format features over a million possible codes. The DXS transmitters are precoded at the factory to unique codes, so no field coding is required. The DXS-54 can send three different signals: alarm, low battery and status.
For versatility,
any transmitter can be programmed into any receiver
channel.
Receivers must be programmed to the transmitters code before system testing and operation. Refer to the receiver’s instructions for details on programming.
In a typical installation, the motion detector is mounted indoors in a corner or on a wall between six and eight feet high. The sensor will monitor the infrared level in its detection pattern. If the level increases or decreases rapidly (as when a person or animal moves through the area) the transmitter triggers, sending an alarm signal to the receiver.
The unit is powered from a 9-Volt alkaline battery. The batterys life can be up to three years depending on the areas traffic. When the battery gets low, the test indicator will flash and a low battery signal will be sent to the receiver when the detector senses motion.
Approximately every hour, the DXS-54 will send a status transmission to the receiver. The hourly signal updates the receiver to the transmitters condition. By monitoring status transmissions, the receiver can determine if a transmitter has a low battery or has been removed from the system. DXS format receivers can monitor status signals, DX format receivers cannot.
To conserve battery life, during normal operation,
the detector can
trigger the transmitter a maximum of once every four minutes.
For setup and testing, pressing the detectors test button places the unit in walk test mode for four minutes. The installer can walk in front of the unit while viewing the red test indicator through the detector’s lens to determine the detection area.
In walk test, an alarm signal is sent each time the walk test indicator lights. During normal operation, the detector requires a pulse count of three events in eight seconds before sending an alarm transmission.
DXS-54 FEATURES DETECTION PATTERN TYPICAL INSTALLATION
CONNECTING BATTERY MOUNTING DETECTOR BASE WALK TEST
PROGRAM RECEIVER AND TEST CHANGING BATTERY LINEAR LIMITED WARRANTY
This Linear product is w arranted against defects in material and workmansh ip for twelve (12) months. The Warranty Expiration D ate is labeled on the product.
This warranty extends onl y to wholesale customers
who buy direct from L inear or through Linears norm al distribution chan nels.
Linear does not warrant
this product to consumers.
Consumers should inquire from their selling dealer as to the nature of the
dealers warranty, if any.
There are no obligations or liabilities on t he part of Linear corporation for consequential damages arisi ng out of or in connection with use or performance o f this product or other indirect damages w ith respect to loss of p roperty, revenue, or pro fit, or cost of removal, installation, or reinstallation.
All implied warranties, including implied warranties for merchantability and
implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product.
This
Linear Corporation Warranty is in lieu of all other warranties express or implied.
For warranty service on Linear equipment return product, at senders expense t o: All products returned fo r warranty service require a Return Produc t Authorization Number (RPA#). Contact Linear Technical Servi ces at 1-800-421-1587 for an RPA # and other important detail s.
IMPORTANT !!!
Linear radio controls prov ide a reliable communications link and fill an import ant need in portable wireless signalling. Howev er, there are some limit ations which must b e observed.
For U.S. install ations only: The radi os are required to comply w ith FCC Rules and Regul ations as Part 15 devices. As such, they have limi ted transmitter power and therefore limit ed range.
A receiver cannot respond to more than one transmit ted signal at a time and ma y be blocked by radio signals that oc cur on or near their operating f requencies, regardless of code settings.
Changes or modificati ons to the device may void FCC compliance.
Infrequently used radi o links should be tested regularly to protect against undetected int erference or fault.
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer , and these facts sho uld be communicated to the u ltimate users.
Copyright © 1997 Linear Corporation 209509 B
DXS
FORMAT
By
WALK TEST BUTTON
MOTION DETECTOR LENS
CASE LOCKING SCREW (ON BOTTOM)
TEST INDICATOR BEHIND LENS (BLINKS DURING WALK TEST, FLASHES WHEN BATTERY IS LOW DURING MOTION)
OPERATING TEMPERATURE RANGE: +32° TO +120° F (0° TO +49° C)
DETECTION
AREA
30 FEET
30 FEET
30 FEET
6-8 FEET
SIDE VIEW
TOP
VIEW
MOTION DETECTOR IN CORNER
DON'T POINT AT HEAT SOURCES (HEATERS, ETC.), WINDOWS, OTHER MOTION DETECTORS OR DOOR/WINDOW TRANSMITTERS
BEDROOM
BATH
KITCHEN
FRONT ROOM
(FOR INDOOR
USE ONLY)
MOUNT
DETECTOR
SO THAT
INTRUDER
WILL CROSS
BEAMS
MOTION DETECTOR
REMOVE SCREW AND OPEN CASE
CONNECT 9-VOLT ALKALINE BATTERY TO BATTERY CLIP (PLUS SIDE UP)
NOTE: BE SURE TO REPLACE THE CASE SCREW AFTER CLOSING THE CASE
PUNCH OUT REQUIRED HOLES FOR SCREW MOUNTING
USE CENTER
HOLES FOR
WALL
MOUNTING
USE SIDE HOLES
FOR CORNER
MOUNTING
NOTE:
THE DETECTOR CAN BE MOUNTED WITH DOUBLE STICK TAPE, BUT IS NOT ALLOWED IN UL INSTALLATIONS
MOUNT DETECTOR 6-8 FEET HIGH
MOUNTING THE DETECTOR IN A CORNER IS PREFERRED
AFTER MOUNTING, SNAP DETECTOR ONTO BASE AND REPLACE CASE SCREW
PUSH WALK TEST BUTTON
WALK IN FRONT OF UNIT WHILE WATCHING RED LIGHT
UNIT WILL STAY IN WALK TEST MODE FOR 4 MINUTES AFTER PRESSING WALK TEST BUTTON
VERIFY THAT DETECTION PATTERN COVERS DESIRED AREA
NOTE: AFTER INITIAL SETUP WALK TEST UNIT ANNUALLY
AFTER PROGRAMMING RECEIVER TO THE TRANSMITTER'S CODE TEST THE SYSTEM
STAYING CLEAR, WAIT AT LEAST FIVE MINUTES BEFORE WALKING INTO THE DETECTION AREA
WALK ACROSS THE DETECTION PATTERN AND VERIFY THAT THE RECEIVER ACTIVATES
FOR PROGRAMMING, REFER TO THE RECEIVER'S INSTRUCTIONS
REMOVE SCREW AND OPEN CASE
WHEN THE DETECTOR HAS A LOW BATTERY:
REPLACE THE BATTERY WITH A FRESH 9-VOLT ALKALINE OR LITHIUM BATTERY (PLUS SIDE UP)
USE ALKALINE OR LITHIUM BATTERIES ONLY
SNAP DETECTOR ONTO BASE AND REPLACE CASE SCREW WHEN FINISHED
Loading...