DXS-32/EC
MINIATURE 
SUPERVISED 
DOOR/WINDOW 
TRANSMITTER
Installation Instructions
(760) 438-7000 • FAX (760) 438-7043
www.linearcorp.com
DXS-32/EC FEATURES & ACCESSORIES OPENING CASE
TRANSMITTER
MAGNET
ALIGNMENT
MARKS
The DXS-32/EC is a battery powered stationary transmitter designed for use with Linear’s DXS and
PRODUCT DESCRIPTION
DX format receivers. This transmitter can be used in a variety of wireless remote control applications. 
Triggering the transmitter with its built-in magnetic switch sends a digitally coded wireless signal to
BY
MAGNET
SIDE
MARK
its companion receiver.
The digital DXS code format features over a million possible codes. The DXS transmitters are 
precoded at the factory to unique codes, so no field coding is required. The DXS-32/EC can send 
four different codes: alarm, restore, low battery and status.
Receivers must be programmed to the transmitter’s code before system testing and operation. Refer 
to the receiver’s instructions for details on programming.
In a typical installation, the magnet is mounted on a door or window and the transmitter is mounted 
on the frame. When the magnet moves more than 1 cm away from the transmitter, an alarm signal 
is sent. When the magnet returns next to the unit, a restore signal is sent. The magnet is adjustable 
with four height positions. A 0.5 cm high magnet spacer is also supplied to snap on to the base of 
the magnet.
The transmitter is powered from two 3-Volt #2032 lithium batteries with an expected battery life of 
up to 4 years. Every hour, the DXS-32/EC will send a status transmission to the receiver. The hourly 
signal updates the receiver to the transmitter’s condition. By monitoring status transmissions, the 
receiver can determine if a transmitter has a low battery or has been removed from the system. DXS 
format receivers can monitor status signals, DX format receivers cannot.
Normally, the transmitter sends an exit/entry delay transmission code. Cutting an internal jumper 
selects an instant transmission code. Cutting this jumper doesn’t change the time of the actual 
transmissions, but changes the code of the signal sent so the receiver can determine the transmitter’s 
function.
REMOVE THE CASE TOP BY TWISTING A 
SMALL FLAT BLADE SCREWDRIVER IN 
THE SLOT ON EITHER END OF THE TRANSMITTER
ADJUSTABLE
MAGNET
MAGNET
ALIGNMENT
TRANSMITTER
SCREWS AND
DOUBLE STICK TAPE
MAGNET
SCREWS AND
DOUBLE STICK TAPE
MAGNET CAN BE MOUNTED UP TO
1 cm FROM LEFT SIDE OF
TRANSMITTER
SQUEEZE MAGNET TABS TO
ADJUST MAGNET HEIGHT (4 POSITIONS)
MARKS
MAGNET
ADJUSTMENT
TAB (EACH SIDE)
TWIST
REMOVE BATTERY PROTECTION STRIP COMPONENT LOCATIONS
ANTENNA
TWO TYPE 2032 
BATTERIES
PULL OUT & DISCARD 
BATTERY PROTECTION 
STRIP TO ACTIVATE 
TRANSMITTER
DELAY/INSTANT JUMPER 
(CUT JUMPER FOR INSTANT)

LEFT OPENING DOOR
TRANSMITTER 
MOUNTED ON 
DOOR JAMB
(NOTE: SMALL END 
OF TRANSMITTER UP)
MAGNET 
MOUNTED 
ON DOOR
RIGHT OPENING DOOR
EXAMPLE INSTALLATIONS TRANSMITTER MOUNTING
SLIDING WINDOW
ATTACH BOTTOM CASE 
USING THE SCREWS OR
MAGNET MOUNTED 
ON WINDOW FRAME
DOUBLE-HUNG WINDOW
TRANSMITTER 
MOUNTED ON 
WINDOW SILL
DOUBLE-STICK TAPE PROVIDED
TRANSMITTER 
MOUNTED ON 
DOOR JAMB
(NOTE: SMALL END 
OF TRANSMITTER DOWN)
MAGNET MOUNTED 
ON DOOR
TRANSMITTER 
MOUNTED ON 
WINDOW FRAME
MAGNET 
MOUNTED 
ON WINDOW 
SASH STILE
ADJUSTING MAGNET HEIGHT PROGRAMMING RECEIVER
ADJUST MAGNET 
HEIGHT UNTIL 
CASE LEVELS 
ARE ABOUT EQUAL
MAGNET
THE SNAP-ON MAGNET SPACER 
CAN BE USED TO ADD 0.5 cm HEIGHT
TRANSMITTER
R&TTE VAEE 27836, EMC, SFT, ETS
Linear Corporation declares that the apparatus DXS-32/EC complies with the essential 
requirements and other relevant provisions of Directive 1995/5/EC.
TO THE MAGNET (SPACERS CAN ALSO 
BE SNAPPED TOGETHER FOR MORE LIFT)
NOTE: ATTACHING THE TRANSMITTER WITH DOUBLE-STICK
TAPE IS NOT ALLOWED IN UL INSTALLATIONS
PROGRAMMING:
1. PLACE RECEIVER INTO PROGRAM 
OR "LEARNING" MODE
2. ACTIVATE TRANSMITTER BY 
OPENING DOOR OR WINDOW
3. VERIFY THAT THE RECEIVER 
ACCEPTED THE SIGNAL
TESTING:
1. PLACE RECEIVER INTO TEST MODE
2. OPEN DOOR, VERIFY THAT THE 
RECEIVER INDICATES AN OPEN DOOR
OPEN 
DOOR
3. CLOSE DOOR, VERIFY THAT THE 
RECEIVER RECOGNIZED THAT THE 
DOOR IS CLOSED
CHANGING BATTERIES INTERNATIONAL WARRANTY
1
3 4
SLIDE OLD BATTERIES
OUT OF BATTERY
HOLDERS
INSERT TWO TYPE 2032 
BATTERIES 
PLUS (+) SIDE UP
INTO BATTERY HOLDERS
DISCARD OLD
2
BATTERIES 
PROPERLY
SEAT BATTERIES COMPLETELY 
INTO HOLDERS
BE SURE BATTERIES ARE 
NOT TOUCHING EACH 
OTHER
This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date 
is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s 
normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling 
dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear Corporation
for consequential damages arising out of or in connection with use or performance of this product or other indirect damages 
with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties,
including implied warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date as 
labeled on the product. This Linear Corporation Warranty is in lieu of all other warranties express or implied. 
For warranty service on Linear equipment return product, at sender’s expense to:
Linear Hong Kong 
19/F Hounor Industrial Centre 
6 Sun Yip Street 
Chai Wan, Hong Kong 
Attention: Repairs Department
REPAIRS POLICY
1 Charges will be made for equipment that is not in warranty, shows customer abuse, or is damaged by the effects of lightning,
water, fire, or other abnormal happenings.
1 Customer’s equipment sent in for repair may be repaired or replaced with new or remanufactured equipment at Linear’s
discretion.
1 The customer is always responsible for shipping and handling charges to the repairs facility. Linear will pay return shipping and
handling charges on “in warranty” products shipped back to the customer. The customer will be billed for the return shipping 
and handling charges on “out of warranty” products.
1 There will be a 50% expedite fee for any express requests. 
1 The International Sales Manager must be notified prior to the return of product to Linear. All international returns must have an
International Repair Authorization number (IRA#). The number must be marked on all packages. Failure to do so will cause 
delays in processing.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need in portable wireless signaling. However, there 
are some limitations which must be observed. 
1 The radios are required to comply with local rules and regulations as radio devices. As such, they have limited transmitter
power and therefore limited range.
1 A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or
near their operating frequencies, regardless of code settings. 
1 Changes or modifications to the device may void regulatory compliance. 
1 Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
Copyright © 2003 Linear Corporation 216304 B