Linear DXS-32 User Manual

INSTR,INSTL,DXS-32 LINEAR P/N: 216314 B MATERIAL: 20 LB. MEAD BOND SIZE: 8.500" X 11.000" INK: BLACK SCALE: 1-1 SIDE 1 OF 2
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
BY
MAGNET
SCREWS AND
DOUBLE STICK TAPE
ADJUSTABLE
MAGNET
SQUEEZE MAGNET TABS TO
ADJUST MAGNET HEIGHT (4 POSITIONS)
MAGNET
ADJUSTMENT
TAB (EACH SIDE)
TRANSMITTER SCREWS AND
DOUBLE STICK TAPE
MAGNET CAN BE MOUNTED UP TO
1/2" FROM LEFT SIDE OF
TRANSMITTER
MAGNET
SIDE
MARK
TRANSMITTER
MAGNET
ALIGNMENT
MARKS
MAGNET
ALIGNMENT
MARKS
REMOVE THE CASE TOP BY TWISTING A SMALL FLAT BLADE SCREWDRIVER IN THE SLOT ON EITHER END OF THE TRANSMITTER
TWIST
PULL OUT & DISCARD BATTERY PROTECTION STRIP TO ACTIVATE TRANSMITTER
TWO TYPE 2032 BATTERIES
ANTENNA
DELAY/INSTANT JUMPER (CUT JUMPER FOR INSTANT)
INSTR,INSTL,DXS-32 LINEAR P/N: 216314 B MATERIAL: 20 LB. MEAD BOND SIZE: 8.500" X 11.000" INK: BLACK SCALE: 1-1 SIDE 2 OF 2
TRANSMITTER MOUNTED ON DOOR JAMB
(NOTE: SMALL END OF TRANSMITTER UP)
(NOTE: SMALL END OF TRANSMITTER DOWN)
MAGNET MOUNTED ON DOOR
MAGNET MOUNTED ON DOOR
TRANSMITTER MOUNTED ON WINDOW SILL
MAGNET MOUNTED ON WINDOW FRAME
SLIDING WINDOW
LEFT OPENING DOOR
RIGHT OPENING DOOR
TRANSMITTER MOUNTED ON DOOR JAMB
TRANSMITTER MOUNTED ON WINDOW FRAME
MAGNET MOUNTED ON WINDOW SASH STILE
DOUBLE-HUNG WINDOW
ATTACH BOTTOM CASE USING THE SCREWS OR DOUBLE-STICK TAPE PROVIDED
NOTE: ATTACHING THE TRANSMITTER WITH DOUBLE-STICK
TAPE IS NOT ALLOWED IN UL INSTALLATIONS
ADJUST MAGNET HEIGHT UNTIL CASE LEVELS ARE ABOUT EQUAL
TRANSMITTER
MAGNET
THE SNAP-ON MAGNET SPACER CAN BE USED TO ADD 1/4" HEIGHT TO THE MAGNET (SPACERS CAN ALSO BE SNAPPED TOGETHER FOR MORE LIFT)
PROGRAMMING:
1. PLACE RECEIVER INTO PROGRAM OR "LEARNING" MODE
2. ACTIVATE TRANSMITTER BY OPENING DOOR OR WINDOW
3. VERIFY THAT THE RECEIVER ACCEPTED THE SIGNAL
TESTING:
1. PLACE RECEIVER INTO TEST MODE
2. OPEN DOOR, VERIFY THAT THE RECEIVER INDICATES AN OPEN DOOR
3. CLOSE DOOR, VERIFY THAT THE RECEIVER RECOGNIZED THAT THE DOOR IS CLOSED
OPEN
DOOR
1
SLIDE OLD BATTERIES
OUT OF BATTERY
HOLDERS
2
3 4
DISCARD OLD BATTERIES PROPERLY
INSERT TWO DURACELL DL2032 BATTERIES
PLUS (+) SIDE UP
INTO BATTERY HOLDERS
SEAT BATTERIES COMPLETELY INTO HOLDERS
BE SURE BATTERIES ARE NOT TOUCHING EACH OTHER
Loading...