Control Panel Interface Series
The Partitioner 262B Door-Gard is a self-
262B Door-Gard Self-Contained Two Zone C ontrol
contained two-zone control system. A Form-C
alarm relay ties in easily to any standard
alarm zone creating an independent subsystem. The Partitioner is the perfect choice
for office suites, apartments, strip malls or
any place individual zone control is desired.
• 16 User Codes (arm/disarm or arm only)
• Keypad Programmable
• Non-Volatile EEPROM Memory
• Programmable Entry/Exit Delay Periods
• Form-C 1 Amp Alarm Relay
• Built-In Siren Driver
• Pre-Alarm Sounder
• Perimeter Zone
• Interior Zone
• At Home Arming
• Unique Touch Shunt Mode
• Programmable Alarm Recycle Time
• Programmable Panic
• Loop Status and Armed LED’s
• Contemporary Plastic Housing
• Alarm Memory by Zone
• Keypad Backlighting
System Defaults
The Partitioner is designed for e a sy installation in a minimum
amount of time. The following de fault values are factory
programmed:
Exit Delay 60 seconds
Perimeter Entry Delay (Zone 1) 30 seconds
Interior Entry Delay (Zone 2) 30 seconds
Alarm Recycle Time 3 minutes
Panic Input Off
Audible Key Press On
Relay State (when not in alarm) Energized (supervised)
Upon alarm condition, the relay changes state and the siren
driver output energizes.
If it is necessary to change any of these default values, please
refer to the Programming Options Chart after you are familiar
with the programming section.
Document #: 6062130 Rev 2.0
The Partitioner
Memory
Non-Volatile EEPROM memory means programmed
information won’t be lost if power is removed.
Programming
All programming is accomplished e ntire ly from the front of
the keypad. LED guidance makes programming easy and
changing codes takes a matter of seconds for an authorized
user.
Codes
The Partitioner allows up to 16 valid ind ividual user codes.
Codes can be from 1 to 6 digits in length and digits can be
repeated.
Arming Interlock
The Partitioner cannot be armed if a zone is unsafe (open).
The sounder signals three short beeps to indicate this
condition.
At Home Arming
When At Home Arming is activated, the interior zone (zone 2)
is automatically shunted. At Home Arming is activated by
pressing the # key within 5 seconds of a rming. At Home
Arming is ind icated by bo t h red and green LED’s light ing
when the systems are armed.
Touch Shunt
The perimeter zone (zone 1) can be shunted by pressing and
holding any key while the Partitioner is armed. If the key is
released while the perimeter zone is violated, the Partitioner
triggers the alarm instantly, bypassing the entry delay.
Alarm Memory/Loop Status
Pressing and holding the 1 or 2 keys for 2 seconds indicates
the current status and memory of the corresponding zone (1 =
zone 1 and 2 = zone 2). The sounder beeps twice to
acknowledge a key hold d own. The red LED lights if an
alarm has occurred on that zone. The green LED lights if the
zone is closed. Alarm memory is cleared by pressing and
holding the 0 until the sounder beeps twice. Alarm memory
can only be indicated when the Partitioner is disarmed.
Panic
The Partitioner has the ability to trigger an instant alarm when
the * and # keys are pressed simultaneously. Panic operates
regardless of whether or not the Partitioner is armed. Panic
triggers both the alarm and siren driver. This feature is
defaulted to off from the factory, but can be turned on through
the Programming Options Chart. Panic is reset by entering a
valid arm/disarm code.
Getting Started
LED Indications
Programm in g User C od es
1
1. Close perimeter loop (zone 1).
2. Close interior loop (zone 2).
3. Connect the positive (+) lead of your 12
4. Connect the negative (-) lead of your 12
5. Turn on your power supply. The
6. Enter Self-Test Mode by pressing
7. Open each loop one at a time. The
8. Once you’ve verified proper operation,
Note: You can program the keypad in
your shop or at the installation site.
Programmed information is stored in nonvolatile memory and won’t be lost if
power is removed.
Testing the System
Volt DC power supply to the terminal
strip (TS1) +V input on the Partitioner.
Volt DC power supply to the terminal
strip (TS1) -V input on the Partitioner.
Partitioner flashes all LED’s for 2
seconds, then enter normal operating
mode.
7890#123456*. The LED’s light
sequentially and the keypad is now in
Self-Test Mode.
sounder sounds continuously as long as
loop is open. Close each loop after
testing.
press any key to exit Self-Test Mode.
Green LED: Loop Status
On = Loops closed (safe to arm)
Off = Loop(s) open (won’t arm)
Red LED: Armed/Alarm Memory
On = System Armed
Off = System Disarmed
Flashing = System is (or was) in alarm
Red and Green LED’s Together
On = System Armed (At Home Mode)
Yellow LED
Rapid Flash = Entry Delay Warning
Note: The yellow Led is also used during
program mode.
Document #: 6062130 Rev 2.0
Operation Yellow LED
1. Enter Programming Mode
Press 99# (master code)*2 Flashes Slow
2. Change Master Code3
Press 1# (enter master code)* Flashes Fast
Press (enter master code)* Flashes Slow
3. Add/Change Second Code
Press 2# (enter user code)* Flashes Fast
Press (enter user code)* Flashes Slow
4. Add Change Third Code
Press 3# (enter user code)* Flashes Fast
Press (enter user code)* Flashes Slow
5. You can add up to 16 codes in this fashion.
6. Exit Programming Mode
Press * Off
1
Codes can be 1 to 6 digits in length.
2
The master code is defaulted to 1234 and allows
access to progra mming mode.
3
The master code is always user #1.
Notes:
If the master code is forgotten or does not work,
momentarily press the SW1 programming
switch to enter program mode. SW1 is located
on the front of the circuit board below the S1
keypad connector and can be accessed by
removing the keypad from the front. DO NOT
REMOVE THE KEYPAD RIBBON CABLE.
If the red LED turns on during programming
mode, a programming error has occurred.
Press * to clear the error and continue
programming.