Linear 262B Owner's Manual

Control Panel Interface Series
The Partitioner 262B Door-Gard is a self-

262B Door-Gard Self-Contained Two Zone C ontrol

contained two-zone control system. A Form-C alarm relay ties in easily to any standard alarm zone creating an independent sub­system. The Partitioner is the perfect choice for office suites, apartments, strip malls or any place individual zone control is desired.
16 User Codes (arm/disarm or arm only)
Keypad Programmable
Non-Volatile EEPROM Memory
Form-C 1 Amp Alarm Relay
Built-In Siren Driver
Pre-Alarm Sounder
Perimeter Zone
Interior Zone
At Home Arming
Unique Touch Shunt Mode
Programmable Alarm Recycle Time
Programmable Panic
Loop Status and Armed LED’s
Contemporary Plastic Housing
Alarm Memory by Zone
Keypad Backlighting

System Defaults

The Partitioner is designed for e a sy installation in a minimum amount of time. The following de fault values are factory programmed:
Exit Delay 60 seconds Perimeter Entry Delay (Zone 1) 30 seconds Interior Entry Delay (Zone 2) 30 seconds Alarm Recycle Time 3 minutes Panic Input Off Audible Key Press On Relay State (when not in alarm) Energized (supervised)
Upon alarm condition, the relay changes state and the siren driver output energizes.
If it is necessary to change any of these default values, please refer to the Programming Options Chart after you are familiar with the programming section.
Document #: 6062130 Rev 2.0
The Partitioner

Memory

Non-Volatile EEPROM memory means programmed information won’t be lost if power is removed.
Programming
All programming is accomplished e ntire ly from the front of the keypad. LED guidance makes programming easy and changing codes takes a matter of seconds for an authorized user.
Codes
The Partitioner allows up to 16 valid ind ividual user codes. Codes can be from 1 to 6 digits in length and digits can be repeated.
Arming Interlock
The Partitioner cannot be armed if a zone is unsafe (open). The sounder signals three short beeps to indicate this condition.
At Home Arming
When At Home Arming is activated, the interior zone (zone 2) is automatically shunted. At Home Arming is activated by pressing the # key within 5 seconds of a rming. At Home Arming is ind icated by bo t h red and green LED’s light ing when the systems are armed.
Touch Shunt
The perimeter zone (zone 1) can be shunted by pressing and holding any key while the Partitioner is armed. If the key is released while the perimeter zone is violated, the Partitioner triggers the alarm instantly, bypassing the entry delay.
Alarm Memory/Loop Status
Pressing and holding the 1 or 2 keys for 2 seconds indicates the current status and memory of the corresponding zone (1 = zone 1 and 2 = zone 2). The sounder beeps twice to acknowledge a key hold d own. The red LED lights if an alarm has occurred on that zone. The green LED lights if the zone is closed. Alarm memory is cleared by pressing and holding the 0 until the sounder beeps twice. Alarm memory can only be indicated when the Partitioner is disarmed.
Panic
The Partitioner has the ability to trigger an instant alarm when the * and # keys are pressed simultaneously. Panic operates regardless of whether or not the Partitioner is armed. Panic triggers both the alarm and siren driver. This feature is defaulted to off from the factory, but can be turned on through the Programming Options Chart. Panic is reset by entering a valid arm/disarm code.

Getting Started

LED Indications

Programm in g User C od es
1

1. Close perimeter loop (zone 1).
2. Close interior loop (zone 2).
3. Connect the positive (+) lead of your 12
4. Connect the negative (-) lead of your 12
5. Turn on your power supply. The
6. Enter Self-Test Mode by pressing
7. Open each loop one at a time. The
8. Once you’ve verified proper operation,
Note: You can program the keypad in your shop or at the installation site. Programmed information is stored in non­volatile memory and won’t be lost if power is removed.

Testing the System

Volt DC power supply to the terminal strip (TS1) +V input on the Partitioner.
Volt DC power supply to the terminal strip (TS1) -V input on the Partitioner.
Partitioner flashes all LED’s for 2 seconds, then enter normal operating mode.
7890#123456*. The LED’s light sequentially and the keypad is now in Self-Test Mode.
sounder sounds continuously as long as loop is open. Close each loop after testing.
press any key to exit Self-Test Mode.

Green LED: Loop Status

On = Loops closed (safe to arm) Off = Loop(s) open (won’t arm)

Red LED: Armed/Alarm Memory

On = System Armed Off = System Disarmed Flashing = System is (or was) in alarm

Red and Green LED’s Together

On = System Armed (At Home Mode)

Yellow LED

Rapid Flash = Entry Delay Warning
Note: The yellow Led is also used during program mode.
Document #: 6062130 Rev 2.0
Operation Yellow LED
1. Enter Programming Mode
Press 99# (master code)*2 Flashes Slow
2. Change Master Code3
Press 1# (enter master code)* Flashes Fast Press (enter master code)* Flashes Slow
3. Add/Change Second Code
Press 2# (enter user code)* Flashes Fast Press (enter user code)* Flashes Slow
4. Add Change Third Code
Press 3# (enter user code)* Flashes Fast Press (enter user code)* Flashes Slow
5. You can add up to 16 codes in this fashion.
6. Exit Programming Mode
Press * Off
1
Codes can be 1 to 6 digits in length.
2
The master code is defaulted to 1234 and allows
access to progra mming mode.
3
The master code is always user #1.
Notes:
If the master code is forgotten or does not work, momentarily press the SW1 programming switch to enter program mode. SW1 is located on the front of the circuit board below the S1 keypad connector and can be accessed by removing the keypad from the front. DO NOT REMOVE THE KEYPAD RIBBON CABLE.
If the red LED turns on during programming mode, a programming error has occurred. Press * to clear the error and continue programming.