232iLM Keypad Installation and Programming Instructions
Note: This product is designed to be installed and serviced b y security and lock industry professionals.
Specifications
Case Dimensions:
1
6
/2”L x 13/4”W x 11/8”D
Electrical:
Voltage: 5-12VDC (reader)
12-24VAC/DC (controller)
Current (max): 120mA
Relay Contacts:
Main Relay (controller): 2A
Aux Relays (controller): 1A
Bell Relay:
Form A; 1 Amp @ 30VDC;
500mA @ 125VAC
Environmental:
-20 º F to 130° F
Description:
Features
● Vandal Resist ant Case
● Sealed for Indoor or Outdoor Applications
● LED's for Relay Status Indication
● Bell Output
● Surface Mount
● Illuminated Hardened Keys
● Rated for Greater than One Million Key Cycles
Applications
● Low to Medium/Heavy Traffic Areas
● Rough Service Environments
● Mullion Frame Mounting
● Dimly Lit Areas
Wire Harness Configuration:
The 232iLM Access Control unit consists of two pieces: an
SSWiLM keypad front end and a 232 Access Control
Module. IEI's Door-Gard Series SSWiLM keypad combines
elegant looks with a mullion mount design in a rugged,
vandal resistant case, which you can use for almost any
application. The SSWiLM has hardened backlit keys
designed to perform in medium to high traffic areas and in
rough duty environments. The electronics are also
conformal coated, which makes the keypad suitable for
indoor or outdoor applications.
Basic Operation:
To gain access through the door enter your code (1-6 digits)
followed by the * key on the keypad.
Packing List:
(1) SSWiLM Keypad
(1) IEI 232 Controller
(1) Eight-Conductor Wire Harness
(4) Three-Conductor Wire Harness
(1) Controller Hardware Pack
(1) Mullion Hardware Pack
5
(1)
/64” Allen Wrench
(1) Anti-Oxidant Grease Pack
(1) Installation/Programming Manual
(1) Self-Contained Access Control Programming Guide
Pin Wire Color Signal Name
1 Red Power (+)
2 Black Power (-)
3 White/Black Data 0
4 White/Yellow Data 1
5 Blue Not Used
6 Brown Not Used
7 White Bell Relay Contact (A)
8 White Bell Relay Contact (B)
Wiring Requirements:
18 AWG – 1000 Ft.
20 AWG – 500 Ft.
22 AWG – 250 Ft.
Document # 6050800 Rev 1.1 1 of 12 www.ieib.com
Keypad Installation Procedure:
Step 1: Drill through the back plate using a 11/64” bit. Use the template on the back page to accurately mark the mounting
holes before drilling. Then drill the mounting holes with a
9
/64” drill bit. Also drill the hole for the wires. This may
vary depending on the number of co nductors required.
Step 2: On the keypad end, strip back the insulator from the wire and tape the drain wire (shield) to the jacket. Now
connect the required wires to the 8-conductor wire harness provided. The wire harness plugs into the 8-position
connector on the keypad. At the other end of your wire run, strip back the insulator from the wire but do not
the drain wire to the jacket. The drain wire must
be connected to ground at the controller end. See the diagrams
tape
below.
Step 3: Finally mount the SSWiLM keypad onto the mounting surface using the provided screws. Do no over-tighten the
screws, which may result in damage.
Wiring the SSWiLM to an IEI 232 Access Control Module
The connection between the SSWiLM and the 232 Controller requires a 4-conductor, stranded wire with overall foil shield.
The 8-conductor wire harness from the keypad connects to connector P6 on the controller. Connect the wires, color to
color (red to red, black to black, white/black to white/black and white/yellow to white/yellow). Refer to the wire lengths on
the first page. As mentioned above, the drain wire must be attached to Ground on the controller si de, which is the Vterminal or negative of your power supply.
Document # 6050800 Rev 1.1 2 of 12 www.ieib.com
Basic Access Control Using an Electromagnetic Lock (Maglock)
IEI recommends a
filtered and regulated
DC power supply.
If you aren't using door
contacts you must short
the white/orange and
white wires
Basic Access Control Using an Electric Door Strike
IEI recommends a
filtered and regulated
DC power supply.
If you aren't using door
contacts you must short
the white/orange and
white wires
Document # 6050800 Rev 1.1 3 of 12 www.ieib.com
Integrated Access Control Wiring
IEI recommends a
filtered and regulated
DC power supply.
Wire Color Relay Connection
Gray Normally Closed
Blue Common
Green Normally Open
Document # 6050800 Rev 1.1 4 of 12 www.ieib.com