Linear 2010 Quick Start Manual

1-2-5-15 YEAR LIMITED WARRANTY
ChannelPlus/OpenHouse warranty durations are customized by the product type:
1 Year - on cameras, batteries, and power supplies
2 Years - on audio amplifiers and data products
5 Years - on “active” products (amplifiers, modulators, IR receivers)
15 Years on “passive” products (filters, splitters, cables, cabinets)
LIMITED WARRANTY STATEMENT
Linear LLC warrants this product to be free from defects in material and workmanship for 1, 2, 5, or 15 years (see above). The time period will be measured using the date code labeled on the product. Linear LLC is not responsible for damage to the product resulting from the buyer’s improper handling, stocking or warehousing of the product. Any implied warranty arising from the sale of the product including implied warranties of merchantability and fitness for purpose are limited. Linear LLC shall not be responsible for any losses, damages or expenses, whether direct, consequential, or incidental arising from the use or the inability to use the product. Some states and countries do not allow limitations or how long an implied warranty lasts or the exclusion or limitation or incidental or consequential damages, so the above exclusions may not apply. The Linear LLC warranty gives specific legal rights in addition to other rights, which may exist and vary from state to state and country to country.
The warranty is limited to repair or replacement of products returned, freight prepaid, to Linear LLC, there is NO PROVISION FOR LABOR COST OR OTHER REIMBURSEMENTS OF ANY KIND.
1. Failures due to product abuse, such as negligence, improper use, and electrical surge including damage from lightning, water damage or other damage due to natural disasters are not covered by the warranty. The most common form of product abuse is surge damage caused by lightning.
2. The warranty shall also be voided by any tampering with the date code, labels or other markings on the product.
3. Products that are damaged in transit to Linear LLC due to improper packaging or by the carrier (shipping company) will not be covered under the warranty. If the product was damaged or lost by the carrier, it is the sender’s responsibility to create a claim against the carrier.
4. The user is responsible for all labor costs associated with removing, reinstalling and returning the product to Linear LLC.
Linear LLC, at its option, will repair or replace the defective product. Replacements will be made from B-Stock, if an exact replacement is not available, Linear LLC, at its option, will select the nearest equivalent product. The user is responsible for freight charges to Linear LLC. Linear LLC will return warranted repaired or replacements by UPS Ground or an equivalent service. A customer may pay the additional costs for second-day or next-day service.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other impor tant details.
Power Injector
Instruction Manual
Model 2010
Copyright © 2007 Linear LLC 600-084 C
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000
Toll Free FAX (800) 468-1340
www.linearcorp.com
www.channelplus.com
Remote Power Using the model 2010
With remote power, the coax panel can
Power Supply
Power Injector
be placed closest to the output coax lines: in the attic, basement or the garage.
2010
Attention: Incorrect connections can damage the amplifier or 2010.
You may connect a 2100A or a
Correct connections:
model 2100A
IR interface
DC-block directly to an amplifier.
TVs without a 2100A or a splitter without IR must have a DC-block between the it and the amplifier.
CATV or
Ant
modulator
DVD
Note:
The model 2010
must be connected
to the (pwr) port.
Up to 8 TVs
Sending IR Signals on the Coax
If you need to add IR but cannot change to a full coaxial cable panel, use this illustration to build an RF passive IR repeating system. Just add targets and emitters and you’re done.
model 2100A
IR interface
The 2010 has a built-in circuit
Power Supply
model 2512 or
2514 splitter
2010
Power Injector
breaker. If the LEDs on the 2100As are not glowing, unplug the power supply, then plug it back in
Use a DC-Block
when NOT using a
2100A IR interface.
to reset the breaker.
2
Wrong
connections:
DC-blocks
Connecting a splitter or a 75ohm termina­tor DIRECTLY to an amplifier will cause the circuit breaker to trip.
Connect emitters to the 2010 or any 2100A in the system.
Connect targets to any 2100A in the system.
Use IR passing splitters only!
3