Linear 1092-07 User Manual

INSTALLATION INSTRUCTIONS
Power Adaptor Kit
Model 1092-07
The Model 1092 Power Adaptor Kit permits the connection of a three-tab radio control receiver to a garage door operator which does not conform to the three­terminal standard adopted by DORCMA. The operator may have only two terminals or the numbering sequence may be different.
TO CONNECT A THREE-TAB RECEIVER:
receiver terminals.
2. Each terminal is marked on the data label on the back of the receiver.
Connect the wires to the receiver terminals as follows:
a.
Receptacle with two wires (power transformer and push button wire) to terminal mark “1” or “24V”.
b.
Receptacle with second push button wire to terminal marked “2” or “relay”.
c.
Receptacle with remaining transformer wire to
3. Connect the two spade lugs to the wall button terminals on the operator (terminals 1 and 2 on a three terminal operator). Plug the transformer into a 115 VAC outlet.
Copyright © 1999 Linear Corporation 216720 A
terminal marked “3” or “radio power”.
LINEAR CORPORATION 2055 Corte Del Nogal Carlsbad, California 92009
Loading...