Linear 1045 Quick Start Manual

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1045
DESCRIPTION
TELECOM DC/DC CONVERTER
LTC3805
Demonstration circuit 1045 is a Telecom isolated DC/DC converter featuring the LTC3805 constant frequency current mode flyback controller. The DC1045 converts 36V to 72V input voltage to an isolated 3A of output current at 3.3V. The 200kHz constant frequency operation is maintained down to very light load to reduce low frequency noise generated over a wide range of load current. The converter provides high output voltage accuracy (typically ±2%) over wide load range with no minimum load requirement.
The DC1045 also provides non-isolated design by removing opto coupler and LTC4430 circuit. The demonstration circuit can be easily modified to generate different output voltages up to 15V. As
QUICK START PROCEDURE
Demonstration circuit 1045 is easy to set up to evaluate the performance of the LTC3805. For proper measurement equipment setup refer to Figure 1 and follow the procedure below:
When measuring the input or output voltage ripple, care must be taken to minimize the length of the oscilloscope probe ground lead. Measure the input or output voltage ripple by connecting the probe tip directly across the VIN or V see Figure 2.
1.
With power off, connect the input power supply to Vin and PriRTN.
and GND terminals,
OUT
output voltage is increased, the maximum output current must be reduced to limit the output power to no more than 10W. Higher output voltages and currents can achieved by changing the transformer
and output capacitors. Please consult LTC
MOSFET,
factory for details.
The DC1045 has a small circuit footprint. It is a high performance and cost effective solution for Telecom, Automotive and Power-over-Ethernet applications.
Design files for this circuit board are available. Call the LTC factory.
LTC and LT are registered trademarks of Linear Technology Corporation.
power components with higher voltage ratings should be used.
4.
Check for proper output voltage. Vout=3.3V.
If there is no output, temporarily disconnect the load to make sure that the load is not set too high.
5.
To shut the converter down, move the RUN shunt to the OFF position
6.
To synchronize converter to external clock, set jumper JP2 to ‘EXT SYNC’ position, apply signal to FSET pin. See LTC3805 datasheet for sync signal parameters.
2.
Move the RUN shunt to the ON position.
3.
Turn the input power source on and slowly increase the input voltage. Be careful not to exceed 72V. Make sure that the input voltage VIN does not exceed 72V. If higher operating voltage is required,
7.
Once the proper output voltage is established, adjust the load within 3.0A range and observe the output voltage regulation, ripple voltage, efficiency and other parameters.
1
QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1045
TELECOM DC/DC CONVERTER
Figure 1. Proper Measurement Equipment Setup
Figure 2. Measuring Input or Output Ripple
2
Loading...
+ 1 hidden pages