DO NOT operate these pumps with 10” airmotor.
DO NOT exceed the stated maximum working pressure of the airmotor or the
lowest rated component in your system.
DO NOT alter or modify any part of this equipment.
DO NOT operate this equipment with combustible gas.
DO NOT attempt to repair or disassemble the equipment while the system is
pressurized.
TIGHTEN all uid connections securely before using this equipment.
ALWAYS read and follow the uid manufacturer’s recommendations regarding
uid compatibility, and the use of protective clothing and equipment.
CHECK all equipment regularly and repair or replace worn or damaged parts
immediately.
IMPORTANT: Failure to heed these warnings including misuse, over pressurizing, modifying parts, using incompatible chemicals and uids, or using worn or
damaged parts, may result in equipment damage and/or serious personal injury,
re, explosion, or property damage.
MODEL CHART
PUMP PUMPMAXIMUM DELIVERY MAXIMUM AIR DIMENSION "A" DIMENSION "B"
TUBE MODEL AIRMOTOR* RATIOPRESSUREPRESSUREin. (cm.)in. (cm.)
To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com
Form 403663
Section
- A50
Page
- 80A
Models 84981, 84982, 84983, 84984, 84985
POWER-MASTER III DRUM PUMPS
Ball Type Foot Valve
ATTACHING AIRMOTOR TO
PUMPTUBE
1. Tightly attach tie rods to the airmotor
(use short threaded end of the tie rods).
2. Mount airmotor on top of the pump tube
outlet and tightly connect Coupling Nut
(Item 2) to airmotor piston rod.
3. Hand tighten tie rods to the pumptube
with four nuts supplied with airmotor.
4. Slowly cycle the pump several times,
using just enough air pressure to operate
the pump without stalling.
5. Stop the pump on an “up” stroke and
tighten the four nuts to securely fasten
the airmotor to the pumptube.
OPERATING PRECAUTIONS
Use Lincoln replacement parts to assure •
compatible pressure rating
HEED ALL WARNINGS•
Be sure material hoses and other •
components are able to withstand uid
pressures developed by this pump
Do not operate pump continuously at •
speeds in excess of 75 cycles per
minute.
Disconnect air line from pump air motor •
when system sits idle for long periods of
time.
SERVICING Before servicing or •
cleaning pump, or removing uid hose or
gun from a unit that has been used, be
sure to disconnect air lines and carefully
bleed pressure off of the system.
PREVENT STATIC SPARKING. If static
sparking occurs, re or explosion could
result. Pump, dispensing valve, and con-
tainers must be grounded when handling
ammable uids such as petroleum products, paints, lacquers, etc. and wherever
discharge of static electricity is hazard.
Check continuity (a good static wire •
connection) with an ohmmeter Place
one probe on one hose tting and the
other probe on other hose tting, conti-
nuity or proper grounding through hose
is good when a reading is obtained on
the ohmmeter
PREVENT FIRES. When pumping, •
ushing or recirculating volatile solvents, the area must be adequately
ventilated.
Keep solvents away from heat, sparks •
and open ames. Keep containers
closed when not in use.
Page Number - 2
To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com
DO NOT allow pump to operate when
out of material.
PUMP PRIMING
To begin operation, the pump has to
be primed with the pumped material.
The Power-Master III pump is a double
acting (pumps material on ‘up’& “down”
stroke.) positive displacement recipro-
cating pump and as such intakes material only on the “up” stroke.
To prime pump, open output line (material
valve) and slowly open air supply valve
until pump starts. Allow pump to cycle
very slowly until all air is pushed out of
lines and material lls up pump and lines.
Close output line (material shut-off valve)
- pump should stall against pressure
Note: Pumps are factory tested with light
oil and some of it is left in to protect pump
parts during storage and transportation.
To prevent contamination of material to be
pumped, ush pump before using.
84112 Pump Piston Replacement - With Leather V-packings
(standard on Model 84983).
PUMP REPAIR KITS:
86219 - Includes soft parts for Models 84983”, 84984 & 84985
86220 - Includes soft parts for Models 84981 & 84982.
86222 - Piston rebuild kit for Model 84983*.
* Model 84983 requires Kits 86219 & 86222 for rebuild.
Form 403663
To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com
Page Number - 3
Models 84981, 84982, 84983, 84984, 84985
POWER-MASTER III DRUM PUMPS
Ball Type Foot Valve
SPECIFICATIONS
Pump stroke - 6 in (152 mm)
Output per cycle- 11.9 cu m. (195 cc)
Max. recommended speed (continuous) - 75 cycles min
Approx. cycles per gallon (liter) - 20 (5)
Output at 75 cycles/min. - 3.9 gpm (14 6 liter/min.)
ITEMPART NUMBER
NO.DESCRIPTION QTY. Model 84981 Model 84982 Model 84983 Model 84984 Model 84985
To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com
Form 403663
Models 84981, 84982, 84983, 84984, 84985
POWER-MASTER III DRUM PUMPS
Ball Type Foot Valve
Declaration by the manufacturer as dened by Machinery Directive 89/392EEC Annex IIB
Herewith we declare that the supplied model of PowerMaster Pumps 84981, 84982, 84983, 84984 and 84985
Is intended to be incorpoated into machinery covered by this directive and must not be put into service until the machiner into
shich it is to be incorpoated has been declared in conformity with the provisions of the directive 91/386/EEC.
Applied harmonized standards in particular:
EN 292 Safety of machinery - Basic concepts, general principles for design - Part 2: Technical principles and
specications
EN 809 Pumps and pump units for liquids - Common safety requirements
EN 983 Safety of machinery - Safety requirements for uid power systems and their components - Pneumatics
EN 1050 Safety of machinery - Principles for risk assessment
Paul Conley, Cheif Engineer 5/20/07
Americas:
One Lincoln Way
St. Louis, MO 63120-1578
USA
Phone +1.314.679.4200
Fax +1.800.424.5359
Form 403663
To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com