LiftMaster TAC2C User Manual

Installation Guide
IMPORTANT: The TAC2C has a Ringer Equivalence Number (REN) of 5 with or without a TELCO line.

Introduction

DO NOT run data wires and HIGH VOLTAGE wires in the same conduit. The HIGH VOLTAGE wires may interfere with the data wires and cause the unit to malfunction.
To AVOID damaging gas, power or other underground utility lines, contact underground utility locating companies BEFORE digging.
To prevent damage to the unit:
• Use the new 16 Vdc transformer ONLY.
• Use dedicated 110 Vac outlet ONLY.
IMPORTANT NOTE: DO NOT use the existing transformer, the provided transformer MUST be used instead.
Unplug the transformer from the outlet. Disconnect the wires from the existing transformer.

CARTON INVENTORY

Hardware Bag
Complete with: Hex Head Tamper Resistant Screws (4), Hex Tool (1), and Ground Lug (1)
Faceplate with Processor Board (1)
16 Volt DC 2.5 Amp Transformer (UL Listed) (1)
Install and Programming Guide (1)
Labels (9)
Remove the screws from the Crown Jewel faceplate using the provided hex tool.

SPECIFICATIONS

Power Supply: 16 Vdc 2.5 Amp
The 110 Vac outlet must be dedicated to the unit only. This outlet should be wired back to its own 10 Amp minimum circuit breaker. This will prevent two problems:
• Other equipment cannot introduce spikes, noise, surges, or dips into the power circuit.
• The unit’s operation will not be affected if any other equipment develops a short circuit across the power line.
Dimensions: 9.72" x 6.22" (W x H)
Slide the faceplate forward and rotate downward.
Identify the terminal blocks on the Crown Jewel board. Attach the provided labels to the
corresponding wires as shown. Once the wires are labeled, remove them from the board.
When the wires have
been labeled correctly,
remove the terminal
blocks from the board.
The relay wires will need to be
removed and re-wired to the terminal
block on the new board.
RELAY 2, NO
RELAY 2, NC
RELAY 2, COM RELAY 1, NO
RELAY 1, NC
RELAY 1, COM
COLOR LABEL DESCRIPTION
POWER 16 Volt DC power input
AUTOCALL Input for accessory device to trigger home dialing
TAC1 RETROFIT KIT FOR CROWN JEWEL SYSTEMS
Remove the ground wire that runs from the board
to the ground screw in
the existing housing.
POWER
RELAY 2
EXTERNAL KEYPAD (no longer available)
RELAY 1
Exit Terminal Block
(no longer available)
Autocall
Terminal
Block
AUTOCALL
EXIT
(no longer available)
CROWN JEWEL BOARD
Remove the screws (2) securing the faceplate to the
housing.
TAC2C
Separate the Exit terminal block
from the Autocall terminal block by
sliding them apart as shown.
Ground Wire
PHONE/TELCO
6.22"
Speaker
9.72"
1
4
7
*
Keypad
Microphone
2
3
6
5
9
8
0
#
Call Button
PHONE/TELCO Input connection for TELCO
RELAY 2, NO NO input for Relay 2
RELAY 2, NC NC input for Relay 2
RELAY 2, COM COM input for Relay 2
RELAY 1, NO NO input for Relay 1
RELAY 1, NC NC input for Relay 1
RELAY 1, COM COM input for Relay 1
R
E
L
A
Y
1
C
O
M
R
E
L
A
Y
1
N
O
R
E
L
A
Y
1
N
C
R
E
L
A
Y
2
N
C
R
E
L
A
Y
2
N
O
R
E
L
A
Y
2
C
O
M
Attach the labeled wires to the new TAC2C board as shown.
Crimp the ground lug onto the end of the
ground wire on the new board. Attach the
ground lug to the ground screw in the
existing housing.
Rewire the relay 1 and 2 wires
to the relay 1 and 2 terminal
blocks on the new board.

Testing

TEST GATE / DOOR RELAYS
Test Relay 1
Remove the PHONE, POWER, and AUTOCALL
terminal blocks from the new board. Leave the
Relay 1 and 2 terminal blocks.
POWER
PHONE/TELCO
AUTOCALL
Ground Wire
Ground Lug
RELAY 1
Ground Screw
in existing
housing
RELAY 2
PHONE/TELCO
NEW TAC2C BOARD
POWER
AUTOCALL
Enter 4 digit Master Code.
2
R
Y
E
A
1
R
E
Y
L
A
N
C
1
R
E
Y
L
A
N
O
1
R
E
Y
L
A
C
O
M
R
E
L
L
M
O
C
2
R
Y
E
A
L
O
N
2
Y
A
C
N
1
Press 1 to test Relay 1.
2
Test Relay 2
NO
RELAY 1
COM
NC
RELAY 2
NO
COM
Enter 4 digit Master Code.
1
Press 2 to test Relay 2.
2
NC
When wiring is complete, secure the new faceplate to
7 9
the existing housing with the provided screws (4).
Connect the power wires to the new transformer and plug the transformer into a 110 Vac outlet ONLY, any other type of outlet will cause damage to the unit.
indicate that it is powered, and is waiting to be programmed for the unit’s Master Code. The Master Code is used to unlock the programming functions of the unit. The Master Code should not
1
4
7
*
2
3
5
6
8
9
0
#
NEW 16 Vdc Transformer
(provided)
110 Vac Outlet ONLY
IMPORTANT NOTE: DO NOT use the existing transformer, the provided transformer MUST be used instead.
be distributed as a User Code.
1
2
“BEEP” “BEEP”
3
SET THE MASTER CODE
Once power is applied, the unit will begin to “click” to
Enter on the unit’s keypad.
Enter 4-digit Master Code. Example: 1234.
Write down the Master Code and store in a secure location.
TEST THE TELEPHONE CONNECTIONS
Place a telephone call from the resident’s telephone to verify
1
the unit is operating properly, then hang up the phone.
Press the “Call” button on the unit’s keypad. The telephone in
2
the residence should ring.
To test Relay 1 have someone answer the telephone and enter
3
“*9” (Star + 9) to activate Relay 1. The unit will disconnect the call as soon as the relay is activated. To test Relay 2 have someone answer the telephone and enter “*5” (Star + 5). Relay 2 should activate. The unit will disconnect the call as soon as the relay is activated.
For complete programming information refer to the Programming Guide.
© 2011, The Chamberlain Group 01-35895B All Rights Reserved