Lift-Master SOLAR3 User Manual

MODEL SOLAR3
53.78"
29.16"
CORRECT Panel Placement
Installation must be free of obstructions that block sunlight. Install facing SOUTH.
Panel should be tilted between 40° and 45°
MAINTENANCE: Solar modules require little maintenance. It is not uncommon for a remote site to be checked once a year. Under most conditions,
normal rainfall is sufficient to keep the power modules clean. If dirt build-up becomes excessive, clean the solar panel with a soft cloth, mild detergent and water. Modules that are mounted flat (0° tilt angle) should be cleaned more often as they will not "self clean" as effectively as modules mounted at 15° tilt or greater. Once a year, check the general condition of the wiring and connections. Also, check to be sure that mounting hardware is tight. Loose bolts could result in a damaged module or array.
Solar3 thin film, power modules convert sunlight directly into electricity using advanced thin film technology. The Solar3 is durable, shadow-tolerant, and reliable.
WARNING-ELECTRICAL HAZARD This solar electric product
is a LIVE power source in sunlight. OBSERVE CAUTION and read instructions.
Wiring to a Non-Surge Suppressor “Robo”
Use the yellow wires from the J1 plug. (Polarity does not matter). Connect the wires from the solar panel to the yellow wires from the J1 plug on the control board. Sunlight will energize the battery through the solar panel.
Wiring to a Surge Suppressor “Robo”
Connect the two wires from the solar panel to the Power Input connection on the surge suppressor (Polarity does not matter). Sunlight will energize the batteries through the solar panel.
W
N
South
E
SPECIFICATIONS
Electric Ratings at 1000 W/m2, AM1.5, Cell Temp. 25C Max Power: Current Max Power: Voltage Max Power: Short Circuit Current: Open Circuit Voltage:
Model Type: Max System Voltage: Series Fuse: Min. Blocking/Bypass Diode: Field Wiring:
64 W
3.88 A
16.5 V
4.8 A
23.8 V
US-64 600 V
8.0 A
8.0 A Copper only, 18-10 AWG Insulated for 90C Min.
During initial 8-10 weeks of operation, the module has higher electrical output than rated output. The output power may be higher by 15%, the operating voltage may be higher by 11% and operating current may be higher by 4%.
INCORRECT
Panel Placement
DO NOT install solar panel near trees or buildings that will block the sunlight. To do so will lose charging efficiency.
D
A
O
L
R
E
V
O
REW
OP
W
O
L
Y
R
E
T
T
A
B
Y
AL
ER
N
E
PO
Y
AL
E
R
E
SOLC
R
EMI
T
P
U
NO
1 W
F
FO
O
PE
N
T
O RIG
H
T
0
6
0
W
P
LO
R
T
N
OC
L
A
R
T
NE
C
S
Y
S
TE
M
O
N
D
C
O
P
E
R
A T
O
R
v
5M
AS
U N
I
E
D
A
M
A
L A
R
M
SE
N
S O
R
R
EVER
SE
S
E
N SO
R
H
EA
VY
G
A T
E
F
I R
E
DE
P
T
S
T
R
IK
E
O
P
E
N
S
AFE
TY
LO
O
P
E
X
IT
L
O
O
P
RADI
O
RE
C
C
H
A
R
G
I N
G
POWE
R
BO
A
RD
POWER
K
C
E
H
C
E
S
U
F
2
J
KO
EG
RA
H
C
Polarity Does
Not Matter
2
1
3
5
6
8
1
0
7
9
4
Yellow Wires #2, #4
Solar3 “Robo” Installation Non-Breakable Solar Panel
For Technical Support: 1-800-528-2806
© 2005 The Chamberlain Group, Inc.
All Rights Reserved
®
Polarity Does
Not Matter
®
STRIKE OPEN
PUSH BUTTON
STRIKE OPEN
PUSH BUTTON
FIRE DEPT
KEY SWITCH
FIRE DEPT
KEY SWITCH
CLASS 2
SUPPLY
CLASS 2
SUPPLY
SAFETY
LOOP
SAFETY
LOOP
POWER INPUT
18 VAC
POWER INPUT
18 VAC
RADIO
RECEIVER
RADIO
RECEIVER
EXIT
LOOP
EXIT
LOOP
––
++
P/N Q412
PATENT PENDING
P/N Q412
PATENT PENDING
ROBO SURGE SUPPRESSOR
®
ACCESS SYSTEMS INCACCESS SYSTEMS INCACCESS SYS TE MS INC
7 1312111098
1 654
––
AC AC
Do Not use solar panel and plug-in transformer at the same time.
Type 1:
Type 2:
Solar3 “Miracle-One™” Installation Non-Breakable Solar Panel
For Technical Support: 1-800-528-2806
845 Larch Avenue Elmhurst, Illinois 60126
www.chamberlain.com
© 2005 The Chamberlain Group, Inc.
All Rights Reserved
01-50743B
®
Refer to other side for panel: dimensions, specifications, correct placement and maintenance.
Don’t use solar panel
and plug-in transformer at the same time. Please contact technical support for this type of dual power connection. Ref. doc. # 01-51266
Solar3 thin film, power modules convert sunlight directly into electricity using advanced thin film technology. The Solar3 is durable, shadow-tolerant, and reliable.
WARNING-ELECTRICAL HAZARD This solar electric product
is a LIVE power source in sunlight. OBSERVE CAUTION and read instructions.
A plug-in solar power adapter (Sold separately) can be use as a “power option” for the Miracle-One™. Simply plug in the adapter to the existing electronic control box. No other modifications are necessary. The solar panel provides solar power for the Miracle-One™ single and double arm operators.
DC Power Adapter (Purchased separately) needed
for solar panel connection to the Miracle-One™.
DC Power Adapter
Part # ASOLARADP
Connector from Miracle-One™ J1 Plug
Battery Connector from Miracle-One™
Solar Panel Wires
8
BLACK
MOTOR
WHITE
RED
BRAKE
SINGLE OR MASTER ONLY SECOND ONLY
BROWN
BLUE
LIMITS
GREEN
BLACK
MOTOR
WHITE
RED
BRAKE
BROWN
BLUE
LIMITS
GREEN
CENTER
LOOP
+24 VAC
INPUT
SAFETY
LOOP
STRIKE
INPUT
BURGLAR
ALARM
INPUT
GROUND
RADIO
+24 VOLT
UL SENSOR
LAKE FOREST, CALIFORNIA
www.eliteaccess.com
REV A
MIRACLE SURGE PROTECTION
1 2 3 45 6 7 8 9101112 13141516 1718192021222324252627
®
DC Power Adapter fits inside the Miracle-One™ electronic box
Loading...