2) Never let children operate or play with gate controls. Keep the remote control away from children.
3) Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
4) Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors.
After adjusting the force or the limit of travel, re-test the gate operator. Failure to adjust and re-test the gate operator properly can increase the risk of
injury or death.
5) Use the emergency release only when the gate is not moving.
6) KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a qualified service person make repairs to gate hardware.
7) The entrance is for vehicles only. Pedestrians must use separate entrance.
8) SAVE THESE INSTRUCTIONS.
pg 2
The following models are not currently ETL approved: SL930-DC-BB
POWER REQUIREMENT: Dedicated 115 Volt AC (+/- 10V), 5 AMP Power Circuit
APPLICATIONS:
z Maximum Gate Weight: 1,500 pounds
z Maximum Gate Length: 40 feet
z Maximum Track Grade: 5% (1ft rise over 20ft run)
z Maximum Gate Speed: 10in/sec
BASE PLATE HOLE PATTERN
INCLUDED WITH OPERATOR:
z 40-Feet of # 40 Roller Chain
z 2-Master Links # 40
z 2-Zinc Plated Chain Bolts
z 2-Chain Brackets, Right and Left
z 2-U-Bolts, Round (for chain brackets)
z 2-U-Bolts, Square (for chain brackets)
z 2-Safety Safety Warning Placards
z 1-Hex Wrench 5/16"
z 1-Instruction Manual
z 1-Flexible Conduit End Fitting 1/2"
z 4-Sleeve Anchor Bolts (red heads) 3/8" X 3"
z 1-Hex Bolt with Nut, 1/4"-20
z 1-Self Tapping Screw, 1/4"-20
pg 3
General Information continued...
CIRCUIT BOARD:
The SL930 uses the Full Systems Capability circuit board, a powerful control
system. This circuit board operates on 12 ~ 18 Volts and can deliver power to the motor through high
power external switching. The limit switch input terminals require the use of normally open type limit
switches. These switches are used to accurately stop the gate operator in the open and closed positions.
To safeguard the operator from damage that could result from limit switch or gate sensitivity failure, the
Full Systems Capability circuit board has a built-in maximum run timer which will allow the operator to run
for approximately 300 seconds and then shut off automatically. The Full Systems Capability circuit board
has an adjustable gate sensitivity feature which will stop or reverse the gate if the gate is pushing harder
than normal because of an obstruction.
GATE SENSITIVITY: The SL930 Full Systems Capability circuit board has a built-in safety
feature which when adjusted properly will deliver only enough power to the motor to overcome the
resistance of the gate. The amount of power that the circuit board will deliver can be adjusted for both
directions of travel to accommodate the various gate weights that the SL930 operator is recommended
for. (See Applications Pg. 3)
Vehicular Gate Operator Classes:
Class I - Residential Vehicular Gate Operator: A vehicular gate operator (or system) intended for use in a home
of one-to four single family dwelling, or a garage or parking area associated therewith.
Class II - Commercial/General Access Vehicular Gate Operator: A vehicular gate operator (or system) intended for
use in a commercial location or building such as a multi-family housing unit (five or more single family units),
hotel, garage, retail store, or other building servicing the general public.
Class III - Industrial/Limited Access Vehicular Gate Operator: A vehicular gate operator (or system) intended for
use in an industrial location or building such as a factory or loading dock area or other locations not intended
to service the general public.
Class IV - Restricted Access Vehicular Gate Operator: A vehicular gate operator (or system) intended for use in a
guarded industrial location or building such as an airport security area or other restricted access location not
servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
Gate Operator model SL930 is intended for Vehicular Gate Operator Classes I, II, III, and IV.
Gate Inspection:
a) Install the gate operator only when:
1) The operator is appropriate for the construction of the gate and the usage Class of the gate,
2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum
of 4' above the ground to prevent a 2-1/4" diameter sphere from passing through the openings anywhere in
the gate, and in that portion of the adjacent fence that the gate covers in the open position.
3) All exposed pinch points are eliminated or guarded, and
4) Guarding is supplied for exposed rollers.
b) The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a
separate access opening.
c) The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent
structures then opening and closing to reduce the risk of entrapment.
d) The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
Do not over-adjust the gate sensitivity to compensate for a damaged gate.
pg 4
Features
OPERATION
The SL930 Full Systems Capability can operate in a AUTO CLOSE TIMER (TIMER ON) or a
PUSH-TO-OPEN/PUSH-TO-CLOSE (TIMER OFF) mode of operation. In the AUTO CLOSE TIMER
mode of operation the operator is given a command to open the gate and hold it open until the input is
released and until the auto close timer has elapsed at which point the operator will close the gate
automatically. In the PUSH-TO-OPEN/PUSH-TO-CLOSE mode of operation each time a signal is sent to
the operator, it will cause it to do the opposite of what it did before. (i.e., If the gate is closed, it will start
opening, if it is open, it will start closing: If it is closing, it will REVERSE TO OPEN, if it is opening, it will
REVERSE TO CLOSE.)
CONTROLS
The SL930 Full Systems Capability works with the following control devices: Key switches, Push
buttons (separate or intercom), numerical key pads and any peripheral equipment which can supply
normally open or normally closed contacts as well as optional radio transmitters and receiver (specified
by and available from the manufacturer). These contacts can be connected to the operator input terminals
to perform the opening, close, safety, or the stop functions.
AUTO CLOSE TIMER
The operator comes factory preset with the auto close timer turned OFF. The auto close timer will
close the gate automatically after a specific amount of time has elapsed. The amount of time can be
easily adjusted between 0 and 45 seconds by turning a small "pot" located on the right edge of the circuit
board (See page 17). The timer can be disabled or activated by flipping a single switch located on the
top right edge of the circuit board. If the timer will be used it is recommended that some type of
supplementary safety device be installed. If more time is required, there is an extended timer available
from the manufacturer allowing up to 100 additional seconds.
MANUAL RELEASE SWITCH
This simple on-off switch is built into the operator. In an emergency, EVEN WITH THE POWER
OFF, the gate can be pushed open manually after flipping the switch from Operate to Release.
GATE SENSITIVITY ADJUSTMENT
The amount of force necessary to stop the gate can be adjusted to conform to the various sizes
and weights of any particular gate. When adjusting the sensitivity, the operator can be given only as much
energy as is necessary to overcome the resistance of the gate. If the gate should strike an obstruction in
either direction, the gate will reverse. If the gate should again strike an obstruction before reaching a limit,
the gate will stop, remain stopped, and will sound an alarm. (See page 17)
MASTER AND SECOND
Some very large entrances may require the use of two gates. If this is the case, the two gates can
be easily automated using the "master and second" configuration. This configuration uses two gates and
two operators in ONE driveway. [ The operators used are two regular SL930 Full Systems Capability
operators. One of which is of standard "right hand operation" and the other which is easily converted to
"left hand operation" by flipping a single switch located at the top of the circuit board. (See page 17)]
pg 5
Parts Identification
pg 6
Parts Identification continued...
X
C
K72-40359 SERVICE KIT LIMIT/DRIVE SHAFT ASSEMBLY
LIMIT/DRIVE SHAFT
BEARING
LIMIT NUT
SPROCKET, 41B20, 1/4" KW, (2) 1/4" SS
KEY, WOODRUFF, 1/4" X 7/8"
Steel shim washer, 1" x 1.5" x 0.010"
Steel shim washer, 1" x 1.5" x 0.031"
HEX BOLT, 3/8-16 X 1"
FLANGE NUT, 3/8-16
E-RING, 1"
K74-40084 BRIDGE RECTIFIER ASSEMBLY
CAPACITOR, RECTIFIER
BRIDGE RECTIFIER 1
SCREW, PH PHILLIPS, #6-32 X 1"1
FLANGE NUT, 6-321
K75-40349 SERVICE KIT GEAR BOX, W/ SPROCKET
GEAR BO
HEX BOLT, 1/4-20 X 3/4"
LOCKWASHER, 1/4"
KEY, 1/8" X 1-1/8
SPROCKET, 41B14 X 7/8" BORE
K74-40347 SERVICE KIT LIMIT SWITCH
LIMIT SWITCH PLATE1
FLANGE NUT, #8-322
LIMIT SWITCH2
LIMIT SWITCH ACTUATOR PLATE1
LOCKNUT, #8-322
RUBBER GROMMET, 7/16" DIA.x 1/16"
SCREW, PH PHILLIPS, #4-40 X 5/8"4
SCREW, PH PHILLIPS, #8-32 X 1"2
SCREW, PH PHILLIPS, #8-32 X 5/8"2
SPRING, LIMIT PLATE2
K74-40045 SERVICE KIT - PCB GUARD AND STANDOFF
GUARD, PCB1
JUMPER, PCB3
HEX STANDOFF, 6-32 x 1", M/F
HEX STANDOFF, 6-32 x 1/2", F/F
SCREW, PH PHILLIPS, #6-32 X 1/4"4
SCREW, PH PHILLIPS, #6-32 X 3/8"4
DESCRIPTION
DESCRIPTIONQTY
DESCRIPTIONQTY
DESCRIPTIONQTY
DESCRIPTION
QTY
QTY
A
1
2
2
1
1
1
2
4
4
1
B
1
C
1
4
4
1
1
D
1
E
4
4
K74-40065 SERVICE KIT EXTERNAL RESISTOR
EXTERNAL CURRENT RESISTOR
SHRINK WRAP, 1" 2
SCREW, PH PHILLIPS, #2-56 X 1/2" 2
LOCKNUT, #2-562
WIRE, GREEN, 8", STIP X FORK1
WIRE, YELLOW, 8", STIP X FORK1
K75-40346 SERVICE KIT IDLER SPROCKET
SPROCKET, 41B24, 3/16" KW, (2) 1/4" SS
BEARING, 1/2" ID x 3/4" OD x 1/2"
HEX BOLT, 5/8-11 X 2-3/4", GRADE 5
HEX JAM NUT, 5/8-11
LOCKWASHER, 5/8
K75-40401 SERVICE KIT DRIVE SPROCKET
KEY, WOODRUFF, 1/4" X 7/8"1
DESCRIPTION QTY
DESCRIPTION
DESCRIPTION
SPROCKET, 41B20, 1/4" KW, (2) 1/4" SS1
K75-40403 SVC. KIT, REDUCTION SPROCKETJ
DESCRIPTIONQTY
SPROCKET, 35B54, 1" Bore
KEY, WOODRUFF, 1/4" X 7/8"1
K74-40378 SERVICE KIT OPERATOR COVER
COVER, SL920 & 9301
LABEL, LIFTMASTER BUBBLE1
SCREW, SOCKET, 3/8-16 X 1" 4
WASHER, 5/16, INTERNAL GRIP, PLASTIC
412HM RADIO1
CABLE EXTENSION KIT
STICK-ON CABLE FASTENER2
6-32 x
½
6-32 x 1 HEX MALE/FEMALE STANDOFF2
#6 FLAT WASHER2
#6 LOCK WASHER2
#6 NUT2
3" STRIP OF FLEX-GROMET 1
DESCRIPTION
50-19914 RADIO KIT (OPTIONAL)
DESCRIPTIONQTY
PAN HEAD SCREWS
F
1
G
QTY
1
1
1
2
1
H
QTY
1
K
QTY
4
1
2
INDIVIDUAL PARTS
ITEM
1
2
3
4
5
6
7
8
9
10
11 29-NP712 BATTERY, 12V 7AH 1
12
13
25-2008 CIRCUIT BREAKER
14
PART #
13-40362
20-40351
21-40074
21-40359
23-40050
23-40357
25-40356
29-40089
29-40355
29-40376
K79-40056
K79-40370
DESCRIPTION
LIMIT NUT 2
MOTOR, 1/2 HP 90 VDC
XFMR, 120V, 60HV1
TRANSFORMER, 120V, 50/60H
LIMIT SWITCH2
SWITCH SPST, TOGGLE
CIRCUIT BREAKER, 5 AMP
SONALERT PIEZO ALARM
RESISTOR 10 OHM
RELAY 900D SPDT, 12 Volt DC2
PCB, COMPLETE, FULL SYSTEM
PCB, FINGER, BATTERY 1
QTY
1
1
1
1
1
1
1
1
pg 7
Installation
TEST OPERATOR
1
SET TRANSMITTER SWITCHES
2
Remove the gate operator from it's
package and make sure that all parts are
included. Refer to General Information and
Parts Identification. If any parts appear to be
missing, contact dealer.
Temporarily plug the operator into
115 Volt outlet or extension cord.
Before beginning installation, test the
gate operator by running the operator back
and fourth 2 or 3 times. If the gate operator
appears to have any shipping damage,
contact a dealer.
The operator may be run back and
fourth by momentarily touching the open input
terminals together. The terminals can be
touched together with a short length of wire,
paper clip or needle nose pliers. With the full
systems capability circuit board, the open
input terminals are 5 and 6.
Disconnect Power when finished!
pg 8
GATE PREPERATION
3
Installation continued...
Disconnect Power from the gate
operator!
The tail end of the gate should
extend approximately 24" beyond the edge of
the driveway. If this is not the case, an
extension tail will need to be added to the
gate. This will give room for the gate operator.
Make the extension tail 24" X 24" as shown.
If the gate has not yet been fabricated, add
24" to the length of the gate.
CEMENT PAD LOCATION
4
OPTIONAL MOUNTING STAND
5
If no concrete surface exists to
attach the gate operator to, make a cement
pad 16" X 24" X 10". The cement pad should
be at least 6" in depth and extend below frost
line. If it is desirable to elevate the gate
operator it may protrude 4" or more above
ground as shown. Place the shortest pad
edge even with the driveway edge. Place the
longer edge of the pad 1" away from the gate.
If the steel mounting stand will be
used, place the shortest edge of the stand 4"
from the driveway edge and place the longest
edge of the stand 4-1/2" away from the gate.
The top of the steel stand may sit on the
ground or the stand may be elevated to keep
the operator above snow, flooding etc. Make
a post hole and cement the stand in place,
making sure the stand is level and square to
the gate.
pg 9
Installation Continued...
POSITION GATE OPERATOR
6
ANCHOR THE OPERATOR
7
If the steel mounting stand was used,
simply bolt the gate operator to the stand. If
the operator will be mounted to a concrete
surface or pad, place the shortest edge of the
operator 4" away from the edge of the
driveway. Place the longer edge of the gate
operator 2-1/2" away from the gate.
When the gate operator is correctly
positioned on the concrete surface or pad,
mark the base hole locations onto the
cement with a felt tip marker or equivalent.
Once marked, move the operator to the side
and drill the 4 holes using a 3/8" masonry bit.
Place the operator back into position. Insert
the four sleeve anchors into the holes and
firmly tighten.
THREADING THE CHAIN
8
Now that the operator is firmly
attached, the chain may now be connected to
the gate and operator. Begin by threading the
chain through the sprockets. The sprockets
come arranged as shown so that the chain
may be threaded under the idler sprockets
and over the drive sprocket. Alternately, the
chain may be threaded over the idler sprockets and under the drive sprocket by moving
the idler sprockets to the alternate positions
above. Note: the cover will need to be modified for the alternate arrangement.