Lift-master OQCCOMNI User Manual

Part # OQCCOMNI
QCC
Quick Close Curcuit for Slide Gate Operators Only
Requirements
A) Vehicular Slide Gate Operator with OmniControl board B) Optional Omni board C) QCC access ID D) Safety Loop
Installation
1. Turn the gate operator electrical power off
2. Turn the timer on at the Omni control board
3. Insert the optional Omni board into the OmniControl board at J2
4. Insert the QCC access ID into the QCC socket
5. Select the desired function of the QCC operation.
6. Turn the gate operator electrical power on
QCC Access ID (Top Positive)
+
CENTER SAFETY EXIT
Optional Omni Board
QCC
W4
A B
G B
A
MS LINK
OPEN STOP CLOSE MAGLOCK ALAR
CENTER SAFETY EXIT
QCC Access Socket
+
OPEN
M
M/S LIN
ARMED
OmniControl Board
QCC
A
CLOS E
STOP
ALARMSENSOR
DC-BACKUP
SYSTEM ON
K
SENSORS
1 3
ALARM
SENSOR
MAGLOCK
COMMAND
PROCESSED
TIMER
OFF
1 3
SENSOR
REVERSE
OPEN LEFT
FIRE
STRIKE
RADIO
DEPT.
OPEN
RECEIVER
EXIT
SAFETY
CENTER
LOOP
LOOP
LOOP
M
ALAR
60
ON
OPEN RIGHT
LOCKED
MOTOR
POWER
3
OVERLOAD
1 3
GATE
RESET
OPEN
STOPCLOSE
MADE IN USA
Optional Omni Board
Mode of Operations
Mode of Operation Switch
The QCC can operate in two different modes. The mode of operation will depend on the switch setting on the optional Omni board.
OPEN
QCC
STOP
A
CLOS E
B
MAGLOCK
Mode A (switch to left) If the gate is closing while a car is driving over the safety loop detector, the QCC will stop the gate for a second then open the gate while the car is over the safety loop detector. As soon as the car leaves the safety loop, the QCC will resume closing the gate.
Mode B (switch to right) If the gate is closing, and a vehicle drives over the safety loop, the QCC will stop the gate. It will not open the gate. After the vehicle leaves the safety loop, the QCC will close the gate.
01-50571
For Technical Support: 1-800-528-2806
© 2005 The Chamberlain Group, Inc.
All Rights Reserved
845 Larch Avenue Elmhurst, Illinois 60126
www.chamberlain.com
®
Loading...