LiftMaster MGJ User Manual

MH 5011E
MHS 5011E
MEDIUM DUTY LOGIC

USER’S GUIDE

MT 5011E BMT 5011E
MGJ 5011E
Contact Information
Installation Date
www.liftmaster.com
Radio Receiver Built on Board
315MHz
WARNING
CAUTIONCAUTION
WARNING
WARNING

INTRODUCTION

Congratulations on purchasing a quality, LiftMaster Medium Duty Commercial Door Operator. Your new operator is capable of operating up to 12 cycles per hour or 50 cycles per day. It is
existing 315 MHz product line as well as a Timer To Close (TTC) feature that can be enabled when LiftMaster Commercial Protector
®
System
is installed and aligned properly.
equipped with a built in radio receiver that is compatible with our

BASIC PROGRAMMING

DETERMINE THE WIRING TYPE

The functionality of this operator is based on the wiring type. The operator is shipped from the factory in standard C2 wiring type (factory default). Some wiring types will require an optional safety device. Refer to the following descriptions of wiring types, requirements and programming.
NOTE: 1. The LED on the logic board will blink once when in C2
and twice when in B2.
2. The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. If the Monitored Safety Device is removed, the operator will go into a Restricted Close mode**. Turn power OFF and ON to reset wiring type.
** Restricted close mode requires a constant pressure close
command. The operator will begin closing after a 5 second delay and will continue to close to the close limit switch. The operator will stop if the pressure to close is released before reaching the close limit.

C2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE

A
(Factory Default)
• Momentary contact to open and stop with constant pressure to close.
• Open override that reverses when closing by any opening device.
• Wiring for safety device to reverse. NOTE: The operator
will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices)
• Timer to Close (TTC) feature not available.
NON-MONITORED SAFETY DEVICE MONITORED SAFETY DEVICE
To prevent possible SEVERE INJURY or DEATH, install reversing sensors when:
• The radio is used.
• The 3-button control station is out of sight of the door.
• Or ANY other control (automatic or manual) is used. Reversing devices are recommended for ALL installations.

C2 WIRING TYPE WITH MONITORED SAFETY DEVICE

B
• Momentary contact to open and stop with constant pressure to close.
• Open override that reverses when closing by any opening device.
• Wiring for safety device to reverse. NOTE: The operator
will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices)
• Timer to Close (TTC) feature not available.
Sensing Edge
RESET TO C2 WIRING TYPE (Factory Default) TO PROGRAM
Remove any monitored safety devices. Disconnect then reconnect power to the operator.
Press and hold the LEARN and CLOSE buttons until the LED goes out (approximately 3 seconds).
Press and hold the LEARN and STOP buttons until the LED goes out (approximately 3 seconds).
Electrical Box
TP1
C9
L5
^^^^
AUX ANT
AUXANT
C18
R27
J2
TTC
LED
1234567
LMEP1 LMEP2
D9
Logic Board
LEARN
D14
D7
D5
U4
D6
D4
J4
014A1030
C32
C20
R25
U1
C21
C31
D14
K2 LT
LEARN
STOPCLOSE OPEN
C29 R24 P1
STOP CLOSE OPEN
INTRLKCOM
LED
1 23 4567
STOP CLOSE OPEN
Electrical Box
C20
TP1
C9
C21
L5
^^^^
AUX ANT
AUXANT
C18
R27
J2
D14
LEARN
STOPCLOSE OPEN
TTC
LED
1234567
LMEP1 LMEP2
STOP CLOSE OPEN
INTRLKCOM
D9
2
014A1030
Logic Board
J4
C32
R25
U1
C31
K2 LT
C29 R24 P1
Photo Eye
LEARN
D14
D7
D5
U4
D6
D4
LED
STOP CLOSE OPEN
1 23 4567
BASIC PROGRAMMING

B2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE

C
Requires a non-monitored safety device.
• Momentary contact to open, close and stop.
• Open override that reverses when closing by any opening device.
• Wiring for safety device to reverse. NOTE: The operator
will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices)
• Timer to Close (TTC) feature not available.

B2 WIRING TYPE WITH MONITORED SAFETY DEVICE

D
• Momentary contact to open, close and stop.
• Open override that reverses when closing by any opening device.
• Wiring for safety device to reverse. NOTE: The operator
will automatically convert to B2 wiring when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices)
Timer to Close (TTC) feature available.
NON-MONITORED SAFETY DEVICE MONITORED SAFETY DEVICE
Sensing Edge
Photo Eye
TO PROGRAM
Start with operator in factory default C2 mode. Press and hold the LEARN and CLOSE buttons until the LED goes
out (approximately 3 seconds).
Logic BoardElectrical Box
D7
D5
U4
D6
D4
J4
014A1030
C32
C20
TP1
L5
^^^^
R27
TTC
LED
1234567
LMEP1 LMEP2
R25
U1
C21
C31
C18
D14
K2 LT
LEARN
STOPCLOSE OPEN
C29 R24 P1
STOP CLOSE OPEN
INTRLKCOM
LED
D14
LEARN
STOP CLOSE OPEN
1 23 4567
C9
AUX ANT
AUXANT
J2
D9
NO PROGRAMMING REQUIRED
3
L
O
OPEN
BASIC PROGRAMMING

REMOTE CONTROLS

SINGLE BUTTON REMOTE CONTROL
Built in 315 MHz radio receiver permits as many as 20 Security remote controls or dip switch remote controls in any combination.
TO PROGRAM
1. Press and release the LEARN button (LED will light).
2. Press and hold the button on the remote control until the LED flashes rapidly, then release to complete programming (LED will go out).
3. Repeat steps 1 and 2 for additional remote controls.
Electrical Box
014A1030
C20
TP1
C9
C21
L5
^^^^
AUX ANT
AUXANT
C18
R27
J2
D14
LEARN
STOPCLOSE OPEN
TTC
LED
1234567
LMEP1 LMEP2
STOP CLOSE OPEN
INTRLKCOM
D9
3-BUTTON REMOTE CONTROL TO OPERATE AS A WIRELESS 3-BUTTON CONTROL STATION
NOTE: The feature will use 3 of the 20 memory channels in the operator.
TO PROGRAM
1. Press and hold the LEARN button (LED will light).
2. Press the desired button on the logic board (OPEN, CLOSE or STOP). Release both buttons.
3. Press and hold the desired button of the remote control until LED flashes rapidly, then release.
4. Repeat steps 1 through 3 to program additional buttons.
TO ERASE ALL REMOTE CONTROLS
Press and hold the LEARN button (over 5 seconds) until the LED goes out. All programmed remote controls will be erased.
Electrical Box
C20
TP1
C9
L5
^^^^
AUX ANT
AUXANT
C18
R27
J2
D14
LEARN
STOPCLOSE OPEN
TTC
LED
1234567
LMEP1 LMEP2
INTRLKCOM
D9
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Logic Board
STOP CLOSE OPEN
LEARN
D14
D7
D5
U4
D6
D4
J4
C32
R25
U1
C31
K2 LT
C29 R24 P1
LED
23 4567
1
EP1 LMEP2
COM INTRLK STOP
OPENCLOSE
Stop
Close
Open
Logic Board
STOP CLOSE OPEN
LEARN
D14
D7
D5
U4
D6
D4
J4
014A1030
C32
R25
U1
C21
C31
K2 LT
C29 R24 P1
STOP CLOSE OPEN
LED
23 4567
1
EP1 LMEP2
COM INTRLK STOP
OPENCLOSE

TIMER TO CLOSE (TTC)

Timer to Close feature enables the operator to close from the open limit after a preset time, adjustable from 5 to 60 seconds.
®
Requires LiftMaster monitored safety device.
TO PROGRAM
1. Begin with door in fully closed position.
2. Press and release the LEARN button (LED will light).
3. Press and release the TTC button.
4. Every press and release of the STOP button will add 5 seconds to the Timer to Close. Example: 30 second TTC = 6 presses of the STOP button.
5. Press and release the TTC button to exit programming mode.
6. The LED will flash once per 5 seconds of timer setting.
The TTC will become active after completion of the next open cycle.
NOTE: The LED does not indicate that timer is running.
TO VERIFY TIMER TO CLOSE (TTC) SETTING
1. Press and release the LEARN button.
2. Press and release the TTC button.
3. Press and release the TTC button a second time.
4. The LED will flash once per 5 seconds of timer setting.
Timer To Close Button
TTC
1
LMEP1 LMEP2
LEARN
STOP CL
LED
D14
2345
COM INTRLK STOP
J4
C32
R25
U1
C31
K2 LT
C29 R24 P1
Logic Board
D7
D5
U4
D6
D4
Electrical Box
C9
L5
^^^^
AUX ANT
AUXANT
R27
J2
TTC
1234567
LMEP1 LMEP2
D9
014A1030
C20
TP1
C21
C18
D14
LEARN
STOPCLOSE OPEN
LED
STOP CLOSE OPEN
INTRLKCOM
CLEAR THE TIMER TO CLOSE (TTC)
1. Press and release the LEARN button (LED will light.)
2. Press and hold the TTC button for 6 seconds.
3. Release the TTC button (LED will go out). The TTC will no longer be active.
TIMER DEFEAT
The TTC can be temporarily disabled by pressing a STOP button. TTC will become enabled after the next open command.
RADIO OPERATION
MODE OPEN CLOSE STOP REVERSE WHILE TTC
CLOSING RESET
B2 X X X X B2 X with X (3 button X X X WHEN TTC remote) OPEN C2 X X X
C
4
NO ECIT
WARNING
CAUTIONCAUTION
WARNING
WARNING
MANUAL DISCONNECT (MODELS MT/BMT & MH)
The operators have provisions for manually operating the door in case of emergency or power failure. Refer to the appropriate instructions for your model operator.

MODEL MT/BMT

Emergency Disconnect
To prevent possible SERIOUS INJURY or DEATH from a falling door or arm:
• DO NOT stand under the door arm when pulling the emergency release.
• If possible, use emergency release handle to disengage trolley ONLY when door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/ or unexpectedly.
• NEVER use emergency release handle unless doorway is clear of persons and obstructions.
TO DISCONNECT DOOR FROM OPENER
Emergency Disconnect
Door Arm
Emergency
Door
Release Handle

MODEL MH

These operators are equipped with a manual hoist. An electrical interlock will disable the electrical controls when the hoist is used. To operate the hoist:
1. Pull the disconnect chain (sash chain) to engage the hoist mechanism. The disconnect chain may be locked in position by slipping the end through the keyhole of the chain retaining bracket mounted on the wall.
Pull emergency release handle straight down. Emergency disconnect will open.
TO RECONNECT DOOR ARM TO TROLLEY
Lift free end of door
Emergency Disconnect
Door Arm
Chain Retaining Bracket (with pad locking provisions)
arm to trolley. Pull emergency handle to allow arm to engage roll pin. Release handle. Emergency disconnect will close.
2. Operate the door in the desired direction by pulling on one side or the other of the continuous loop hoist chain.
3. The disconnect chain must be released from the chain retaining bracket before the door will operate again electrically.
Electrical Interlock with Hoist for Model MH
5
WARNING
CAUTIONCAUTION
WARNING
WARNING
MANUAL DISCONNECT (MODELS MJ/MGJ & MHS)

MODEL MJ/MGJ

This operator has a floor level disconnect chain to disconnect the door from the door operator.
1. To disengage, pull the chain and secure in the disengaged position by slipping the end through the keyhole bracket mounted on the wall. Or if emergency egress device is used, pull handle to disengage operator from door.
2. The door may now be pushed up or pulled down manually.
3. Release the disconnect chain or reset the emergency egress device to operate the door again electrically.
Keyhole Bracket
To prevent possible SERIOUS INJURY from a moving chain, DISCONNECT electric power to the operator BEFORE manually operating your door.

MODEL MHS

This operator includes two methods of manual operation:
1. A disconnect sash chain for push-up/pull-down operation. This chain can be found on the hoist side of the operator. See Manual Disconnect - Model MJ/MGJ for instructions.
2. A hoist engagement sash chain for manual hoist operation. This chain can be found on the clutch side of the operator. See Manual Disconnect - Model MH for instructions.
When operator is disconnected by the manual operation chain, hoist and electrical operation will not function.
Chain Retaining Bracket (with pad locking provisions)
Hoist Chain
Manual Disconnect for Models MJ and MGJ
Electrical Interlock with Hoist Chain (when present) for Model MHS
6
WARNING
WARNINGWARNING

TESTING

Turn on power, LED will flash 7 times on power up. Test all controls and safety devices to make sure they are working properly. If the operator does not function properly, contact your installing dealer.
IMPORTANT NOTES:
• Do not leave power to the operator on unless all safety and entrapment protection devices have been tested and are working properly.
• Be sure you have read and understand all safety instructions included in this manual.
• Be sure the owner or person(s) responsible for operation of the door have read and understand the safety instructions, know how to electrically operate the door in a safe manner and how to manually disconnect the door from the operator.
TEST 3-BUTTON CONTROL STATION
1. Press OPEN button. (The door should move in the open
direction.)
2. Press STOP button. (The door should stop.)
3. Press CLOSE button. (The door should move in the close
direction.)
4. Release CLOSE button. Door should stop if in C2 mode. (The
door should continue closing if in B2 mode.)
5. Press STOP button. (The door should stop.)
TEST LIMIT ADJUSTMENT
1. Press OPEN button. (The door should open.)
2. Allow the door to fully open.
3. Press CLOSE button. (The door should close.)
4. Allow the door to fully close.
5. If the limits are not set properly, contact your installing dealer.
To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric power BEFORE performing ANY maintenance.
TEST THE SAFETY DEVICES (IF INSTALLED)
1. Open the door.
2. Place an obstruction in the path of the photo eyes or sensing edge.
3. Press the CLOSE button.
The door should not close if photo eyes are installed. The door
should close to obstruction and reverse if sensing edge is installed.
4. Remove the obstruction.
5. Press CLOSE button. Door should close.
If door did not reverse from obstruction, check safety devices.
TEST REMOTE CONTROL
* Requires B2 wiring type and compatible LiftMaster remote
control. In C2 wiring the remote control will open the door only.
1. Press remote control button.
2. Door should open. Allow the door to fully open.
3. Press remote control button.
4. Door should close. Allow door to fully close.
7

TROUBLESHOOTING

WARNINGWARNING
WARNING
To locate a dealer in your area visit us online at www.liftmaster.com
CONDITION POSSIBLE CAUSE FIX
OPERATOR WILL NOT RESPOND TO ANY COMMANDS
OPERATOR MAKES NOISE BUT DOOR DOES NOT MOVE
DOOR DRIFTS AFTER OPERATOR STOPS
DOOR OPENS/CLOSES TOO FAR
DOOR REVERSES UNEXPECTEDLY
RADIO FUNCTIONALITY
NO RESPONSE
REMOTE CANNOT BE PROGRAMMED
POOR RANGE
No power
Accessory failure
Possible component failure
Operator requires adjustment
Operator or door requires adjustment
Operator requires adjustment
Safety device activated
Remote control is not programmed
Low battery
Low battery
Low battery
Possible radio interference
Check circuit breaker.
Verify photo eyes are aligned.
Contact your installing dealer.
Contact your installing dealer.
Contact your installing dealer.
Contact your installing dealer.
Verify photo eyes are aligned. If photo eyes are aligned and operator still does
not operate properly, contact your installing dealer.
See PROGRAMMING REMOTE CONTROLS section.
Replace battery.
Replace battery.
Replace battery.
Contact your installing dealer.
MAINTENANCE SCHEDULE
Every 3 months or 5,000 cycles repeat all tests in the Testing section.
Call qualified service contractor for maintenance. To locate a dealer in your area visit us online at www.liftmaster.com.
The operator should be serviced at the following intervals:
• Every 3 months or 5,000 cycles
• Every 6 months or 10,000 cycles
• Every 12 months or 20,000 cycles
To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric power BEFORE performing ANY maintenance.
8
OPERATOR NOTES
9
OPERATOR NOTES
10
OPERATOR NOTES
11
OPEN
CLOSE
OPEN
CLOSE
OPENOPEN
CLOSECLOSE

ACCESSORIES

OPEN
OPEN
1
2
4
5
7
8
*
0
3
6
9
#
OPEN
OPEN
CLOSE
TO
PRESS
RING
OPEN
CLOSE
OPEN
OPEN
TO
PRESS
RING
OPEN
CLOSE
TO
PRESS
RING
OPEN
CLOSE
OPEN
OPEN
CLOSE
OP
E
N
TO
PRESS
RING
OP
E
N
CLOSE
REMOTE CONTROLS 315MHz
371LM
373LM
333LM
WPB1LM
WPB3LM
WKP5LM
1-Button SECURITY® Remote Control:
Includes visor clip.
3-Button SECURITY® Remote Control:
Includes visor clip.
3-Button Tri-Colored Dip Switch Remote Control:
Includes visor clip.
Wireless Single Push Button Control SECURITY®:
Rugged composite housing. (Wireless controls can not be used in place of hardwired controls.)
Wireless 3 Button Control Station SECURITY®:
Rugged composite housing. (Wireless controls can not be used in place of hardwired controls.)
Wireless Access Control Keypad SECURITY®:
Rugged composite housing. (Wireless controls can not be used in place of hardwired controls.)
ENTRAPMENT PROTECTION DEVICES
Monitored
CPS-LN4
Commercial Protector System®:
Provides protection on doors up to 45' wide. NEMA-4 rated.
CPS-L
Commercial Protector System®:
Provides protection on doors up to 30' wide.
Non-Monitored
65-8202
Vehicle Detection System
Pneumatic Sensing Edge Kit
ANTENNA
EXT-ANT
86LM (15') 86LMT (25')
External Antenna:
The external antenna can be used to increase the radio receiver range.
Antenna Extension Kit:
The antenna extension kit can be used with EXT-ANT for maximum radio receiver range.
CONTROL STATIONS
02-102
2-Button Control Station:
Steel enclosure.
02-103
OPEN
^
^
CLOSE
O
STOP
02-109
01-34215B © 2008, The Chamberlain Group, Inc. All Rights Reserved
3-Button Control Station:
Steel enclosure.
Key Control Station:
Indoor flush mount, NEMA 1.
WIRE
65-7WIREL
21-2LM
50-104-1
7 Conductor 20 AWG Wire (500'):
Recommended for control wiring.
2-Strand 22 AWG Wire (500'):
Color coded, white and white/black.
Coil Cord 18 AWG Wire (20'):
Black coil cord, 2 wire, 18 AWG, 20' extended.
Loading...