INSTALLATION MANUAL

Your model may look different than the model illustrated in this manual.
THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY.
Visit www.liftmaster.com to locate a professional installing dealer in your area.
This model is for use on vehicular passage gates ONLY and not intended for use on pedestrian passage gates.
This model is intended for use in Class I, II, III and IV vehicular swing gate applications.
UL325
compliant
UL991
compliant

TABLE OF CONTENTS

SAFETY 2
UL325 MODEL CLASSIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SAFETY INSTALLATION INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
GATE CONSTRUCTION INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
REQUIRED ENTRAPMENT PROTECTION DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . . 5
IMPORTANT SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
IMPORTANT SAFETY INFORMATION CONTINUED... . . . . . . . . . . . . . . . . . . . . . . . . 7
INTRODUCTION 8
OPERATOR SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
CARTON INVENTORY & OPERATOR DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . 8
FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
PREPARATION 10
SITE PREPARATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
PREPARATION 12
MOUNTING OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
INSTALLATION 13
MANUAL RELEASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
DETERMINE THE POSITION OF THE POST BRACKET . . . . . . . . . . . . . . . . . . . . . . . 13
DETERMINE THE POSITION OF THE GATE BRACKET . . . . . . . . . . . . . . . . . . . . . . . 14
WELD THE BRACKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
ATTACH THE OPERATOR TO THE BRACKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
STANDARD CONTROL BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
LARGE METAL CONTROL BOX (XLM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
WIRING 18
WIRE THE ENTRAPMENT PROTECTION DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . 18
EARTH GROUND ROD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
WIRE THE OPERATOR ARM TO THE CONTROL BOARD . . . . . . . . . . . . . . . . . . . . . 19
DUAL GATES ONLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
DUAL GATES ONLY CONTINUED... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
POWER WIRING INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
POWER WIRING (STANDARD CONTROL BOX) . . . . . . . . . . . . . . . . . . . . . . . . . . 22
POWER WIRING (LARGE METAL CONTROL BOX [XLM]) . . . . . . . . . . . . . . . . . . . 23
POWER WIRING (SOLAR PANELS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
POWER WIRING (SOLAR PANELS) CONTINUED... . . . . . . . . . . . . . . . . . . . . . . . . 25
ENGAGE THE OPERATOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
ADJUSTMENT 27
LIMIT AND FORCE ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
OBSTRUCTION TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
PROGRAMMING 29
REMOTE CONTROLS (NOT PROVIDED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
ERASE ALL CODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
OPERATION 30
MANUAL RELEASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
RESET BUTTON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
PARTY MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
OPERATOR ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
REMOTE CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
ADDITIONAL FEATURES 31
LIFTMASTER INTERNET GATEWAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
CONTROL BOARD OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
WIRING ACCESSORIES TO THE CONTROL BOARD . . . . . . . . . . . . . . . . . . . . . . . . 33
EXPANSION BOARD OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
WIRING ACCESSORIES TO THE EXPANSION BOARD . . . . . . . . . . . . . . . . . . . . . . 35
SAMS WIRING WITH RELAYS NOT ENERGIZED . . . . . . . . . . . . . . . . . . . . . . . . . . 36
GATE OPERATOR SETUP EXAMPLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
LIMIT SETUP WITH A REMOTE CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
MAINTENANCE 39
MAINTENANCE CHART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
BATTERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
TROUBLESHOOTING 40
CONTROL BOARD LEDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
LIMIT SETUP LEDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
CONTROL BOARD LEDS CONTINUED... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
TROUBLESHOOTING CHART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
REPAIR PARTS 45 WIRING DIAGRAMS 46 ACCESSORIES 48 WARRANTY 49

SAFETY

When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully.
When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your gate and/or the gate operator if you do not comply with the cautionary statements that accompany it. Read them carefully.
IMPORTANT NOTE
• BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions.
• DO NOT attempt repair or service of your gate operator unless you are an Authorized Service Technician.
SAFETY SYMBOL AND SIGNAL WORD REVIEW
MECHANICAL
ELECTRICAL
1
SAFETY
UL325 MODEL CLASSIFICATIONS
UL325 MODEL CLASSIFICATIONS
CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith.
CLASS II – COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units) hotel, garage, retail store or other building servicing the general public.
CLASS III – INDUSTRIAL/LIMITED ACCESS VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in a industrial location or building such as a factory or loading dock area or other location not intended to service the general public.
CLASS IV– RESTRICTED ACCESS VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
UL325 ENTRAPMENT PROTECTION REQUIREMENTS
This chart illustrates the entrapment protection requirements for the UL325 classes.
I
II
III
IV
GATE OPERATOR ENTRAPMENT PROTECTION
UL325 Classification Swing Gate Operator
Primary Type Secondary Type
CLASS I-CLASS IV A B1 or B2
In order to complete a proper installation you must satisfy the entrapment protection chart shown. That means that the installation must have one primary means of entrapment protection and one independent secondary means of entrapment protection. Both primary and secondary entrapment protection methods must be designed, arranged or configured to protect against entrapments in both the open and close directions of gate travel.
For Example: For a gate system that is installed on a single-family residence (UL325 Class I) you must provide the following: As your primary type of entrapment protection you must provide
• Type A - Inherent (built into the operator) entrapment sensing and at least one of the following as your secondary entrapment protection:
• Type B1 - Non-contact sensors such as photoelectric sensors,
• Type B2 - Contact sensors such as gate edges
NOTE: UL requires that all installations must have warning signs placed in plain view on both sides of the gate to warn pedestrians of the dangers of motorized gate systems.
2
SAFETY
SAFETY INSTALLATION INFORMATION
SAFETY INSTALLATION INFORMATION
1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application.
2. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application. Improperly designed, installed or maintained systems can create risks for the user as well as the bystander. Gate systems design and installation must reduce public exposure to potential hazards.
3. A gate operator can create high levels of force in its function as a component part of a gate system. Therefore, safety features must be incorporated into every design. Specific safety features include:
• Gate Edges • Guards for Exposed Rollers
• Photoelectric Sensors • Screen Mesh
• Vertical Posts • Instructional and Precautionary Signage
4. Install the gate operator only when:
a. The operator is appropriate for the construction and the usage class of the
gate.
b. All openings of a horizontal slide gate are guarded or screened from the
bottom of the gate to a minimum of 4 feet (1.2 m) above the ground to prevent a 2-1/4 inches (6 cm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.
c. All exposed pinch points are eliminated or guarded, and guarding is
supplied for exposed rollers.
5. The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
6. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
7. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
8. Controls intended for user activation must be located at least 6 feet (1.8 m) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use.
9. The Stop and/or Reset (if provided separately) must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start.
10. A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.
11. For a gate operator utilizing a non-contact sensor:
a. Reference owner’s manual regarding placement of non-contact sensor for
each type of application.
b. Care shall be exercised to reduce the risk of nuisance tripping, such as
when a vehicle trips the sensor while the gate is still moving.
c. One or more non-contact sensors shall be located where the risk of
entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier.
12. For a gate operator utilizing a contact sensor such as an edge sensor:
a. One or more contact sensors shall be located where the risk of
entrapment or obstruction exists, such as at the leading edge, trailing edge and post mounted both inside and outside of a vehicular horizontal slide gate.
b. One or more contact sensors shall be located at the bottom edge of a
vehicular vertical lift gate.
c. A hard wired contact sensor shall be located and its wiring arranged so
the communication between the sensor and the gate operator is not subject to mechanical damage.
d. A wireless contact sensor such as the one that transmits radio frequency
(RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.
e. One or more contact sensors shall be located on the inside and outside
leading edge of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge.
f. One or more contact sensors shall be located at the bottom edge of a
3
vertical barrier (arm).
SAFETY
GATE CONSTRUCTION INFORMATION
GATE CONSTRUCTION INFORMATION
Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at 610-832-9585 or www.astm.org.
1. GENERAL REQUIREMENTS
1.1 Gates shall be constructed in accordance with the provisions given for the appropriate gate type listed, refer to ASTM F2200 for additional gate types.
1.2 Gates shall be designed, constructed and installed to not fall over more than 45 degrees from the vertical plane, when a gate is detached from the supporting hardware.
1.3 Gates shall have smooth bottom edges, with vertical bottom edged protrusions not exceeding 0.50 inches (12.7 mm) when other than the exceptions listed in ASTM F2200.
1.4 The minimum height for barbed tape shall not be less than 8 feet (2.44 m) above grade and for barbed wire shall not be less than 6 feet (1.83 m) above grade.
1.5 An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator.
1.6 A gate latch shall not be installed on an automatically operated gate.
1.7 Protrusions shall not be permitted on any gate, refer to ASTM F2200 for Exceptions.
1.8 Gates shall be designed, constructed and installed such that their movement shall not be initiated by gravity when an automatic operator is disconnected.
1.9 A pedestrian gate shall not be incorporated into a vehicular gate panel or that portion of the adjacent fence that the gate covers in the open position.
3.1.3 A gap, measured in the horizontal plane parallel to the roadway, between a fixed stationary object nearest the roadway, (such as a gate support post) and the gate frame when the gate is in either the fully open position or the fully closed position, shall not exceed 2 1/4 inches (57 mm), refer to ASTM F2200 for Exception.
3.1.4 Positive stops shall be required to limit travel to the designed fully open and fully closed positions. These stops shall be installed at either the top of the gate, or at the bottom of the gate where such stops shall horizontally or vertically project no more than is required to perform their intended function.
3.1.5 All gates shall be designed with sufficient lateral stability to assure that the gate will enter a receiver guide, refer to ASTM F2200 for panel types.
3.2 The following provisions shall apply to Class IV vehicular horizontal slide gates:
3.2.1 All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade shall be guarded or covered.
3.2.2 Positive stops shall be required to limit travel to the designed fully open and fully closed positions. These stops shall be installed at either the top of the gate, or at the bottom of the gate where such stops shall horizontally or vertically project no more than is required to perform their intended function.
2. SPECIFIC APPLICATIONS
2.1 Any non-automated gate that is to be automated shall be upgraded to conform to the provisions of this specification.
2.2 This specification shall not apply to gates generally used for pedestrian access and to vehicular gates not to be automated.
2.3 Any existing automated gate, when the operator requires replacement, shall be upgraded to conform to the provisions of this specification in effect at that time.
3. VEHICULAR HORIZONTAL SLIDE GATES
3.1 The following provisions shall apply to Class I, Class II and Class III vehicular horizontal slide gates:
3.1.1 All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade shall be guarded or covered.
3.1.2 All openings located between 48 inches (1.22 m) and 72 inches (1.83 m) above grade shall be designed, guarded or screened to prevent a 4 inch (102 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that covers in the open position.
4. VEHICULAR HORIZONTAL SWING GATES
4.1 The following provisions shall apply to Class 1, Class II and Class III vehicular horizontal swing gates:
4.1.1 Gates shall be designed, constructed and installed so as not to create an entrapment area between the gate and the supporting structure or other fixed object when the gate moves toward the fully open position, subject to the provisions in the 4.1.1.1 and 4.1.1.2.
4.1.1.1 The width of an object (such as a wall, pillar or column) covered by a swing gate when in the open position shall not exceed 4 inches (102 mm), measured from the center line of the pivot point of the gate, refer to ASTM F2200 for exception.
4.1.1.2 Except for the zone specified in Section 4.1.1.1, the distance between a fixed object such as a wall, pillar or column, and a swing gate when in the open position shall not be less than 16 inches (406 mm), refer to ASTM F2200 for exception.
4.2 Class IV vehicular horizontal swing gates shall be designed, constructed and installed in accordance with security related parameters specific to the application in question.
4
SAFETY
REQUIRED ENTRAPMENT PROTECTION DEVICES
REQUIRED ENTRAPMENT PROTECTION DEVICES
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate.
• Locate entrapment protection devices to protect in BOTH the open and close gate cycles.
An entrapment zone is every location or point of contact where a person can become entrapped between a moving gate and a stationary object. All gate operator systems REQUIRE two independent entrapment protection systems for each entrapment zone. This operator contains an inherent (internal) entrapment protection system (the primary entrapment protection system) and REQUIRES the addition of an external entrapment protection system (non-contact photoelectric sensor or contact safety edge sensor) for EACH entrapment zone.
Your application may contain one or many entrapment zones. Property owners are obligated to test entrapment protection devices monthly.
CONTACT SENSORS (EDGE SENSORS)
If the electrically activated edge sensor comes in contact with an obstruction while the gate is moving, the gate will stop and reverse. The gate will not be able to travel in that direction until the obstruction is cleared. Use non monitored edge sensor models G65MG0204, G65MGR020, or G65MGS020.
3 Edge Contact Sensor
• Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls.
Edge Sensor for Open Cycle Edge Sensor for Close Cycle
NON-CONTACT SENSORS
If the photoelectric sensor beam gets blocked while the gate is moving, the gate will stop and reverse. The gate will not be able to travel in that direction until the obstruction is cleared. It is best to use monitored photoelectric sensors, model CPS-UN4. If a monitored photoelectric sensor is not working or loses power or the beam is blocked, then ALL gate operation in that direction will stop. Unmonitored photoelectric sensor models AOMRON and RETROAB are also acceptable.
Safety Non-Contact Sensor
Sensor for Open Cycle
Sensor for Close Cycle
5
SAFETY
IMPORTANT SAFETY INFORMATION
INSTALLATION
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Pinch points must be guarded at all times. Install enclosed-style gate tracks and roller guards.
• Place screen mesh 4 feet (1.2 m) high on the gate to prevent access through openings anywhere the gate may travel.
• Mount controls at least 6 feet (1.8 m) from the gate or ANY moving part of the gate.
• Install Warning signs on EACH side of gate in PLAIN VIEW. Permanently secure each Warning sign in a suitable manner using fastening holes.
• This operator is intended for vehicular use only. To prevent INJURY to pedestrians, a separate pedestrian access should be supplied, visible from the gate. Locate the pedestrian access where there is not a chance of INJURY at any point during full movement of the gate.
• Contact sensors MUST be located at the leading and trailing edges, and post mounted both inside and outside a horizontal swing gate. Non-contact sensors such as photo eyes MUST be mounted across the gate opening and operate during BOTH the open and close cycles.
IMPORTANT SAFETY INFORMATION
• Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate.
• Locate entrapment protection devices to protect in BOTH the open and close gate cycles.
• Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls.
• Too much force on gate will interfere with proper operation of safety reversal system.
• NEVER increase force beyond minimum amount required to move gate.
• NEVER use force adjustments to compensate for a binding or sticking gate.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested. Gate MUST reverse on contact with a rigid object.
• DO NOT touch the heater when switch is on, heater may be hot.
• To AVOID damaging gas, power or other underground utility lines, contact underground utility locating companies BEFORE digging more than 18 inches (46 cm) deep.
WIRING
To reduce the risk of SEVERE INJURY or DEATH:
• ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power (AC or solar and battery) and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service.
• Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with national and local electrical codes. NOTE: The operator should be on a separate fused line of
adequate capacity.
ADJUSTMENT
To reduce the risk of SEVERE INJURY or DEATH:
• Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a moving gate.
• Too much force on gate will interfere with proper operation of safety reversal system.
• NEVER increase force beyond minimum amount required to move gate.
• ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment.
• ALL electrical connections MUST be made by a qualified individual.
• DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram. We recommend that you install an edge sensor BEFORE proceeding with the control station installation.
• ALL power wiring should be on a dedicated circuit and well protected. The location of the power disconnect should be visible and clearly labeled.
• ALL power and control wiring MUST be run in separate conduit.
• NEVER use force adjustments to compensate for a binding or sticking gate.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested. Gate MUST reverse on contact with a rigid object.
6
SAFETY
IMPORTANT SAFETY INFORMATION CONTINUED...
ADDITIONAL FEATURES
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate.
• Locate entrapment protection devices to protect in BOTH the open and close gate cycles.
MAINTENANCE AND OPERATION
To reduce the risk of SEVERE INJURY or DEATH:
• READ AND FOLLOW ALL INSTRUCTIONS.
• ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power (AC or solar and battery) and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service.
• Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with national and local electrical codes. NOTE: The operator should be on a separate fused line of
adequate capacity.
• NEVER let children operate or play with gate controls. Keep the remote control away from children.
• ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
• The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance.
• Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls.
• Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or reverse when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of INJURY or DEATH.
• Use the manual disconnect release ONLY when the gate is not moving.
• KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person make repairs to gate hardware.
• ALL maintenance MUST be performed by a LiftMaster professional.
• Activate gate ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to gate travel.
• To reduce the risk of FIRE or INJURY to persons use ONLY LiftMaster part 29-NP712 for replacement batteries.
• SAVE THESE INSTRUCTIONS.
IMPORTANT SAFETY INFORMATION
• ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment.
TROUBLESHOOTING
To protect against fire and electrocution:
• DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator.
For continued protection against fire:
• Replace ONLY with fuse of same type and rating.
7

INTRODUCTION

OPERATOR SPECIFICATIONS
This model is intended for use in vehicular swing gate applications:
OPERATOR SPECIFICATIONS + CARTON INVENTORY & OPERATOR DIMENSIONS
Gate Classifications: CLASS I, II, III, & IV Main AC Supply: 120 Vac or 240 Vac (240 Vac option with Toroid Kit ONLY)
Solar Power Max: 24 Vdc at 60 watts max. Input Rating: 8 Amps at 120 Vac or 1 Amp at 240 Vac Input Rating Excluding Accessory Outlets: 2 Amps at 120 Vac or 1
Amp at 240 Vac
*Input Rating of Accessory Outlets:
*NOTE: The accessory outlets are not connected for the 240 Vac rating. Main Supply (Motor): 24 Vdc
Accessory Power: 24 Vdc 500 mA Max for ON or SW (switched)
NOTE: Increased accessory power drawn from the operator will reduce solar performance (solar applications ONLY).
Full Cycle Time: 32 seconds (90 degree opening) Maximum Travel Range: 115 degrees
6 Amps at 120 Vac
Maximum Gate Weight/Length:
• 1600 lbs./8 foot
• 800 lbs./16 foot
• 600 lbs./18 foot
Ambient Temperature: -40°C to 60°C (-40°F to 140°F) Fuse Protection Battery: 30 Amp Fuse Protection DC Power: 30 Amp Daily cycle rate: 300 cycles/day
Optional toroid transformer kit:
120/240 Vac Operation Cold Weather Applications: -4°F for extended periods AC powered direct from toroid: Batteries are used for backup only.
CARTON INVENTORY & OPERATOR DIMENSIONS
NOT SHOWN: Documentation Packet, Hardware Bag
Reduces the need for battery service.
5.83" (14.8 cm)
Operator Model LA500 (1) Model LA500-S (2)
Key (2)
Terminal Block
Connector
4.21" (10.7 cm)
40.35" (102.5 cm)
Junction Box
MODEL LA500-S ONLY
Extension Cable
Post Bracket
Watertight Connector (2)
Gate Bracket
Warning Signs (2) and Warranty Card
OR
Standard Control Box with Batteries 12 Vdc 7AH (2)
Large Metal Control Box (XLM), ordered separately (batteries not included)
8
INTRODUCTION
FEATURES
OPERATOR FEATURES
• Advanced “Centerpiece” Control Board
• 120 Vac Power Input (standard)
- Optional Input Selection: 120 Vac (factory setting) or 240 Vac (Field change, optional toroid kit with AC Surge Protection and EMI Filter Board. Refer to accessory page.)
• Long life DC motor
• AC powered with integrated EverCharge® Power Management System
• 24 Vdc accessory power
CONTROL BOARD FEATURES
• Electronic Limit adjustment and control
• Adjustable reversal force
• Adjustable Timer-to-Close (TTC)
• Maximum Run Timer
• Bipart Delay switch (dual gate applications)
• Feedback and Diagnostic LEDs
• Integrated Radio Receiver, Single Button Control (SBC) and 3-Button Station control, four radio frequencies supporting Security 2.0™
FEATURES
• Programmable with up to 50 remote controls and 2 keyless entries. Compatible
• SAMS compatible
• Slow-start and slow-stop gate motion
• Reset Button
• Audible Alarm
• Electronic limit adjustment and control from the remote control
• Lockable manual release handle
• COMMANDS:
- OPEN, CLOSE, or STOP: accessory connection and on-board button
- Single Button Close (SBC): accessory connection
- FIRE DEPARTMENT OPEN: accessory connection
- INTEGRATED RADIO RECEIVER
• LOOPS:
- EXIT, SHADOW, or INTERRUPT LOOP: accessory connection
with MyQ 433 MHz
®
devices and Security 2.0™ codes at either 310, 315, 390 MHz, or
EXPANSION BOARD FEATURES
• Plug-in Loop Detector Connectors (Model LOOPDETLM Loop Detector)
- SHADOW
- INTERRUPT
- EXIT, with Fail Open/Fail Close selection
• Quick-Close ON/OFF selection switch
• AC Fail Open/Battery selection switch
• Low Battery Open/Close selection switch
• Anti-Tail ON/OFF selection switch
• Single Button Control (SBC) accessory connection
• 3-Button station accessory connection
• AUX Relays (2) each independently selectable operation:
- OPEN LIMIT: ON at open limit switch
- CLOSE LIMIT: OFF at close limit switch
- GATE MOVING: ON with gate moving
- PRE-ALERT DELAY: ON 3 seconds before gate motion, option of using the onboard alarm.
- TAMPER: ON when gate manually pulled from close limit, option of using the external buzzer through AUX relay 1 or 2 on expansion board.
- POWER: ON with AC or Solar power available
- CYCLE QUANTITY: LEDs blink operational cycle count
9

PREPARATION

SITE PREPARATION
Check the national and local building codes BEFORE installation.
SAFETY
Entrapment protection devices are required to protect against any entrapment or safety conditions encountered in your gate application (refer to page 5 for more details). Install warning signs on both sides of the gate.
!
!
Warning Signs
Entrapment Danger
VEHICLE LOOPS
The vehicle loops allow the gate to stay open when vehicles are obstructing the gate path. Suggested for vehicles 14 feet (4.27 m) or longer. Vehicle loops are not required but are recommended.
(Inside Property)
GATE
Gate must be constructed and installed according to ASTM F2200 standards (refer to page 4). Gate must fit specifications of operator (refer to specifications).
EARTH GROUND ROD
Proper grounding gives an electrical charge, such as from an electrical static discharge or a near lightning strike, a path from which to dissipate its energy safely into the earth. Without this path, the intense energy generated by lightning could be directed towards the gate operator. Although nothing can absorb the tremendous power of a direct lightning strike, proper grounding can protect the gate operator in most cases.
CONDUIT
Conduit must be UL approved for low and high voltage.
Check national and local codes for proper depth
10
Conduit
INSTALLATION TYPES
Identify your installation type. The installation steps in this manual will show a typical Pull-to-Open application.
SITE PREPARATION
10" Minimum
NOTE: Weld Rebar Behind Gate Hinges for Maximum Strength.
Column Install
PULL-TO-OPEN
Gate Hinge
Heavy Steel Plate for Reinforcement (Not provided)
Heavy Steel Bracket (Reinforce if necessary)
Back Steel Bracket (Reinforce if necessary)
Gate Hinge
Post Install
Gate Hinge
Back Steel Plates for Reinforcement (Not provided)
Gate Hinge
NOTE: Weld Rebar Behind Gate Hinges for Maximum Strength.
Column Install
PUSH-TO-OPEN
Gate Hinge
Heavy Steel Plate for Reinforcement (Not provided)
Back Steel Bracket (Reinforce if necessary)
Gate Hinge
Post Install
Gate Hinge
Gate Hinge
Control Box
Water Tight Conduit (Not provided)
Top View
Operator
Earth Ground Rod
SINGLE GATE
!
Heavy Steel Plate for Reinforcement (Not provided)
Control Box
Primary Operator
Earth Ground Rod
Top View
DUAL GATE
!
Water Tight Conduit (Not provided)
Secondary Operator
!
Junction Box
Shielded low voltage wires.
11
PREPARATION
!
!
!
!
!
MOUNTING OPTIONS
MOUNTING DO's
MOUNTING OPTIONS
Weld a horizontal bar across entire gate on any installation for strength. Make sure that the operator is mounted level or it will not function properly.
MOUNTING DON'Ts
An off-level installation may cause the gate or operator to fail prematurely.
The operator can be mounted on top of the gate frame.
DO NOT weld the crossbar on just a few pickets, or they could bend.
DO NOT install upside down.
DO NOT install on ANY pedestrian passageways, doorways, or gates.
DO NOT install on uphill or downhill gates.
DO NOT install next to sprinklers or any area that may expose the bottom of operator to water.
12
DO NOT over-bend the cord from the operator. Doing this will cause the wires to eventually break.

INSTALLATION

MANUAL RELEASE + DETERMINE THE POSITION OF THE POST BRACKET
MANUAL RELEASE
Insert the key into the lock and turn it 180 degrees counterclockwise.
1
Turn the release lever 180 degrees counterclockwise. The operator is now in
2
manual mode.
If this operator is a replacement for a Miracle-One™ operator, use the existing post bracket and gate bracket. Remove the Miracle-One™ operator from the brackets and proceed to page 15.
DETERMINE THE POSITION OF THE POST BRACKET
The measurements shown below are typical for a standard installation. Your installation may be different. For optimal mechanical advantage the measurement for A must be larger than the measurement for B.
Close the gate.
1
Choose a vertical mounting location for the post bracket.
2
Place a measuring tape under the center of the gate hinge point and measure
3
out 8-1/2 inches (A).
Use a screwdriver or dowel rod to temporarily mark the location of the first
4
measurement.
Measure 7-3/4 inches (B) from the previous mark.
5
Use a screwdriver to mark the location of the second measurement.
6
Align the post bracket as close as possible above the screwdriver or dowel rod
7
and tack weld the post bracket in the desired vertical position.
If your application is Push-to-Open, refer to the illustration to the right.
Alternative A & B dimensions
ABCD
8-1/2" 7-3/4" 35-1/2" 6-1/2" 7-3/4" 8-1/2" 35-1/2" 6-1/2"
9" 9" 35-1/2" 6-1/2" 9" 8-1/2" 35-1/2" 6-1/2"
7-1/2" 7-1/2" 35-1/2" 6-1/2"
8-1/2" (A)
7-3/4" (B)
8-1/2" (A)
7-3/4" (B)
Post Bracket Location
PUSH-TO-OPEN
8-1/2"
7-3/4"
13
INSTALLATION
DETERMINE THE POSITION OF THE GATE BRACKET + WELD THE BRACKETS
DETERMINE THE POSITION OF THE GATE BRACKET
The gate bracket MUST be installed in an area that can withstand heavy forces. Additional reinforcement steel plates may be necessary for mounting.
Position a level on the post bracket and measure 35-1/2 inches over from the
1
center hole of the post bracket and mark the location on the gate.
Measure 2-1/4 inches down from the previous mark and center the bracket on
2
this mark. Tack weld the gate bracket in this position.
NOTE: While the gate is in the fully open position, the operator needs a clearance of 10-1/4 inches as shown.
Outside Property
6-1/2" (D)
PUSH-TO-OPEN
35-1/2" (C)
Gate Bracket Location
35-1/2"
10-1/4"
Inside Property
WELD THE BRACKETS
Position the operator on the brackets and make sure the operator is level and
1
positioned correctly on the gate.
2-1/4"
Remove the operator from the gate.
2
Completely weld around the post bracket and gate bracket.
3
NOTE: Brackets may need additional reinforcement by welding flat stock as shown.
14