SAFETY
When you see these Safety Symbols and Signal Words on the following pages, they
will alert you to the possibility of serious injury or death if you do not comply with
the warnings that accompany them. The hazard may come from something
mechanical or from electric shock. Read the warnings carefully.
When you see this Signal Word on the following pages, it will alert you to the
possibility of damage to your gate and/or the gate operator if you do not comply
with the cautionary statements that accompany it. Read them carefully.
IMPORTANT NOTE
• BEFORE attempting to install, operate or maintain the operator, you must read
and fully understand this manual and follow all safety instructions.
• DO NOT attempt repair or service of your gate operator unless you are an
Authorized Service Technician.
SAFETY SYMBOL AND SIGNAL WORD REVIEW
MECHANICAL
ELECTRICAL
1
SAFETY
UL325 MODEL CLASSIFICATIONS
UL325 MODEL CLASSIFICATIONS
CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in a home of one-to four
single family dwellings, or a garage or parking area associated therewith.
CLASS II – COMMERCIAL/GENERAL ACCESS VEHICULAR
GATE OPERATOR
A vehicular gate operator (or system) intended for use in a commercial location or
building such as a multi-family housing unit (five or more single family units) hotel,
garage, retail store or other building servicing the general public.
CLASS III – INDUSTRIAL/LIMITED ACCESS VEHICULAR
GATE OPERATOR
A vehicular gate operator (or system) intended for use in a industrial location or
building such as a factory or loading dock area or other location not intended to
service the general public.
CLASS IV– RESTRICTED ACCESS VEHICULAR GATE
OPERATOR
A vehicular gate operator (or system) intended for use in a guarded industrial
location or building such as an airport security area or other restricted access
locations not servicing the general public, in which unauthorized access is prevented
via supervision by security personnel.
UL325 ENTRAPMENT PROTECTION REQUIREMENTS
This chart illustrates the entrapment protection requirements for the UL325 classes.
I
II
III
IV
GATE OPERATOR ENTRAPMENT PROTECTION
UL325 ClassificationSwing Gate Operator
Primary TypeSecondary Type
CLASS I-CLASS IVAB1 or B2
In order to complete a proper installation you must satisfy the entrapment
protection chart shown. That means that the installation must have one primary
means of entrapment protection and one independent secondary means of
entrapment protection. Both primary and secondary entrapment protection
methods must be designed, arranged or configured to protect against
entrapments in both the open and close directions of gate travel.
For Example: For a gate system that is installed on a single-family residence
(UL325 Class I) you must provide the following: As your primary type of
entrapment protection you must provide
• Type A - Inherent (built into the operator) entrapment sensing and at
least one of the following as your secondary entrapment
protection:
• Type B1 - Non-contact sensors such as photoelectric sensors,
• Type B2 - Contact sensors such as gate edges
NOTE: UL requires that all installations must have warning signs placed in plain
view on both sides of the gate to warn pedestrians of the dangers of motorized gate
systems.
2
SAFETY
SAFETY INSTALLATION INFORMATION
SAFETY INSTALLATION INFORMATION
1. Vehicular gate systems provide convenience and security. Gate systems are
comprised of many component parts. The gate operator is only one
component. Each gate system is specifically designed for an individual
application.
2. Gate operating system designers, installers and users must take into account
the possible hazards associated with each individual application. Improperly
designed, installed or maintained systems can create risks for the user as
well as the bystander. Gate systems design and installation must reduce
public exposure to potential hazards.
3. A gate operator can create high levels of force in its function as a component
part of a gate system. Therefore, safety features must be incorporated into
every design. Specific safety features include:
• Gate Edges • Guards for Exposed Rollers
• Photoelectric Sensors • Screen Mesh
• Vertical Posts • Instructional and Precautionary Signage
4. Install the gate operator only when:
a. The operator is appropriate for the construction and the usage class of the
gate.
b. All openings of a horizontal slide gate are guarded or screened from the
bottom of the gate to a minimum of 4 feet (1.2 m) above the ground to
prevent a 2-1/4 inches (6 cm) diameter sphere from passing through the
openings anywhere in the gate, and in that portion of the adjacent fence
that the gate covers in the open position.
c. All exposed pinch points are eliminated or guarded, and guarding is
supplied for exposed rollers.
5. The operator is intended for installation only on gates used for vehicles.
Pedestrians must be supplied with a separate access opening. The pedestrian
access opening shall be designed to promote pedestrian usage. Locate the
gate such that persons will not come in contact with the vehicular gate during
the entire path of travel of the vehicular gate.
6. The gate must be installed in a location so that enough clearance is supplied
between the gate and adjacent structures when opening and closing to reduce
the risk of entrapment. Swinging gates shall not open into public access
areas.
7. The gate must be properly installed and work freely in both directions prior
to the installation of the gate operator.
8. Controls intended for user activation must be located at least 6 feet (1.8 m)
away from any moving part of the gate and where the user is prevented
from reaching over, under, around or through the gate to operate the
controls. Outdoor or easily accessible controls shall have a security feature to
prevent unauthorized use.
9. The Stop and/or Reset (if provided separately) must be located in the
line-of-sight of the gate. Activation of the reset control shall not cause the
operator to start.
10. A minimum of two (2) WARNING SIGNS shall be installed, one on each side
of the gate where easily visible.
11. For a gate operator utilizing a non-contact sensor:
a. Reference owner’s manual regarding placement of non-contact sensor for
each type of application.
b. Care shall be exercised to reduce the risk of nuisance tripping, such as
when a vehicle trips the sensor while the gate is still moving.
c. One or more non-contact sensors shall be located where the risk of
entrapment or obstruction exists, such as the perimeter reachable by a
moving gate or barrier.
12. For a gate operator utilizing a contact sensor such as an edge sensor:
a. One or more contact sensors shall be located where the risk of
entrapment or obstruction exists, such as at the leading edge, trailing
edge and post mounted both inside and outside of a vehicular horizontal
slide gate.
b. One or more contact sensors shall be located at the bottom edge of a
vehicular vertical lift gate.
c. A hard wired contact sensor shall be located and its wiring arranged so
the communication between the sensor and the gate operator is not
subject to mechanical damage.
d. A wireless contact sensor such as the one that transmits radio frequency
(RF) signals to the gate operator for entrapment protection functions shall
be located where the transmission of the signals are not obstructed or
impeded by building structures, natural landscaping or similar obstruction.
A wireless contact sensor shall function under the intended end-use
conditions.
e. One or more contact sensors shall be located on the inside and outside
leading edge of a swing gate. Additionally, if the bottom edge of a swing
gate is greater than 6 inches (152 mm) above the ground at any point in
its arc of travel, one or more contact sensors shall be located on the
bottom edge.
f. One or more contact sensors shall be located at the bottom edge of a
3
vertical barrier (arm).
SAFETY
GATE CONSTRUCTION INFORMATION
GATE CONSTRUCTION INFORMATION
Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at
610-832-9585 or www.astm.org.
1. GENERAL REQUIREMENTS
1.1 Gates shall be constructed in accordance with the provisions given for the
appropriate gate type listed, refer to ASTM F2200 for additional gate types.
1.2 Gates shall be designed, constructed and installed to not fall over more than
45 degrees from the vertical plane, when a gate is detached from the
supporting hardware.
1.3 Gates shall have smooth bottom edges, with vertical bottom edged
protrusions not exceeding 0.50 inches (12.7 mm) when other than the
exceptions listed in ASTM F2200.
1.4 The minimum height for barbed tape shall not be less than 8 feet (2.44 m)
above grade and for barbed wire shall not be less than 6 feet (1.83 m)
above grade.
1.5 An existing gate latch shall be disabled when a manually operated gate is
retrofitted with a powered gate operator.
1.6 A gate latch shall not be installed on an automatically operated gate.
1.7 Protrusions shall not be permitted on any gate, refer to ASTM F2200 for
Exceptions.
1.8 Gates shall be designed, constructed and installed such that their movement
shall not be initiated by gravity when an automatic operator is disconnected.
1.9 A pedestrian gate shall not be incorporated into a vehicular gate panel or
that portion of the adjacent fence that the gate covers in the open position.
3.1.3 A gap, measured in the horizontal plane parallel to the roadway, between a
fixed stationary object nearest the roadway, (such as a gate support post)
and the gate frame when the gate is in either the fully open position or the
fully closed position, shall not exceed 2 1/4 inches (57 mm), refer to ASTM
F2200 for Exception.
3.1.4 Positive stops shall be required to limit travel to the designed fully open and
fully closed positions. These stops shall be installed at either the top of the
gate, or at the bottom of the gate where such stops shall horizontally or
vertically project no more than is required to perform their intended
function.
3.1.5 All gates shall be designed with sufficient lateral stability to assure that the
gate will enter a receiver guide, refer to ASTM F2200 for panel types.
3.2 The following provisions shall apply to Class IV vehicular horizontal slide
gates:
3.2.1 All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade
shall be guarded or covered.
3.2.2 Positive stops shall be required to limit travel to the designed fully open and
fully closed positions. These stops shall be installed at either the top of the
gate, or at the bottom of the gate where such stops shall horizontally or
vertically project no more than is required to perform their intended
function.
2. SPECIFIC APPLICATIONS
2.1 Any non-automated gate that is to be automated shall be upgraded to
conform to the provisions of this specification.
2.2 This specification shall not apply to gates generally used for pedestrian
access and to vehicular gates not to be automated.
2.3 Any existing automated gate, when the operator requires replacement, shall
be upgraded to conform to the provisions of this specification in effect at
that time.
3. VEHICULAR HORIZONTAL SLIDE GATES
3.1 The following provisions shall apply to Class I, Class II and Class III vehicular
horizontal slide gates:
3.1.1 All weight bearing exposed rollers 8 feet (2.44 m), or less, above grade
shall be guarded or covered.
3.1.2 All openings located between 48 inches (1.22 m) and 72 inches (1.83 m)
above grade shall be designed, guarded or screened to prevent a 4 inch
(102 mm) diameter sphere from passing through the openings anywhere in
the gate, and in that portion of the adjacent fence that covers in the open
position.
4. VEHICULAR HORIZONTAL SWING GATES
4.1 The following provisions shall apply to Class 1, Class II and Class III vehicular
horizontal swing gates:
4.1.1 Gates shall be designed, constructed and installed so as not to create an
entrapment area between the gate and the supporting structure or other
fixed object when the gate moves toward the fully open position, subject to
the provisions in the 4.1.1.1 and 4.1.1.2.
4.1.1.1 The width of an object (such as a wall, pillar or column) covered by a swing
gate when in the open position shall not exceed 4 inches (102 mm),
measured from the center line of the pivot point of the gate, refer to ASTM
F2200 for exception.
4.1.1.2 Except for the zone specified in Section 4.1.1.1, the distance between a
fixed object such as a wall, pillar or column, and a swing gate when in the
open position shall not be less than 16 inches (406 mm), refer to ASTM
F2200 for exception.
4.2 Class IV vehicular horizontal swing gates shall be designed, constructed and
installed in accordance with security related parameters specific to the
application in question.
4
SAFETY
REQUIRED ENTRAPMENT PROTECTION DEVICES
REQUIRED ENTRAPMENT PROTECTION DEVICES
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Entrapment protection devices MUST be installed to protect anyone who may
come near a moving gate.
• Locate entrapment protection devices to protect in BOTH the open and close
gate cycles.
An entrapment zone is every location or point of contact where a person can become entrapped between a moving gate and a stationary object. All gate operator systems
REQUIRE two independent entrapment protection systems for each entrapment zone. This operator contains an inherent (internal) entrapment protection system (the primary
entrapment protection system) and REQUIRES the addition of an external entrapment protection system (non-contact photoelectric sensor or contact safety edge sensor) for
EACH entrapment zone.
Your application may contain one or many entrapment zones. Property owners are obligated to test entrapment protection devices monthly.
CONTACT SENSORS (EDGE SENSORS)
If the electrically activated edge sensor comes in contact with an obstruction while the gate is moving, the gate will stop and reverse. The gate will not be able to travel in that
direction until the obstruction is cleared. Use non monitored edge sensor models G65MG0204, G65MGR020, or G65MGS020.
3 Edge Contact Sensor
• Locate entrapment protection devices to protect between moving gate and
RIGID objects, such as posts or walls.
Edge Sensor for Open CycleEdge Sensor for Close Cycle
NON-CONTACT SENSORS
If the photoelectric sensor beam gets blocked while the gate is moving, the gate will stop and reverse. The gate will not be able to travel in that direction until the obstruction
is cleared. It is best to use monitored photoelectric sensors, model CPS-UN4. If a monitored photoelectric sensor is not working or loses power or the beam is blocked, then ALL
gate operation in that direction will stop. Unmonitored photoelectric sensor models AOMRON and RETROAB are also acceptable.
Safety Non-Contact Sensor
Sensor for Open Cycle
Sensor for Close Cycle
5
SAFETY
IMPORTANT SAFETY INFORMATION
INSTALLATION
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Pinch points must be guarded at all times. Install enclosed-style gate tracks and
roller guards.
• Place screen mesh 4 feet (1.2 m) high on the gate to prevent access through
openings anywhere the gate may travel.
• Mount controls at least 6 feet (1.8 m) from the gate or ANY moving part of the
gate.
• Install Warning signs on EACH side of gate in PLAIN VIEW. Permanently secure
each Warning sign in a suitable manner using fastening holes.
• This operator is intended for vehicular use only. To prevent INJURY to
pedestrians, a separate pedestrian access should be supplied, visible from the
gate. Locate the pedestrian access where there is not a chance of INJURY at any
point during full movement of the gate.
• Contact sensors MUST be located at the leading and trailing edges, and post
mounted both inside and outside a horizontal swing gate. Non-contact sensors
such as photo eyes MUST be mounted across the gate opening and operate
during BOTH the open and close cycles.
IMPORTANT SAFETY INFORMATION
• Entrapment protection devices MUST be installed to protect anyone who may
come near a moving gate.
• Locate entrapment protection devices to protect in BOTH the open and close
gate cycles.
• Locate entrapment protection devices to protect between moving gate and RIGID
objects, such as posts or walls.
• Too much force on gate will interfere with proper operation of safety reversal
system.
• NEVER increase force beyond minimum amount required to move gate.
• NEVER use force adjustments to compensate for a binding or sticking gate.
• If one control (force or travel limits) is adjusted, the other control may also
need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested.
Gate MUST reverse on contact with a rigid object.
• DO NOT touch the heater when switch is on, heater may be hot.
• To AVOID damaging gas, power or other underground utility lines, contact
underground utility locating companies BEFORE digging more than 18 inches
(46 cm) deep.
WIRING
To reduce the risk of SEVERE INJURY or DEATH:
• ANY maintenance to the operator or in the area near the operator MUST NOT
be performed until disconnecting the electrical power (AC or solar and battery)
and locking-out the power via the operator power switch. Upon completion of
maintenance the area MUST be cleared and secured, at that time the unit may
be returned to service.
• Disconnect power at the fuse box BEFORE proceeding. Operator MUST be
properly grounded and connected in accordance with national and local
electrical codes. NOTE:The operator should be on a separate fused line of
adequate capacity.
ADJUSTMENT
To reduce the risk of SEVERE INJURY or DEATH:
• Without a properly installed safety reversal system, persons (particularly small
children) could be SERIOUSLY INJURED or KILLED by a moving gate.
• Too much force on gate will interfere with proper operation of safety reversal
system.
• NEVER increase force beyond minimum amount required to move gate.
• ALWAYS wear protective gloves and eye protection when changing the battery
or working around the battery compartment.
• ALL electrical connections MUST be made by a qualified individual.
• DO NOT install ANY wiring or attempt to run the operator without consulting the
wiring diagram. We recommend that you install an edge sensor BEFORE
proceeding with the control station installation.
• ALL power wiring should be on a dedicated circuit and well protected. The
location of the power disconnect should be visible and clearly labeled.
• ALL power and control wiring MUST be run in separate conduit.
• NEVER use force adjustments to compensate for a binding or sticking gate.
• If one control (force or travel limits) is adjusted, the other control may also
need adjustment.
• After ANY adjustments are made, the safety reversal system MUST be tested.
Gate MUST reverse on contact with a rigid object.
6
SAFETY
IMPORTANT SAFETY INFORMATION CONTINUED...
ADDITIONAL FEATURES
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Entrapment protection devices MUST be installed to protect anyone who may
come near a moving gate.
• Locate entrapment protection devices to protect in BOTH the open and close
gate cycles.
MAINTENANCE AND OPERATION
To reduce the risk of SEVERE INJURY or DEATH:
• READ AND FOLLOW ALL INSTRUCTIONS.
• ANY maintenance to the operator or in the area near the operator MUST NOT
be performed until disconnecting the electrical power (AC or solar and battery)
and locking-out the power via the operator power switch. Upon completion of
maintenance the area MUST be cleared and secured, at that time the unit may
be returned to service.
• Disconnect power at the fuse box BEFORE proceeding. Operator MUST be
properly grounded and connected in accordance with national and local
electrical codes. NOTE:The operator should be on a separate fused line of
adequate capacity.
• NEVER let children operate or play with gate controls. Keep the remote control
away from children.
• ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS
THE PATH OF THE MOVING GATE.
• The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance.
• Locate entrapment protection devices to protect between moving gate and RIGID
objects, such as posts or walls.
• Test the gate operator monthly. The gate MUST reverse on contact with a rigid
object or reverse when an object activates the non-contact sensors. After
adjusting the force or the limit of travel, retest the gate operator. Failure to
adjust and retest the gate operator properly can increase the risk of INJURY or
DEATH.
• Use the manual disconnect release ONLY when the gate is not moving.
• KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a
qualified service person make repairs to gate hardware.
• ALL maintenance MUST be performed by a LiftMaster professional.
• Activate gate ONLY when it can be seen clearly, is properly adjusted and there
are no obstructions to gate travel.
• To reduce the risk of FIRE or INJURY to persons use ONLY LiftMaster part
29-NP712 for replacement batteries.
• SAVE THESE INSTRUCTIONS.
IMPORTANT SAFETY INFORMATION
• ALWAYS wear protective gloves and eye protection when changing the battery
or working around the battery compartment.
TROUBLESHOOTING
To protect against fire and electrocution:
• DISCONNECT power (AC or solar and battery) BEFORE installing or servicing
operator.
For continued protection against fire:
• Replace ONLY with fuse of same type and rating.
7
INTRODUCTION
OPERATOR SPECIFICATIONS
This model is intended for use in vehicular swing gate applications:
Gate Classifications: CLASS I, II, III, & IV
Main AC Supply: 120 Vac or 240 Vac (240 Vac option with Toroid Kit ONLY)
Solar Power Max: 24 Vdc at 60 watts max.
Input Rating: 8 Amps at 120 Vac or 1 Amp at 240 Vac
Input Rating Excluding Accessory Outlets: 2 Amps at 120 Vac or 1
Amp at 240 Vac
*Input Rating of Accessory Outlets:
*NOTE: The accessory outlets are not connected for the 240 Vac rating.
Main Supply (Motor): 24 Vdc
Accessory Power: 24 Vdc 500 mA Max for ON or SW (switched)
NOTE: Increased accessory power drawn from the operator will reduce solar
performance (solar applications ONLY).
Full Cycle Time: 32 seconds (90 degree opening)
Maximum Travel Range: 115 degrees
6 Amps at 120 Vac
Maximum Gate Weight/Length:
• 1600 lbs./8 foot
• 800 lbs./16 foot
• 600 lbs./18 foot
Ambient Temperature: -40°C to 60°C (-40°F to 140°F)
Fuse Protection Battery: 30 Amp
Fuse Protection DC Power: 30 Amp
Daily cycle rate: 300 cycles/day
Optional toroid transformer kit:
120/240 Vac Operation
Cold Weather Applications: -4°F for extended periods
AC powered direct from toroid: Batteries are used for backup only.
CARTON INVENTORY & OPERATOR DIMENSIONS
NOT SHOWN: Documentation Packet, Hardware Bag
Reduces the need for battery service.
5.83" (14.8 cm)
Operator
Model LA500 (1)
Model LA500-S (2)
Key (2)
Terminal Block
Connector
4.21" (10.7 cm)
40.35" (102.5 cm)
Junction Box
MODEL LA500-S ONLY
Extension Cable
Post Bracket
Watertight Connector (2)
Gate Bracket
Warning Signs (2) and Warranty Card
OR
Standard Control Box with
Batteries 12 Vdc 7AH (2)
Large Metal Control Box (XLM),
ordered separately (batteries
not included)
8
INTRODUCTION
FEATURES
OPERATOR FEATURES
• Advanced “Centerpiece” Control Board
• 120 Vac Power Input (standard)
- Optional Input Selection: 120 Vac (factory setting) or 240 Vac (Field change,
optional toroid kit with AC Surge Protection and EMI Filter Board. Refer to
accessory page.)
• Long life DC motor
• AC powered with integrated EverCharge® Power Management System
• 24 Vdc accessory power
CONTROL BOARD FEATURES
• Electronic Limit adjustment and control
• Adjustable reversal force
• Adjustable Timer-to-Close (TTC)
• Maximum Run Timer
• Bipart Delay switch (dual gate applications)
• Feedback and Diagnostic LEDs
• Integrated Radio Receiver, Single Button Control (SBC) and 3-Button Station
control, four radio frequencies supporting Security✚ 2.0™
FEATURES
• Programmable with up to 50 remote controls and 2 keyless entries. Compatible
• SAMS compatible
• Slow-start and slow-stop gate motion
• Reset Button
• Audible Alarm
• Electronic limit adjustment and control from the remote control
• Lockable manual release handle
• COMMANDS:
- OPEN, CLOSE, or STOP: accessory connection and on-board button
- Single Button Close (SBC): accessory connection
- FIRE DEPARTMENT OPEN: accessory connection
- INTEGRATED RADIO RECEIVER
• LOOPS:
- EXIT, SHADOW, or INTERRUPT LOOP: accessory connection
with MyQ
433 MHz
®
devices and Security✚ 2.0™ codes at either 310, 315, 390 MHz, or
Check the national and local building codes BEFORE installation.
SAFETY
Entrapment protection devices are required to protect against any entrapment
or safety conditions encountered in your gate application (refer to page 5
for more details). Install warning signs on both sides of the gate.
!
!
Warning Signs
Entrapment Danger
VEHICLE LOOPS
The vehicle loops allow the gate to stay open when vehicles are obstructing the
gate path. Suggested for vehicles 14 feet (4.27 m) or longer. Vehicle loops are
not required but are recommended.
(Inside Property)
GATE
Gate must be constructed and installed according to ASTM F2200 standards
(refer to page 4). Gate must fit specifications of operator (refer to
specifications).
EARTH GROUND ROD
Proper grounding gives an electrical
charge, such as from an electrical
static discharge or a near lightning
strike, a path from which to dissipate
its energy safely into the earth.
Without this path, the intense energy
generated by lightning could be
directed towards the gate operator.
Although nothing can absorb the
tremendous power of a direct lightning
strike, proper grounding can protect
the gate operator in most cases.
CONDUIT
Conduit must be UL approved for low and high voltage.
Check national and local
codes for proper depth
10
Conduit
INSTALLATION TYPES
Identify your installation type. The installation steps in this manual will show a typical Pull-to-Open application.
SITE PREPARATION
10"
Minimum
NOTE: Weld Rebar
Behind Gate Hinges for
Maximum Strength.
Column Install
PULL-TO-OPEN
Gate Hinge
Heavy Steel Plate
for Reinforcement
(Not provided)
Heavy Steel
Bracket
(Reinforce if
necessary)
Back Steel
Bracket
(Reinforce if
necessary)
Gate Hinge
Post Install
Gate Hinge
Back Steel Plates
for Reinforcement
(Not provided)
Gate Hinge
NOTE: Weld Rebar
Behind Gate Hinges for
Maximum Strength.
Column Install
PUSH-TO-OPEN
Gate Hinge
Heavy Steel Plate
for Reinforcement
(Not provided)
Back Steel Bracket
(Reinforce if necessary)
Gate Hinge
Post Install
Gate Hinge
Gate Hinge
Control Box
Water Tight Conduit
(Not provided)
Top View
Operator
Earth Ground Rod
SINGLE GATE
!
Heavy Steel Plate for
Reinforcement (Not provided)
Control Box
Primary Operator
Earth Ground Rod
Top View
DUAL GATE
!
Water Tight Conduit (Not provided)
Secondary Operator
!
Junction Box
Shielded low
voltage wires.
11
PREPARATION
!
!
!
!
!
MOUNTING OPTIONS
MOUNTING DO's
MOUNTING OPTIONS
Weld a horizontal bar across entire gate on any installation for strength.
Make sure that the operator is mounted level or it will not function properly.
MOUNTING DON'Ts
An off-level installation may cause the gate or operator to fail prematurely.
The operator can be mounted on top of the gate frame.
DO NOT weld the crossbar on just a few pickets, or they could bend.
DO NOT install upside down.
DO NOT install on ANY pedestrian passageways, doorways, or gates.
DO NOT install on uphill or downhill gates.
DO NOT install next to sprinklers
or any area that may expose
the bottom of operator to water.
12
DO NOT over-bend the cord from the operator.
Doing this will cause the wires to eventually break.
INSTALLATION
MANUAL RELEASE + DETERMINE THE POSITION OF THE POST BRACKET
MANUAL RELEASE
Insert the key into the lock and turn it 180 degrees counterclockwise.
1
Turn the release lever 180 degrees counterclockwise. The operator is now in
2
manual mode.
If this operator is a replacement for a Miracle-One™ operator, use the existing post bracket and gate bracket. Remove the Miracle-One™ operator
from the brackets and proceed to page 15.
DETERMINE THE POSITION OF THE POST BRACKET
The measurements shown below are typical for a standard installation. Your
installation may be different. For optimal mechanical advantage the measurement
for A must be larger than the measurement for B.
Close the gate.
1
Choose a vertical mounting location for the post bracket.
2
Place a measuring tape under the center of the gate hinge point and measure
3
out 8-1/2 inches (A).
Use a screwdriver or dowel rod to temporarily mark the location of the first
4
measurement.
Measure 7-3/4 inches (B) from the previous mark.
5
Use a screwdriver to mark the location of the second measurement.
6
Align the post bracket as close as possible above the screwdriver or dowel rod
7
and tack weld the post bracket in the desired vertical position.
If your application is Push-to-Open, refer to the illustration to the right.