OPERATOR SPECIFICATIONS
Tools Needed for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Carton Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Additional Items Needed for Installation . . . . . . . . . . . . . . . . . . .3
Operator Dimensions and Specifications . . . . . . . . . . . . . . . . . . .3
UL325 Classifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
OPERATOR WARNINGS
Safety Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Suggested Entrapment Protection Device Locations . . . . . . . . . .6
Warnings and Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Warning Sign Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
INSTALLATION
Gate Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Pull-to-Open Bracket Mounting Instructions . . . . . . . . . . . . . . . .9
Push-to-Open Bracket Mounting Instructions
(for use with Accessory Kit 50-19503) . . . . . . . . . . . . . . . . .10-11
Control Box Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Control Box Mounting with U-Bolts . . . . . . . . . . . . . . . . . . . . . .12
WIRING
Connect Arm to Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Earth Ground Rod Installation . . . . . . . . . . . . . . . . . . . . . . . . . .13
Control Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
BASIC CONTROL BOARD SETUP
Set Dip Switch for Gate Type . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Programming Remote . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Wire Stop Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Optional Control Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . .18-20
Force and Timer to Close . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Program Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
OPERATION AND MAINTENANCE
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Manual Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
ACCESSORIES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
WIRING DIAGRAM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
TROUBLESHOOTING
. . . . . . . . . . . . . . . . . . . . . . . . . . .27-28
REPAIR PARTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29-30
WARRANTY POLICY AND SERVICE
. . . . . . . . . . . . . . . .32
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully.
When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your gate and/or the gate operator if you do not comply with the cautionary statements that accompany it. Read them carefully.
Mechanical
Electrical
TABLE OF CONTENTS
TABLE OF CONTENTS
WARNING
WARNING
WARNING
CAUTION
WARNING
WARNING
IMPORTANT NOTE
• BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions.
• DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician.
WARNING
TOOLS NEEDED FOR INSTALLATION
During assembly, installation and adjustment of the operator the tools listed below will be needed.
• Wrench or Socket Set
• Phillips Head Screwdriver
• C Clamps
• Level
• Small Screwdriver
• T25 Torx Head Screwdriver
HARDWARE KIT LA400 (K77-19130)
DESCRIPTION QTY
Post Bracket 1 Pull to Open Bracket 1 Hex Bolt 5/16"-18 X 1-1/2" 5 Square Neck Carriage Bolt 3/8"-16 X 6" 2 Hex Nut 3/8"-16 5 Hex Nut 5/16"-18 5 Flat Washer 5/16" 5 Flat Washer 3/8" 5 Lock Washer 5/16" 5 Lock Washer 3/8" 5 Gate Mounting Bracket 1 Hairpin Clip 4 Pin 2 Hex Bolt 3/8"-16 X 1-1/2" 1 Bolt 2-3/4" 2
CONTROL BOX LA400 (LA-CONTROL)
DESCRIPTION QTY
Control Box 1 Hardware Bag 1
MISCELLANEOUS
Linear Actuator Arm - Model LA400-1K (1) or 2 (LA400-2K) Warning Sign 2 Battery 2 Plug-In Transformer-24Vac 1
LA400-S
Extension Cable - Six Conductor 40' (12.2 m) Junction Box - IP56 1 Phillips Head Mounting Screws 4 Anchors 4 Terminal Block - Twelve Connectors 1
NOTE: Carton inventory is based on a Single Operator. For Primary (Gate 1) and Secondary (Gate 2) installation the carton inventory is doubled except for control box (1).
Main Supply (Motor) 24VDC Current Consumption 2A Power Consumption 48 Watts Battery Charger Supply 26Vac, 29VA Solar Panel Supply (Optional) 27.4V, 9W (Minimum) Maximum Gate Width 16 ft. (4.9 m) Maximum Gate Weight 550 Lbs. (249.5 kg) Protection Class NEMA 3R Travel Speed 14-18 seconds for a 90 degree opening Rated Operating Time 4 Minutes Temperature -20˚C to + 50˚C
-4˚F to + 122˚F Main Supply (Control) Dedicated Circuit 120V~/60Hz Absorbed Power 0.75 Watts Protection Fuse Gate 1 ATC 15A Protection Fuse Gate 2 ATC 15A Protection Fuse Battery ATC 20A
Permanent fasteners for warning sign
Earth Ground Rod (Optional)
Power Wire: 120Vac (Stranded Copper Wire) Power Wire: 24Vac Transformer (Stranded Copper Wire)
Wire Gauge Length Wire Gauge Length
16 100' (30 m) 14 500' (152 m) 10 1000' (305 m) 12 1000' (305 m)
OR
CARTON INVENTORY
ADDITIONAL ITEMS NEEDED FOR INSTALLATION
OPERATOR DIMENSIONS AND SPECIFICATIONS
4.00" (10.2 cm)
4.50" (11.2 cm)
.250"
(0.635 cm)
Weight: 47Lbs. (21 kg.)
32.10" (81.5 cm)
.475" DIA. (1.2 cm DIA.)
33.25" (84.5 cm)
The LA400 is intended for use with vehicular swing gates. The opener can be used in Class I, Class II and Class III applications.
CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a garage or parking area associated therewith.
CLASS II – COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units) hotel, garages, retail store or other building servicing the general public.
CLASS III – INDUSTRIAL/LIMITED ACCESS VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in a industrial location or building such as a factory or loading dock area or other locations not intended to service the general public.
SAFETY ACCESSORY SELECTION
All UL325 compliant LiftMaster gate operators will accept external entrapment protection devices to protect people from motorized gate systems. UL325 requires that the type of entrapment protection correctly matches each gate application. Below are the four types of entrapment protection systems recognized by UL325 for use on this operator.
ENTRAPMENT PROTECTION TYPES
Type A: Inherent obstruction sensing system, self-contained
within the operator. This system must sense and initiate the reverse of the gate within two seconds of contact with a solid object.
Type B1: Connections provided for a non-contact device, such as
a photoelectric eye can be used as a secondary protection.
Type B2: Connections provided for a contact sensor. A contact
device such as a gate edge can be used for secondary protection.
Type E: Built-in audio alarm. Examples include sirens, horns
or buzzers.
NOTE: UL requires that all installations must have warning signs placed in plain view on both sides of the gate to warn pedestrians of the dangers of motorized gate systems.
UL325 ENTRAPMENT PROTECTION
REQUIREMENTS
The chart above illustrates the entrapment protection requirements for each of the three UL325 classes.
In order to complete a proper installation you must satisfy the entrapment protection chart shown above. That means that the installation must have one primary means of entrapment protection and one independent secondary means of entrapment protection. Both primary and secondary entrapment protection methods must be designed, arranged or configured to protect against entrapments in both the open and close directions of gate travel.
For Example: For a slide gate system that is installed on a single-family residence (UL325 Class I) you must provide the following: As your primary type of entrapment protection you must provide Type A inherent (built into the operator) entrapment sensing and at least one of the following as your secondary entrapment protection: Type B1- Non-contact sensors such as photoelectric eyes, Type B2- Contact sensors such as gate edges.
Primary
Type
Class I and II
Class III
A, B1 or B2
A, B1,
B2 or E
A, B1 or
B2
A
UL325 Swing and Gate Barrier Installation (Arm) Operator
Secondary
Type
Gate Operator Entrapment
Protection
Class
UL325 MODEL CLASSIFICATIONS
Moving Gate Can Cause
Injury or Death
KEEP CLEAR! Gate may move at any time without prior warning.
Do not let children operate the gate or play in the gate area.
This entrance is for vehicles only Pedestrians must use separate entrance
1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application.
2. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application. Improperly designed, installed or maintained systems can create risks for the user as well as the bystander. Gate systems design and installation must reduce public exposure to potential hazards.
3. A gate operator can create high levels of force in its function as a component part of a gate system. Therefore, safety features must be incorporated into every design. Specific safety features include:
• Gate Edges • Guards for exposed rollers • Photoelectric Sensors
• Screen Mesh • Vertical Posts • Instructional and Precautionary Signage
4. Install the gate operator only when: a. The operator is appropriate for the construction and the usage class of the gate. b. All openings of a horizontal swing gate are guarded or screened from the bottom of the gate to a minimum of
4' (1.2 m) above the ground to prevent a 2-1/4" (57.15 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.
c. All exposed pinch points are eliminated or guarded, and guarding is supplied for exposed rollers.
5. The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening.
6. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
7. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
8. Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls.
9. Controls intended to be used to reset an operator after 2 sequential activations of the entrapment protection device or devices must be located in the line of sight of the gate, or easily accessible controls shall have a security feature to prevent unauthorized use.
10. All warning signs must be installed where visible, on each side of the gate.
11. For a gate operator utilizing a non-contact sensor: a. Reference owner’s manual regarding placement of non-contact sensor for each type of application. b. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still
moving.
c. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter
reachable by a moving gate or barrier.
12. For a gate operator utilizing a contact sensor such as an edge sensor: a. A hard wired contact sensor shall be located and its wiring arranged so the communication between the sensor and the gate
operator is not subject to mechanical damage.
b. A wireless contact sensor such as the one that transmits radio frequency (RF) signals to the gate operator for entrapment
protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.
c. One or more contact sensors shall be located at the leading edge, trailing edge and post mounted both inside and outside of a
vehicular horizontal slide gate. d. One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate. e. One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom
edge of a swing gate is greater than 6" (152mm) above the ground at any point in its arc of travel, one or more contact sensors
shall be located on the bottom edge.
SAFETY INSTALLATION INFORMATION
SWING GATE SYSTEM
DUAL SWING GATE SYSTEM
SUGGESTED ENTRAPMENT PROTECTION DEVICE LOCATIONS
Shadow loop should be positioned in direction of gate travel. Pull-to-open illustrated.
The shadow loop input is only active when the gate is in the fully open or fully closed positions.
STREET
Telephone Entry System
Interrupt
Loop
Photo Eye for Close Cycle
4' (1
Typical
2 m)
.
Shadow
Typical
Loop
4' (1.2 m)
Interrupt
Loop
Photo Eye for Open Cycle
COMPLEX
OR
PARKING LOT
Run Twisted Wire from Loop to Operator
Seal Loops
1-1/2" (37 mm)
Loop Wire Layer
1/4" (6 mm) or larger depending on Loop Wire size
STREET
Interrupt
Control Box
Gate 1
Shadow loop should be positioned in direction of gate travel. Pull-to-open illustrated.
The shadow loop input is only active when the gate is in the fully open or fully closed positions.
Telephone Entry System
Loop
Photo Eye for Close Cycle
2 m)
.
4' (1
Typical
Shadow
Loop
4' (1.2 m)
Typical
Gate 2
Interrupt
Loop
Junction Box
Extension Cable
Photo Eye for Open Cycle
COMPLEX OR
Run Twisted Wire from Loop to Operator
Seal Loops
1-1/2" (37 mm)
Loop Wire Layer
1/4" (6 mm) or larger depending on Loop Wire size
PARKING LOT
WARNING SIGN PLACEMENT
SAFETY PRECAUTIONS FOR SWING AND ORNAMENTAL "GRILL TYPE GATES"
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Install warning signs on EACH side of gate in PLAIN VIEW.
• Permanently secure each warning sign in a suitable manner using fastening holes.
WARNING
WARNING
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate.
• Locate entrapment protection devices to protect in BOTH the open and close gate cycles.
• Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts.
• A swinging gate shall NOT open into public access ways.
WARNING
WARNING
Moving Gate Can Cause
Injury or Death
KEEP CLEAR! Gate may move at any time without prior warning.
Do not let children operate the gate or play in the gate area.
This entrance is for vehicles only Pedestrians must use separate entrance
SINGLE GATE SETUP
INSTALLATION
Control Box with Batteries
Earth Ground Installation (Optional, See Page 13)
Antenna
12 gauge wire
8 ft. (2.4 m)
Post Bracket Assembly
Gate Operator
4-1/2' (1.4 m) Power Cable
PVC conduit (not included) to protect the power cable and low voltage wire from lawn mowers and string trimmer.
Warning Sign
Gate Bracket
DUAL GATE SETUP
Control Box with Batteries
Earth Ground Installation (Optional, See Page 13)
8 ft. (2.4 m)
Antenna
12 gauge wire
Post Bracket Assembly
Gate Operator 1
PVC conduit (not included) to protect the power cable and low voltage wire from lawn mowers and string trimmer.
4-1/2' (1.4 m) Power Cable
Gate Bracket
Gate Operator 2
Junction Box
Extension Cable
Post Bracket Assembly
C Clamp
Fence Post
Gate In OPEN Position
Horizontal Center of Gate Cross Member
3/8" Hex Bolt
3/8" Washer 3/8" Lock Washer 3/8" Nut
Pull-to-Open Bracket
Post Bracket
5/16" Washer 5/16" Lock Washer 5/16" Nut
5/16" Hex Bolt
Center of Gate Hinge
PULL-TO-OPEN INSTALLATION
Gate Post
Closed Gate
7-3/4" (19.7 cm)
7-3/4" (19.7 cm)
NOTE: You may want to drive a stake in the ground to help locate this point.
Bracket must be straight
90°
Figure 2
Figure 3
NOTE: The mounting illustrations represent a typical installation using the provided gate hardware. The gate opener may also be installed by welding it to the gate structure. For push-to-open installation order accessory kit 50-19503.
Figure 1
1. Place pull-to-open bracket on top of the post bracket. Insert 3/8" hex bolt through middle hole and secure with lock washer, flat washer and nut. Insert 5/16" hex bolt through hole in pull-to-open bracket and post bracket. Secure with washer, lock washer and nut (Figure 1).
NOTE: Do not pivot bracket, bracket must be straight or you may damage your gate, operator or gate post bracket.
2. Determine the vertical position of the gate post bracket assembly on the gate post by aligning the gate post bracket with one of the cross members of the gate. For optimal performance, align the gate post bracket to a cross member that is as close to the vertical center of the gate post as possible. Level gate post bracket assembly and temporarily secure to gate post using C clamp (Figure 2).
3. Move the gate post bracket assembly to obtain desired dimensions (Figure 3).
4. Attach operator to gate post bracket by inserting pull-to-open bracket into slot on the motor side of operator. Temporarily secure with pin (Figure 4).
Pin
Gate Post
Post Bracket
Hairpin Clip
Figure 4
PULL-TO-OPEN BRACKET MOUNTING INSTRUCTIONS
10
PUSH-TO-OPEN BRACKET MOUNTING INSTRUCTIONS (FOR USE WITH ACCESSORY KIT 50-19503)
1. Place push-to-open bracket between the two post brackets. Insert 3/8" hex bolt through middle hole and secure with lock washer, flat washer and nut (Figure 1).
2. Determine the vertical position of the gate post bracket assembly on the gate post by aligning the gate post bracket with one of the cross members of the gate (Figure 2). For optimal performance, align the gate post bracket to a cross member that is as close to the vertical center of the gate post as possible. Level gate post bracket, mark holes and temporarily secure to gate post using C clamp (Figure 2).
3. Rotate the push-to-open bracket to obtain desired dimensions (Figure 3).
Figure 1
Figure 3
5. Fasten gate bracket to the actuator side of the operator using pin. Swing operator to the desired open position (Figure 5).
6. Open gate to full open position (Do not exceed 100°). Adjust operator until it is level and position bracket against the cross member. Secure using C clamp (Figure 6).
7. Remove pins and detach operator.
8. Mark holes for post bracket assembly and gate bracket. Be sure to mark holes in the vertical center of post bracket slots.
NOTE: All four gate bracket mounting holes must be used.
9. Remove brackets from gate post and cross member.
10. Drill 13/32" holes in marked locations for gate posts and 11/32" for gate bracket.
11. Secure gate posts bracket assembly to gate post using 3/8" bolts, lock washer, flat washer and nuts. Secure gate bracket to cross member using 5/16" bolts, lock washer, flat washer and nuts.
12. Reattach operator to gate using pins and hairpin clips.
NOTE: After final limit adjustments (page 21) the gate can be opened slightly further by increasing the distance between center of gate hinge and the gate bracket by 1" (25.4 mm). Do not move the post bracket assembly.
Gate In OPEN Position
Gate Bracket
C Clamp
Operator MUST be level
Horizontal Center of Gate Cross Member
Figure 6
Pin
Gate Bracket
Actuator Side
Hairpin Clip
Figure 5
Post Bracket Assembly
C Clamp
Fence Post
Gate In CLOSED Position
Horizontal Center of Gate Cross Member
Figure 2
5/16" Hex Bolt
3/8" Hex Bolt
Post Bracket
Push-to-Open Bracket
Post Bracket
3/8" Flat Washer
3/8" Lock Washer
3/8" Nut
Center of Gate Hinge
7-3/4" (19.7 cm)
90˚
7-3/4" (19.7 cm)
Special Post Pivot Bracket for
Push-to-Open Installation
Loading...